Manuals & parts · Wood-burning fireplace insert (discontinued)
Quick answer
The Enviro Venice is a discontinued wood-burning fireplace insert made in two sizes, the Venice 1200 and 1700, and Enviro lists all four of its owner's manuals as archived. The last edition is C-14578, the 2015 EPA manual listed from May 2015 to May 2020, a free PDF from enviro.com that covers both sizes. Venice parts are still sold here, and the rating label with the serial number is on the side of the insert, behind the right shroud.
All four Venice owner's manuals Enviro still publishes, the factory parts list with part numbers (air tubes, ceramic baffles, bricks, glass, gasket, fan, shrouds and the cast top), key specs for the 1200 and 1700, and answers to common wood-burning questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the Venice, but we still sell its parts.
Last updated · From Enviro docs C-14578, C-11891 and C-13824 · Answers drafted from the manuals; staff review pending
Venice 1200 FPI (1200-V)
The smaller insert: a 1.85 cubic foot firebox for logs of about 16 inches, secondary air tubes A, D and E, and the 1200 C-Cast ceramic baffle. All four manuals cover it; C-14578 is the edition certified to the 2015 EPA wood heater limits, the older three to the limits for heaters sold after July 1, 1990.
Manuals: C-14578, C-13824, C-12199, C-11891
Venice 1700 FPI (1700-V)
The larger insert: a 2.5 cubic foot firebox for logs of about 18 inches, secondary air tubes A, B and C, and the 1700 C-Cast ceramic baffle. Same door, fan, shrouds, cast top and controls as the 1200, and covered by the same four manuals.
Manuals: C-14578, C-13824, C-12199, C-11891
Find your model and serial number: The rating label, with the model and serial number, is on the side of the insert, behind the right shroud. (Enviro C-14578, p. 11)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro Venice is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro Venice parts.
Can't open a link? Enviro lists every version on its manuals pages: Enviro Venice manuals, Enviro legacy manuals.
From the parts lists in the Enviro Venice manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | 120F (49C) ceramic fan temperature sensor | EC-001 | $77.79 CAD → |
| 2 | Insert burner switch | EC-026 | $30.00 CAD → |
| 3 | FPI fan controller, 115V | EC-039 | Request it |
| 4 | Domestic power cord, 115V | EC-042 | $55.38 CAD → |
| 5 | Heyco strain relief | EC-044 | $73.29 CAD → |
| 6 | Wood door gasket | EF-168 | $78.00 CAD → |
| 7 | Glass with tape | 10-000 | $249.09 CAD → |
| 8 | Enviro logo gel decal | 50-322 | Request it |
| 9 | 1200 and 1700 front secondary air tube A | 50-1099 | $102.22 CAD → |
| 10 | 1700 rear secondary air tube C | 50-1100 | $102.22 CAD → |
| 11 | 1700 middle secondary air tube B | 50-1101 | $102.22 CAD → |
| 12 | 1200 rear secondary air tube E | 50-1102 | $102.22 CAD → |
| 13 | 1200 middle secondary air tube D | 50-1103 | $102.22 CAD → |
| 14 | Pumice brick, 3" x 9" | 50-1104 | Request it |
| 15 | Pumice brick, 4.5" x 9" | 50-1105 | Request it |
| 16 | Glass retainer kit (with screws) | 50-1122 | $74.00 CAD → |
| 17 | 1200 and 1700 left shield assembly | 50-1144 | $115.00 CAD → |
| 18 | 1200 and 1700 right shield assembly | 50-1145 | $138.00 CAD → |
| 19 | 1200 C-Cast ceramic baffle (1 piece) | 50-1146 | $120.00 CAD → |
| 20 | 1700 C-Cast ceramic baffle (1 piece) | 50-1147 | $208.00 CAD → |
| 21 | 1200 and 1700 insert flue collar assembly | 50-1148 | $146.00 CAD → |
| 22 | 1200 and 1700 cast latch | 50-1381 | Request it |
| 23 | 1200 and 1700 ceramic flue gasket | 50-1413 | $82.16 CAD → |
| 24 | Kodiak/Venice FPI angled flue collar | 50-1565 | $127.35 CAD → |
| 25 | 1200 and 1700 insert replacement fan | 50-2204 | $190.77 CAD → |
| 26 | Fireplace insert surround panel | 50-1961 | Request it |
| 27 | Fireplace insert base shelf | 50-1986 | Request it |
| 28 | 1200V and 1700V cast top | 50-2000 | Request it |
| 29 | 1200V and 1700V left fan shroud | 50-2016 | Request it |
| 30 | 1200V and 1700V right fan shroud | 50-2017 | Request it |
| 31 | Door handle, complete | 50-2018 | Request it |
| 32 | Door, complete | 50-2019 | Request it |
| 33 | 1200V and 1700V left fan shroud, complete | 50-2169 | Request it |
| – | Venice owner's manual | 50-2034 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 25 | 1200 and 1700 insert replacement fan (2009 list) | 50-1711 | Request it |
| 26 | Woodstove pokeroption | 50-1816 | Request it |
| 34 | 1200V and 1700V left fan shroud, complete (2009 list) | 50-2020 | Request it |
On the rating label, which is on the side of the insert, behind the right shroud. The sample label in the manual has a serial number box and tick boxes for the Venice 1200 FPI and Venice 1700 FPI (the same label also covers the Boston and Kodiak), so it also tells you which size you have. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-14578, p. 11; C-14578, p. 27; C-14578, p. 32
The Venice is discontinued and Enviro lists all four of its owner's manuals as archived; each covers the 1200 and the 1700. C-14578, listed May 5, 2015 to May 5, 2020, is the edition for inserts certified to the 2015 EPA wood heater limits. C-13824 (May 6, 2013 to May 5, 2015), C-12199 (December 1, 2010 to March 6, 2013) and C-11891 (June 2, 2009 to December 1, 2010) are the earlier editions, written to the EPA limits for heaters sold after July 1, 1990. All four print a parts list; the 2009 edition, C-11891, gives an earlier replacement fan (50-1711) and left fan shroud (50-2020) than the later lists.
Source: Enviro C-14578, p. 1; C-13824, p. 1; C-14578, p. 28; C-11891, p. 27
Pull the air control all the way out, build a small fire of crumpled plain newspaper and dry kindling directly on the firebricks, light it, and leave the door slightly open while the kindling and small pieces of seasoned wood catch. Once the wood is burning and the smoke has reduced, close the door fully, add larger pieces and set the air control. Never use a grate, and never use gasoline, kerosene, charcoal lighter fluid or similar liquids to start or freshen a fire. Always open the door slowly so smoke is not drawn into the room. On a first start the chimney, bricks and steel are cold and usually need several hours on a fairly high burn to heat and dry out, and the paint smells for the first burn or two as it cures, so open a door and a window.
Source: Enviro C-14578, p. 8; C-14578, p. 7; C-14578, p. 6; C-14578, p. 11; C-14578, p. 5
One rod on the right side of the insert controls the air wash and pilot air that feed the fire: pull it out for more air and a bigger fire, push it in for less. Secondary air flows on its own through the tubes at the top of the firebox, just below the baffles. Pull the rod all the way out to start the fire; if it is closed at start-up the fire burns very slowly and can soot the insert. Once the fire is established, set it for the heat you want, and open it fully before you open the door to reload so the chimney carries the extra smoke away. When shutting down, open it fully so the chimney stays hot as long as possible, since a cold chimney creates creosote. The minimum low burn rate is set at the factory and must not be altered.
Source: Enviro C-14578, p. 11; C-14578, p. 7; C-14578, p. 4
Normally three or four logs give heat for several hours. Using more than five at a time can overfire the insert, and Enviro says a maximum of four is usually enough. The air tubes at the rear of the firebox sit lower, so keep the logs a few inches from the lowest point of the firebox top: logs touching the tubes can damage them. You are overfiring if the heater or chimney connector glows, or if a thermometer on the stove top reads over 550°F; overfiring and overloading void the warranty. The most heat for the least fuel comes with a stove top temperature between 250°F (120°C) and 550°F (290°C).
Source: Enviro C-14578, p. 7; C-14578, p. 6
Natural wood only, and dry: seasoned wood has been dried for one year in a well-ventilated, sheltered place, split and stacked so air reaches every part. Freshly cut wood is about 50% moisture (a 10 pound, 4.5 kg log holds 5 pounds, 2.3 kg, of water), damp or wet wood is a main reason a fire won't light, and wet, unseasoned wood builds creosote. Hardwood and softwood both burn well; hardwood is denser and burns a little slower and longer, and air-dried seasoned hardwood gives higher efficiency and lower emissions. Cut logs to fit front to back: about 16" for the 1200 (it takes up to 18") and about 18" for the 1700 (up to 20"). Never burn treated wood, coal, charcoal, garbage, solvents, coloured paper or trash.
Source: Enviro C-14578, p. 8; C-14578, p. 9; C-14578, p. 6; C-14578, p. 3
Slow fires give off tar and vapours that condense in a cool chimney as creosote, which burns extremely hot if it ignites. Enviro says to clean the chimney a minimum of twice a year and as required, and to inspect the smoke pipe and chimney biweekly during the heating season and remove any creosote build-up. At the end of each heating season, clean the chimney and the smoke pipe, take out, clean and refit the top baffle bricks if soot has built up above them, replace a badly eroded secondary air tube, and replace worn door gaskets and broken bricks. Clean the rain cap and especially the spark arrestor regularly too.
Source: Enviro C-14578, p. 3; C-14578, p. 6; C-14578, p. 9
Call the fire department, close the draft fully, and check the flue pipes, chimney, attic and roof for anything hot enough to catch fire. Do not use the insert again until you are certain the chimney and its lining are undamaged.
Source: Enviro C-14578, p. 6
The Venice has no ash drawer, so ashes are scooped out. Ashes left two or three inches deep on the firebox floor tend to burn themselves up. When you do remove them, put them in a metal container with a tight-fitting lid and keep the closed container on a noncombustible surface, well away from the house and anything combustible, until they are completely cool. Keep the ash lip clear so the door seals. Small amounts of cold wood ash can go in the garden or compost.
Source: Enviro C-14578, p. 5; C-14578, p. 3; C-14578, p. 7
As part of the end-of-season maintenance, replace a worn door gasket as needed (the parts list gasket is the wood door gasket, EF-168). The door must be tightly closed whenever the insert is burning. If a gasket is missing or damaged, or the door glass is broken, Enviro says the insert must be repaired by a qualified service technician before you use it again. Keep the ash lip clear of embers and ash, because closing the door on debris can spoil the gasket seal. The Venice manual does not give a gasket or latch adjustment procedure; the cast latch is part 50-1381.
Source: Enviro C-14578, p. 6; C-14578, p. 3; C-14578, p. 7; C-14578, p. 28
A hot insert with a good draft keeps the glass clean through its air-wash system, and soot at the start of a fire burns off once the firebox heats up. If you must clean it, use a soft cloth with no abrasive, only when the unit is cold. Dirty glass usually means too little fuel to get the insert hot, green or wet wood, the air turned down too far, or a weak chimney draw. Never strike or slam the door or let burning wood rest against the glass. If it cracks during a fire, do not open the door until the fire is out, and do not use the insert until the glass is replaced; the safety section says a qualified service technician must repair broken glass. Only factory glass is allowed: Neoceram 5 mm, 16.61" x 10.63", bought from an Enviro dealer (glass with tape, part 10-000; glass retainer kit, 50-1122). Wear gloves when handling a damaged glass door.
Source: Enviro C-14578, p. 9; C-14578, p. 7; C-14578, p. 5; C-14578, p. 3; C-14578, p. 28
Sale price $73.29 CAD Regular price $80.99 CAD