The Enviro Cabello is a discontinued wood-burning fireplace insert made in two sizes, the Cabello 1200 and 1700, and Enviro lists both of its owner's manuals as archived. The last edition is C-14580, the 2015 EPA manual listed from May 2015 to May 2020, a free PDF from enviro.com that covers both sizes. Cabello parts are still sold here, and the rating label with the serial number is on the right side of the insert, behind the surround.
Both Cabello owner's manuals Enviro still publishes, the factory parts list with part numbers (air tubes, baffles, bricks, glass, gasket, fan and the cast surround pieces), key specs for the 1200 and 1700, and answers to common wood-burning questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the Cabello, but we still sell its parts.
Last updated · From Enviro docs C-14580 and C-13851 rev R01 · Answers drafted from the manuals; staff review pending
Cabello 1200 FPI (1200-C)
The smaller insert: a 1.85 cubic foot firebox for logs of about 16 inches, secondary air tubes A, D and E, and the 1200 ceramic baffle set. Both manuals cover it; C-14580 is the edition certified to the 2015 EPA wood heater limits.
Manuals: C-14580, C-13851
Cabello 1700 FPI (1700-C)
The larger insert: a 2.50 cubic foot firebox for logs of about 18 inches, secondary air tubes A, B and C, and the 1700 ceramic baffle set. Same cast surround, door, fan and controls as the 1200, and covered by the same two manuals.
Manuals: C-14580, C-13851
Find your model and serial number: The rating label, with the model and serial number, is on the right side of the insert, behind the surround. (Enviro C-14580, p. 11)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro Cabello is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro Cabello parts.
Can't open a link? Enviro lists every version on its manuals pages: Enviro Cabello manuals, Enviro legacy manuals.
From the parts lists in the Enviro Cabello manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | 120 ceramic fan temperature sensor (all models) | EC-001 | $77.79 CAD → |
| 2 | FPI burner switch | EC-026 | $30.00 CAD → |
| 3 | Wood insert fan controller (75 V), 115 V | EC-039 | Request it |
| 4 | Domestic power cord (115 V) | EC-042 | $55.38 CAD → |
| 5 | Heyco strain relief | EC-044 | $73.29 CAD → |
| 6 | Woodstove door gasket (7 ft) | EF-168 | $78.00 CAD → |
| 7 | EFW glass with tape | 10-000 | $249.09 CAD → |
| 8 | 1200 and 1700 front secondary air tube A | 50-1099 | $102.22 CAD → |
| 9 | 1700 rear secondary air tube C | 50-1100 | $102.22 CAD → |
| 10 | 1700 middle secondary air tube B | 50-1101 | $102.22 CAD → |
| 11 | 1200 rear secondary air tube E | 50-1102 | $102.22 CAD → |
| 12 | 1200 middle secondary air tube D | 50-1103 | $102.22 CAD → |
| 13 | Pumice bricks, 3 x 9 | 50-1104 | Request it |
| 14 | Pumice bricks, 4.5 x 9 | 50-1105 | Request it |
| 15 | 1200/1700 left shield assembly | 50-1144 | $115.00 CAD → |
| 16 | 1200/1700 right shield assembly | 50-1145 | $138.00 CAD → |
| 17 | 1200 ceramic baffle, left and right set | 50-1146 | $120.00 CAD → |
| 18 | 1700 ceramic baffle, left and right set | 50-1147 | $208.00 CAD → |
| 19 | 1200/1700 FPI insert flue collar assembly | 50-1148 | $146.00 CAD → |
| 20 | Wood ceramic flue gasket | 50-1413 | $82.16 CAD → |
| 21 | FPI angled flue collar | 50-1565 | $127.35 CAD → |
| 22 | Wood door glass retainer kit (with screws) | 50-1122 | $74.00 CAD → |
| 23 | Boston door handle, complete | 50-2393 | $164.48 CAD → |
| 24 | Cabello FPI replacement fan assembly | 50-2669 | $206.67 CAD → |
| 25 | Cabello door assembly (no handle) | 50-2670 | Request it |
| 26 | Cabello cast top, right (PD) | 50-2671 | Request it |
| 27 | Cabello cast top, left (PD) | 50-2672 | Request it |
| 28 | Cabello cast keystone (PD) | 50-2673 | Request it |
| 29 | Cabello cast top (PD) | 50-2674 | Request it |
| 30 | Cabello cast side, left (PD) | 50-2675 | Request it |
| 31 | Cabello cast side, right (PD) | 50-2676 | Request it |
| 32 | Cabello cast bottom (PD) | 50-2677 | Request it |
| 33 | Cabello cast surround, complete (PD) | 50-2678 | Request it |
| 34 | 1200/1700 Cabello oversize filler panel (36" x 46")option | 50-2613 | Request it |
| 35 | Cabello damper rod with knob and nut | 50-2770 | $76.00 CAD → |
| – | Cabello owner's manual | 50-2627 | Request it |
On the rating label, which is on the right side of the insert, behind the surround. The label has a serial number box and tick boxes for the Cabello 1200 FPI and Cabello 1700 FPI, so it also tells you which size you have. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-14580, p. 11; C-14580, p. 32; C-14580, p. 36
The Cabello is discontinued and Enviro lists both of its owner's manuals as archived; each covers the 1200 and the 1700. C-14580, listed May 4, 2015 to May 5, 2020, is the edition for inserts certified to the 2015 EPA wood heater limits. C-13851 R01, listed April 25, 2013 to May 4, 2015, is the earlier edition, written to the EPA limits for heaters sold after July 1, 1990. Both print the same parts list: page 31 of C-14580 and page 30 of C-13851.
Source: Enviro C-14580, p. 1; C-13851, p. 1; C-14580, p. 31; C-13851, p. 30
Pull the air control all the way out, build a small fire of crumpled plain newspaper and dry kindling directly on the firebricks, light it, and leave the door slightly open while the kindling and small pieces of seasoned wood catch. Once the wood is burning and the smoke has reduced, close the door fully, add larger pieces and set the air control. Never use a grate, and never use gasoline, kerosene, lighter fluid or similar liquids to start or freshen a fire. On the first burn or two the paint cures and smells, so open a door or window.
Source: Enviro C-14580, p. 8; C-14580, p. 7; C-14580, p. 6; C-14580, p. 11; C-14580, p. 5
With the air control rod on the right side of the insert: pull it out for more air and a bigger fire, push it in for less. Secondary air flows on its own through the tubes at the top of the firebox, just below the baffles. Pull the rod all the way out to start the fire, then adjust it once the fire is established; Enviro recommends a low to medium setting for best efficiency, and the lower the setting, the longer the wood lasts. Opening it fully before you open the door to reload lets the chimney carry the extra smoke away. When shutting down, open it fully so the chimney stays hot as long as possible, since a cold chimney creates creosote. The minimum low burn rate is set at the factory and must not be altered.
Source: Enviro C-14580, p. 11; C-14580, p. 8; C-14580, p. 7; C-14580, p. 4
Normally three or four logs give heat for several hours. Using more than five at a time can overfire the stove, and Enviro says a maximum of four is usually enough. Keep the logs a few inches below the air tubes at the top of the firebox, because logs touching the tubes can damage them. You are overfiring if the heater or chimney connector glows, or if a thermometer on the stove top reads over 550°F; overfiring and overloading void the warranty. The most heat for the least fuel comes with a stove top temperature between 250°F (120°C) and 550°F (290°C).
Source: Enviro C-14580, p. 7
Natural wood only, and dry: seasoned wood has been dried for one year in a well-ventilated, sheltered place. Freshly cut wood is about 50% moisture (a 10 pound, 4.5 kg log holds 5 pounds, 2.3 kg, of water), and damp or wet wood is a main reason a fire won't light; wet, unseasoned wood also builds creosote. Hardwood and softwood both burn well; hardwood is denser and burns a little slower and longer. Logs of about 16" suit the 1200 (it takes up to 18") and about 18" the 1700 (up to 20"). Never burn treated wood, coal, charcoal, garbage, solvents, coloured paper or trash.
Source: Enviro C-14580, p. 8; C-14580, p. 9; C-14580, p. 6; C-14580, p. 3
Slow fires give off tar and vapours that condense in a cool chimney as creosote, which burns extremely hot if it ignites. Enviro says to inspect the chimney connector and chimney biweekly during the heating season and remove creosote once it has built up to 3 mm or more. At the end of each heating season, clean the chimney and the smoke pipe, clean any soot above the top baffle, replace a badly corroded secondary air tube, and replace worn door gaskets and broken bricks. Clean the rain cap and spark arrestor regularly too.
Source: Enviro C-14580, p. 6; C-14580, p. 9
Call the fire department, close the draft fully, and check the flue pipes, chimney, attic and roof for anything hot enough to catch fire. Do not use the insert again until you are certain the chimney and its lining are undamaged.
Source: Enviro C-14580, p. 6
Ashes left two or three inches deep on the bottom of the firebox tend to burn themselves up. When you do remove them, wait until the fireplace has completely cooled, put them in a metal container with a tight-fitting lid, and keep the closed container on a noncombustible floor or on the ground, away from anything combustible, until final disposal. Keep the ash lip clear so the door seals.
Source: Enviro C-14580, p. 5; C-14580, p. 7
As the door gasket compresses against the firebox, the latch may need adjusting to keep a tight seal; signs are a handle that feels loose when closed, or wood burning faster than normal. Replace worn door gaskets as needed (the parts list gasket is EF-168, 7 ft), and never run the insert with a gasket missing or damaged.
Source: Enviro C-14580, p. 29; C-14580, p. 6; C-14580, p. 31; C-14580, p. 3
A hot insert with a good draft keeps the glass clean through its air-wash system, and soot at the start of a fire burns off once the firebox heats up. If you must clean it, use a soft cloth with no abrasive, only when the unit is cold. Dirty glass usually means too little fuel to get the stove hot, green or wet wood, the air turned down too far, or a weak chimney draw. If the glass cracks during a fire, do not open the door until the fire is out, and do not use the insert until the glass is replaced. Only factory glass is allowed: Neoceram 5 mm, 16.61" x 10.63", bought from an Enviro dealer (glass with tape, part 10-000). Wear gloves when handling a damaged glass door.
Source: Enviro C-14580, p. 9; C-14580, p. 7; C-14580, p. 5; C-14580, p. 31
The fan has a three-position switch (manual, off and auto) and a rotary speed dial, both at the lower left side of the insert; the dial turns OFF, HIGH, LOW. In auto, with the dial on, the fan starts once the stove reaches operating temperature (roughly 25 minutes from a cold start) and its temperature sensor shuts it off when the unit cools. Manual turns it on at once. Plug it into a grounded three-prong outlet, route the cord along the floor in front of the surround (never beneath the heater), and do not oil the fan bearings.
Source: Enviro C-14580, p. 5; C-14580, p. 25