Enviro Parts Only / One brand, every part
Search by Model / Find your exact unit
14-Day Returns / See our returns policy
Expert Advice / From people who care
Enviro Fireplace PartsEvery Enviro part, the right fit.
SupportWe're here to helpTrack OrderCheck status
Find My PartFind the right fit
  • Models
  • Find My Part
  • Manuals
  • Contact
Menu
  • Models
  • Find My Part
  • Manuals
  • Contact
Enviro Fireplace PartsEvery Enviro part, the right fit.
Find My Part Request a Part
Enviro Fireplace Parts

Every Enviro part, the right fit.

Get fitment tips, restock alerts, and Enviro parts news — straight to your inbox.

Shop

  • Shop by Model
  • Shop by Category
  • All Parts

Parts by Appliance

  • Wood Stove Parts
  • Gas Fireplace Parts
  • Pellet Stove Parts

Help & Support

  • Find My Part
  • Request a Part
  • Help Centre
  • Shipping & Delivery
  • Returns & Refunds
  • Warranty

Company

  • About Us
  • Contact Us
  • Blog

© 2026 Enviro Fireplace Parts. All rights reserved.

Enviro Fireplace Parts is operated by Friendly Fires Inc. · (705) 741-1900

PrivacyTermsAccessibility
  • Home
  • Models
  • Parts
  • Support
  • Cart
  1. Home
  2. Manuals
  3. Enviro Berkeley

Manuals & parts · Direct vent freestanding gas stove

Enviro Berkeley Manuals

Quick answer

The current Enviro Berkeley manuals are C-14872 (BRK, the millivolt Berkeley-Nova) and C-14873 (BRKI, the Berkeley-IPI and Berkeley-D), both free PDFs from enviro.com. A Berkeley-Nova has a pilot you light by hand with the gas control knob and piezo ignitor, while a Berkeley-IPI lights itself from the Proflame 2 remote. The rating label with the model and serial number is on a plate hanging on the back of the stove.

Owner's manuals for the Enviro Berkeley cast iron freestanding gas stove listed by Enviro since 2016, millivolt and IPI, with the factory parts lists and part numbers, key specs and answers to common Berkeley questions, each taken from the official Enviro manual with the page number.

Last updated Nov 25, 2026 · From Enviro docs C-14872 rev R2 and C-14873 rev R2 · Answers drafted from the manuals; staff review pending

Shop Enviro Berkeley partsGet the manual

Which Enviro Berkeley do I have?

Berkeley-Nova (BRK, millivolt)

S.I.T. Nova millivolt valve behind the front valve access door. You light the pilot by hand with the gas control knob and piezo ignitor, then run the burner from a burner switch and a HI/LO knob; the convection fan has its own control knob. It can also be run from an optional remote or wall thermostat. Manuals listed from June 2016; the R2 edition from June 2020.

Manuals: C-14872

Berkeley-IPI (BRKI)

Intermittent pilot ignition with an S.I.T. 885 valve and the Proflame 2 remote and integrated fireplace controller (IFC), which light the pilot and burner for you. The remote also runs six flame levels, a room thermostat, six fan speeds and split flow, which shuts off the front section of the burner. Manuals listed from June 2016; the R2 edition from December 2021, which lists a 2021 IPI pilot assembly.

Manuals: C-14873

Berkeley-D

The Berkeley-IPI body with the Dexen control system. The BRKI manual covers it, but sends owners to the separate Dexen user manual supplied with the stove for remote operation, wiring, troubleshooting and Dexen-specific replacement parts. Covered from the R2 edition (December 2021).

Manuals: C-14873

Find your model and serial number: The rating label and lighting instructions are on a plate hanging on the back of the unit. (Enviro C-14872, p. 6)

Diagram of an Enviro Berkeley showing where the rating label with the model and serial number is: The rating label and lighting instructions are on a plate hanging on the back of the Berkeley.

Enviro Berkeley parts from the manual, sold here

Enviro Berkeley/S40 Firebox Air Restrictor (50-3231) — Enviro Fireplace Parts

Enviro Berkeley/S40 Firebox Air Restrictor (50-3231)

Sale price $46.67 CAD Regular price $51.99 CAD

Enviro Ceramic Fan Sensor (EC-001) — Enviro Fireplace Parts

Enviro Ceramic Fan Sensor (EC-001)

Sale price $77.79 CAD Regular price $85.99 CAD

Enviro 50-2493 Replacement Blower — Enviro Fireplace Parts

Enviro Replacement Blower - Many Models (50-2493)

Sale price $243.33 CAD Regular price $267.99 CAD

Enviro Blower with Mounting Bracket - Berkeley/Q1/Q2/Q3/S20/S40 (50-3836) — Enviro Fireplace Parts
Where to find the Enviro Berkeley rating label. Our diagram, based on Enviro C-14872 p. 6.
Chart of Enviro Berkeley versions: Berkeley-Nova (BRK, millivolt), Berkeley-IPI (BRKI), Berkeley-D, with what sets each one apart.
Enviro Berkeley versions at a glance. Our chart, from the Enviro manuals listed below.

Enviro Berkeley owner's and installation manuals

Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.

  • BRKI Owner's Manual R2 (Berkeley-IPI / Berkeley-D)

    C-14873 rev R2 · Dec 1, 2021 – Current · 44 pages · Current

    PDF
  • BRK Owner's Manual R2 (Berkeley-Nova, millivolt)

    C-14872 rev R2 · Jun 1, 2020 – Current · 44 pages · Current

    PDF
Older Enviro Berkeley manuals (2)
  • BRKI Owner's Manual (Berkeley-IPI)

    C-14873 · Jun 27, 2016 – Dec 1, 2021

    PDF
  • BRK Owner's Manual (Berkeley-Nova, millivolt)

    C-14872 · Jun 27, 2016 – May 31, 2020

    PDF

Can't open a link? Enviro lists every version on its manuals pages: Enviro Berkeley manuals.

Enviro Berkeley parts list, with part numbers

From the parts lists in the Enviro Berkeley manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.

Berkeley-Nova (BRK, millivolt) (Enviro C-14872, p. 38)

RefPartPart #Our store
1Door latch mechanism with spring (set of 2)50-1285Request it
2Firebox air restrictor50-3231$46.67 CAD →
3Pilot shield50-3232Request it
4120 ceramic fan temperature sensorEC-001$77.79 CAD →
5Convection fan only50-2493$243.33 CAD →
–Convection fan with mount50-3836$286.67 CAD →
6FPI fan controller (69.5 V), 115 V, with FS knobEC-039A$119.51 CAD →
7Fan controller knob with decalEC-040$8.85 CAD →
8S.I.T. piezo ignitorEC-023$44.25 CAD →
9FPI burner switchEC-026$30.00 CAD →
10Control panel and decal50-2989Request it
11PSE pilot assembly, standing pilot50-2513Request it
12S.I.T. Nova valve, convertible50-1421Request it
13Heyco strain reliefEC-044$73.29 CAD →
14Domestic power cord (115 V)EC-042$55.38 CAD →
15Log set (9 pieces)option50-3234Request it
16Ceramic burner assembly50-3233$670.77 CAD →
17Front door glass with gasket (16.875 x 21.0625 in)50-3235$286.60 CAD →
18Front door complete50-3236Request it
19Side door glass with gasket (15.875 x 11.625 in)50-3237$188.36 CAD →
20Side door complete50-3238Request it
21Ceramic fluted liner (1 piece)option50-3239$261.42 CAD →
22Replacement safety screen, front50-3243Request it
23Replacement safety screen, side50-3244$201.96 CAD →
24B-vent drafthood adaptoroption50-3667Request it
25Vent collar cover50-3245Request it
26Termination guard50-3266$202.50 CAD →
27Berkeley owner's manual50-3259Request it
–Conversion kit, LP to NG (Nova)option50-3261$99.28 CAD →
–Conversion kit, NG to LP (Nova)option50-3262$78.33 CAD →
–Metallic black touch-up paint, 12 oz canPAINT-12-MBRequest it

Berkeley-IPI / Berkeley-D (Enviro C-14873, p. 40)

RefPartPart #Our store
1Door latch mechanism with spring (set of 2)50-1285Request it
2Firebox air restrictor50-3231$46.67 CAD →
3Pilot shield50-3232Request it
4Convection fan only50-2493$243.33 CAD →
–

Berkeley cast iron castings (all versions) (Enviro C-14872, p. 40)

RefPartPart #Our store
28Cast top, painted50-3246$226.08 CAD →
–Cast top, enamelled Antique Chestnut50-3247Request it
30Cast front, painted50-3248Request it
–Cast front, enamelled Antique Chestnut50-3249 →

Enviro Berkeley questions, answered from the manual

Where is the serial number on an Enviro Berkeley?

On the rating label. The rating label and the lighting instructions are on a plate hanging on the back of the stove, on both the millivolt Berkeley-Nova and the Berkeley-IPI. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual. Enviro asks for the appliance serial number on warranty claims, and the warranty registration has to be submitted within 90 days of purchase.

Source: Enviro C-14872, p. 6; C-14873, p. 6; C-14872, p. 44; C-14872, p. 43

Which Berkeley manual do I need?

Check the model on the rating label. BRK is the millivolt Berkeley-Nova: you light its pilot by hand with the gas control knob and piezo ignitor, and you run the burner with a burner switch and a HI/LO knob. Its manual is C-14872. BRKI is the Berkeley-IPI, which lights itself when you press ON/OFF on the Proflame 2 remote; its manual is C-14873, which also covers the Berkeley-D. A Berkeley-D owner also needs the separate Dexen user manual supplied with the stove for remote operation, wiring, troubleshooting and Dexen parts. Older Berkeleys are covered by the archived first editions of both manuals, listed from June 2016; the documents list above shows the dates.

Source: Enviro C-14872, p. 1; C-14872, p. 7; C-14872, p. 9; C-14872, p. 41; C-14872, p. 44; C-14873, p. 1; C-14873, p. 7; C-14873, p. 9; C-14873, p. 40; C-14873, p. 44

How do I light the pilot on a millivolt Berkeley-Nova?

The Berkeley-Nova has a pilot you light by hand, following the lighting label. Use only your hand on the gas control knob: if it will not push in or turn by hand, don't try to repair it, call a qualified service technician. If the knob does not pop up when released, stop and call your service technician or gas supplier right away. The valve has a lockout that will not let the pilot relight until the thermocouple has cooled. If the pilot will not stay lit after several tries, turn the knob clockwise to OFF and call your service technician or gas supplier. If you smell gas, don't light anything and follow the gas safety steps on the label.

  1. Set the thermostat to its lowest setting and turn off all electric power to the stove. (C-14872, p. 7)
  2. Open the front control panel and turn the gas control knob clockwise to OFF. (C-14872, p. 7)
  3. Open the door and wait five minutes to clear out any gas. Close the door and smell for gas, including near the floor. If you smell gas, stop. (C-14872, p. 7)
  4. The pilot is near the center rear of the firebox. Turn the gas control knob counter-clockwise to PILOT, push it in fully and hold it. (C-14872, p. 7)
  5. While holding the knob in, press the piezo ignitor several times until the pilot lights. Keep the knob pushed in for about 30 seconds, then release it and check that the flame fully engulfs the thermocouple. (C-14872, p. 8)
  6. Turn the knob counter-clockwise to ON. Flip the burner switch at the top right rear of the stove to ON and set the HI/LO knob to the flame height you want. (C-14872, p. 9)
  7. Close the front control panel, turn the electric power back on and set the thermostat. (C-14872, p. 7)

Source: Enviro C-14872, p. 7; C-14872, p. 8; C-14872, p. 9

How do I turn on a Berkeley-IPI with the Proflame 2 remote?

The Berkeley-IPI lights itself. Don't try to light the pilot by hand. Press ON/OFF on the remote; the controller (IFC) beeps once, lights the pilot and then the main burner, which takes about 10 seconds. The IFC makes one ignition attempt lasting about 60 seconds, and locks out if it senses no flame. If the stove will not operate, follow the steps to turn off the gas and call your service technician or gas supplier. A Berkeley-D is run from the Dexen remote instead, described in the separate Dexen user manual.

  1. Turn off all electric power to the stove, wait five minutes to clear out any gas, then smell for gas, including near the floor. If you smell gas, stop and follow the safety steps on the lighting label. (C-14873, p. 7)
  2. Turn the electric power back on. (C-14873, p. 7)
  3. Press ON/OFF on the remote. ON shows on the remote display and the stove beeps to confirm. (C-14873, p. 7)
  4. The IFC lights the pilot first, then the main burner. This should take about 10 seconds. (C-14873, p. 11)
  5. To turn it off, press ON/OFF again. The IFC beeps once and the burner turns off, along with the pilot unless the stove is in continuous pilot mode. (C-14873, p. 12)

Source: Enviro C-14873, p. 7; C-14873, p. 9; C-14873, p. 11; C-14873, p. 37

My Berkeley-IPI remote stopped working. How do I re-sync it?

Check the simple causes first: the remote may be too far from the stove, or its batteries may be low or dead. A battery icon on the remote display means its three AAA batteries are low. If the IFC does not beep when you press ON/OFF, its four AA backup batteries are low. After changing batteries, re-sync the remote to the IFC with the reset button. The replacement Proflame 2 transmitter is part 50-3265. On a millivolt Berkeley-Nova the remote is an option: leave the burner switch in the remote/thermostat position and follow the remote's own instructions.

  1. Turn off the main gas supply to the stove before you remove or reinsert the batteries in the IFC battery holder. (C-14873, p. 9)
  2. Fit four AA batteries in the IFC battery holder, matching the polarity marked on the holder. (C-14873, p. 11)
  3. Press the reset button marked SW1 on the IFC. It beeps three times when it is ready to sync. (C-14873, p. 11)
  4. Fit three AAA batteries in the battery bay on the base of the remote. (C-14873, p. 11)
  5. Press ON on the remote. The IFC beeps four times to confirm it has accepted that remote's code. (C-14873, p. 11)

Source: Enviro C-14873, p. 14; C-14873, p. 38; C-14873, p. 40; C-14872, p. 8; C-14872, p. 37

What do the flashing lights on the Berkeley-IPI controller mean?

The LED on the Proflame 2 controller (IFC) blinks a code. One blink means a low battery condition (below 4 V). Two blinks mean a parasitic pilot flame. Three blinks mean the system is locked out, for example after a failed ignition; the IFC makes one ignition attempt of about 60 seconds before it locks out. Remove whatever caused the lockout, then reset the IFC. These codes do not apply to the Berkeley-D. If the pilot still won't light, installation and repair should be done by a qualified service person.

  1. Turn the system off with the ON/OFF button on the remote. Wait about 2 seconds and press ON/OFF again. (C-14873, p. 39)
  2. Or, in manual flame control mode, press the down arrow until OFF shows on the remote, wait about 2 seconds and press the up arrow. The ignition sequence starts. (C-14873, p. 39)
  3. Or, with the remote off, disconnect main power to the stove for a few seconds and reconnect it. Wait about 2 seconds and press the reset button on the IFC. (C-14873, p. 39)

Source: Enviro C-14873, p. 37; C-14873, p. 39; C-14873, p. 3

Why won't my Berkeley pilot stay lit?

If the pilot or burners have gone out on their own, open the glass door and wait 5 minutes to air out the stove before you relight it. On the millivolt Berkeley-Nova the troubleshooting table points to the thermocouple circuit (a loose connection at the valve, a pilot flame that doesn't fully surround the thermocouple, or a thermocouple reading under 5 mV) and to air in the gas line. On the Berkeley-IPI it points to the flame sensor connection, the pilot flame size, the pilot ground wire and the vent restrictor setting. On an IPI stove in continuous pilot (CPI) mode the pilot stays lit after you turn the stove off; Enviro recommends CPI in winter when it is below 50°F (10°C) outside. Repairs should be done by a qualified service person.

Source: Enviro C-14872, p. 3; C-14872, p. 37; C-14873, p. 38; C-14873, p. 11; C-14873, p. 12

How do I clean the glass on a Berkeley?

Clean the glass only when the stove is cold. Condensation on a cold start is normal, and the first paint cure can leave a slight film behind the glass. After the first burn, which Enviro says to run on high with the fan off for the first 4 hours, let the stove get cold and clean the glass. Plan to clean it again about two weeks after installation, then no more than two or three times a season. Use a mild glass cleaner and a soft cloth; abrasive cleaners damage the glass and painted surfaces.

  1. Turn the stove off and let it cool completely. Don't touch or remove the glass door unless the stove is completely cold. (C-14872, p. 12)
  2. Lift the cast top straight off and lay it on a towel or blanket so the finish doesn't scratch. (C-14872, p. 12)
  3. Remove the cast door, with its safety screen attached: pull the bottom out, then lift it up to unhook the top. (C-14872, p. 12)
  4. Pull each of the two latches on top of the glass door straight out and up, then lift the door out of the alignment slot at the bottom of the firebox. (C-14872, p. 12)
  5. Check that the gasket on the back of the glass is attached and intact, then clean the glass with a mild glass cleaner and a soft cloth. (C-14872, p. 11)
  6. Refit the glass door, cast door and top in reverse order. Never run the stove with the glass door removed. (C-14872, p. 12)

Source: Enviro C-14872, p. 5; C-14872, p. 11; C-14872, p. 12

The Berkeley glass is cracked. What do I need?

Stop using the stove: don't run it with the glass removed, cracked or broken. The glass is a high temperature ceramic and needs a factory replacement bought from an Enviro dealer; no substitute materials are allowed. Removing and replacing the glass in the door must be done by a licensed or qualified service person. The replacement glass comes with a new gasket and is set with high temperature silicone. The front and side door glass are separate parts. The parts lists give 50-3235 for the front door glass with gasket (16.875 x 21.0625 in), 50-3237 for the side door glass with gasket (15.875 x 11.625 in), and 50-3236 and 50-3238 for the complete front and side doors.

Source: Enviro C-14872, p. 11; C-14872, p. 38; C-14873, p. 40

Can I convert a Berkeley from natural gas to propane?

Yes, with the certified conversion kit, installed by a qualified service agency only. On the millivolt Berkeley-Nova the kit has the burner orifices, an instruction sheet and a conversion label; the installer also moves the pilot's NAT/LP slider and flips the conversion screw in the S.I.T. valve. Its parts list gives 50-3262 (NG to LP) and 50-3261 (LP to NG). The Berkeley-IPI manual's kit list has the burner orifices, an LP pilot orifice and a servo regulator with diaphragm, while its parts list sells the NG to LP conversion as a stepper motor only, 50-3753, so confirm the kit with your dealer. Either way the installer leak-tests the connections, checks the inlet and manifold pressures and fits the conversion label on or close to the rating label.

Source: Enviro C-14872, p. 14; C-14872, p. 15; C-14872, p. 16; C-14872, p. 38; C-14873, p. 18; C-14873, p. 19; C-14873, p. 40

What yearly maintenance does a Berkeley need?

Enviro says the stove should be inspected before first use and at least once a year by a qualified service person, with more frequent cleaning if there is a lot of lint from carpeting or bedding. At least once a year check that all the burner ports are clear and that nothing blocks the pilot; the pilot flame should be blue with little or no yellow on the tips. Inspect the venting every year for blockage and signs of deterioration; Enviro recommends a qualified agency do that. Once a year remove the logs and check them for deterioration or heavy soot (a little on the underside is normal), and while they are out check the ceramic burner for cracks; then reset the logs as the manual shows. Wipe the painted surfaces with a damp cloth, never while hot.

Source: Enviro C-14872, p. 3; C-14872, p. 10; C-14872, p. 11; C-14872, p. 35

Key specs

Gas input, Berkeley-Nova
27,000 to 40,000 BTU/h natural gas; 30,000 to 39,000 BTU/h propane (C-14872, p. 31)
Gas input, Berkeley-IPI and Berkeley-D
Berkeley-IPI 13,000 to 40,000 BTU/h natural gas and 16,000 to 39,000 BTU/h propane; Berkeley-D minimum 27,000 BTU/h natural gas and 30,000 BTU/h propane (C-14873, p. 31)
Manifold pressure
3.6" W.C. natural gas, 10.0" W.C. propane (C-14872, p. 31)
Gas connection
3/8" female NPT on a certified flexible pipe, left side (C-14872, p. 31)
Venting
Direct vent, co-axial 4" intake / 6 5/8" exhaust rigid vent to a vertical or horizontal termination, 36" (91 cm) to 44 ft (13.4 m) long (C-14872, p. 18)
Vent limits
Horizontal run up to 14 ft (4.27 m) with one elbow in the horizontal plane; a total of two 90° or four 45° elbows; the supplied air restrictor is set from the vent chart for vertical runs of 10 ft (3.05 m) or more (C-14872, p. 22)
Clearances to combustibles
12" side wall, 5.0" back wall, 7.43" (18.9 cm) corner, 27.5" ceiling; a hearth pad is required on carpet (C-14872, p. 17)
Certified altitude
0 to 4500 ft (1372 m) (C-14872, p. 5)
Remote (Berkeley-IPI)
Proflame 2 transmitter, three 1.5 V AAA batteries, 315 MHz (C-14873, p. 9)
Controller power (Berkeley-IPI)
120 V / 60 Hz, with four 1.5 V AA batteries as backup (C-14873, p. 9)

Need a part for your Enviro Berkeley?

29 of 53 parts-list items are sold here.

Shop Enviro Berkeley parts
  • Enviro Berkeley-IPI parts
Not sure which part? Find my part

Gas work, venting, electrical and glass replacement must be done by a qualified installer or service agency. These answers summarize Enviro's manuals; the manual for your exact model and serial number is the authority.

Enviro Fireplace Fan Blower with Mounting Bracket - Berkeley/Q1/Q2/Q3/S20/S40 (50-3836)

Sale price $286.67 CAD Regular price $315.99 CAD

Enviro EC-038A EC-039A Fan Controller — Enviro Fireplace Parts

Enviro Fan Controller - Q1/Q2/Ascot/E20/E30/Westport... (EC-039A)

Sale price $119.51 CAD Regular price $131.99 CAD

Enviro Fan Control Knob- Freestanding Gas & Pellet (EC-040) — Enviro Fireplace Parts

Enviro Fan Control Knob- Freestanding Gas & Pellet (EC-040)

Sale price $8.85 CAD Regular price $10.00 CAD

Enviro EC-023 Westport Piezo Igniter — Enviro Fireplace Parts

Enviro Piezo Spark Ignitor - Many Fireplace Models (EC-023)

Sale price $44.25 CAD Regular price $50.00 CAD

Enviro Insert EC-026 Fan Switch — Enviro Fireplace Parts

Enviro Burner / Rocker Switch - Many Models (EC-026)

Sale price $30.00 CAD Regular price $33.99 CAD

See all Enviro Berkeley parts →
Convection fan with mount
50-3836
$286.67 CAD →
5Battery holder, 4 x AA50-3027$41.82 CAD →
6Proflame 2 IFC50-3791$342.06 CAD →
–Proflame 2 IFC wire harness (0.584.924)50-3030Request it
–IFC ON/OFF jumper50-3205Request it
7Proflame 2 transmitter (TMFSLA)50-3265$185.45 CAD →
8PSE IPI pilot assembly (2021)50-4058$120.00 CAD →
–IPI LP pilot orifice (2021)50-4080$22.00 CAD →
9S.I.T. 885 valve with NG stepper motor50-2682$270.00 CAD →
10Heyco strain reliefEC-044$73.29 CAD →
11Domestic power cord (115 V)EC-042$55.38 CAD →
12Log set (9 pieces)option50-3234Request it
13Ceramic burner assembly50-3233$670.77 CAD →
14Front door glass with gasket (16.875 x 21.0625 in)50-3235$286.60 CAD →
15Front door complete50-3236Request it
16Side door glass with gasket (15.875 x 11.625 in)50-3237$188.36 CAD →
17Side door complete50-3238Request it
18Ceramic fluted liner (1 piece)option50-3239$261.42 CAD →
19Replacement safety screen, front50-3243Request it
20Replacement safety screen, side50-3244$201.96 CAD →
21Vent collar cover50-3245Request it
22Termination guard50-3266$202.50 CAD →
23Berkeley-IPI owner's manual50-3260Request it
–Conversion kit, NG to LP (stepper motor only)option50-3753$187.20 CAD →
–Metallic black touch-up paint, 12 oz canPAINT-12-MBRequest it
$306.67 CAD
31Cast skirt, painted50-3250Request it
–Cast skirt, enamelled Antique Chestnut50-3251$114.58 CAD →
32Cast right side, painted50-3252Request it
–Cast right side, enamelled Antique Chestnut50-3253Request it
33Cast left side, painted50-3254Request it
–Cast left side, enamelled Antique Chestnut50-3255Request it
34Cast leg, painted (1 piece)50-3256Request it
–Cast leg, enamelled Antique Chestnut (1 piece)50-3257$103.33 CAD →
, and 45 parts are tagged to fit the Enviro Berkeley