Enviro Parts Only / One brand, every part
Search by Model / Find your exact unit
14-Day Returns / See our returns policy
Expert Advice / From people who care
Enviro Fireplace PartsEvery Enviro part, the right fit.
SupportWe're here to helpTrack OrderCheck status
Find My PartFind the right fit
  • Models
  • Find My Part
  • Manuals
  • Contact
Menu
  • Models
  • Find My Part
  • Manuals
  • Contact
Enviro Fireplace PartsEvery Enviro part, the right fit.
Find My Part Request a Part
Enviro Fireplace Parts

Every Enviro part, the right fit.

Get fitment tips, restock alerts, and Enviro parts news — straight to your inbox.

Shop

  • Shop by Model
  • Shop by Category
  • All Parts

Parts by Appliance

  • Wood Stove Parts
  • Gas Fireplace Parts
  • Pellet Stove Parts

Help & Support

  • Find My Part
  • Request a Part
  • Help Centre
  • Shipping & Delivery
  • Returns & Refunds
  • Warranty

Company

  • About Us
  • Contact Us
  • Blog

© 2026 Enviro Fireplace Parts. All rights reserved.

Enviro Fireplace Parts is operated by Friendly Fires Inc. · (705) 741-1900

PrivacyTermsAccessibility
  • Home
  • Models
  • Parts
  • Support
  • Cart
  1. Home
  2. Manuals
  3. Enviro S40

Manuals & parts · Freestanding direct vent gas stove

Enviro S40 Manuals

Quick answer

The current Enviro S40 manuals are C-14868 R2 (S40, standing pilot lit by hand with a piezo ignitor) and C-16085 R1 (S40I and S40ID, electronic ignition with the Proflame 2 remote), both free PDFs from enviro.com. Stoves from before those revisions are covered by the archived first editions of the same documents. The rating label hangs on a plate on the back of the stove.

Owner's manuals for every Enviro S40 and S40I freestanding gas stove since 2016, the factory parts lists with part numbers, key specs, and answers to common S40 questions, each taken from the official Enviro manual with the page number.

Last updated Nov 25, 2026 · From Enviro docs C-14868 rev R2 and C-16085 rev R1 · Answers drafted from the manuals; staff review pending

Shop Enviro S40 partsGet the manual

Which Enviro S40 do I have?

S40

Standing pilot model. SIT Nova valve with a thermocouple and thermopile, a gas control knob, a piezo ignitor, a burner switch at the top right rear and a HI/LO knob; the convection fan has its own speed knob. Can be run from an optional remote or wall thermostat. Current manual C-14868 R2.

Manuals: C-14868

S40I

Intermittent pilot ignition (IPI) with the Proflame 2 remote (TMFSLA transmitter) and controller: six flame levels, six fan speeds, thermostat and smart thermostat modes, and a four AA battery backup. The pilot lights itself; never light it by hand. Current manual C-16085 R1.

Manuals: C-16085

S40ID

Dexen control-system version of the S40I, added to the C-16085 R1 manual. Remote operation, wiring, troubleshooting and S40ID-specific replacement parts are in the separate Dexen user manual supplied with the stove.

Manuals: C-16085

Find your model and serial number: The rating label and the lighting instructions are on a plate hanging on the back of the stove. (Enviro C-14868, p. 6)

Diagram of an Enviro S40 showing where the rating label with the model and serial number is: The S40 rating label and lighting instructions are on a plate hanging on the back of the stove.
Where to find the Enviro S40 rating label. Our diagram, based on Enviro C-14868 p. 6.
Chart of Enviro S40 versions: S40, S40I, S40ID, with what sets each one apart.

Enviro S40 parts from the manual, sold here

Enviro Berkeley/S40 Firebox Air Restrictor (50-3231) — Enviro Fireplace Parts

Enviro Berkeley/S40 Firebox Air Restrictor (50-3231)

Sale price $46.67 CAD Regular price $51.99 CAD

Enviro Ceramic Fan Sensor (EC-001) — Enviro Fireplace Parts

Enviro Ceramic Fan Sensor (EC-001)

Sale price $77.79 CAD Regular price $85.99 CAD

Enviro 50-2493 Replacement Blower — Enviro Fireplace Parts

Enviro Replacement Blower - Many Models (50-2493)

Sale price $243.33 CAD Regular price $267.99 CAD

Enviro Blower with Mounting Bracket - Berkeley/Q1/Q2/Q3/S20/S40 (50-3836) — Enviro Fireplace Parts
Enviro S40 versions at a glance. Our chart, from the Enviro manuals listed below.

Enviro S40 owner's and installation manuals

Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.

  • S40I Owner's Manual R1

    C-16085 rev R1 · Dec 1, 2021 – Present · 48 pages · Current

    PDF
  • S40 Owner's Manual R2

    C-14868 rev R2 · Jun 1, 2020 – Current · 44 pages · Current

    PDF
Older Enviro S40 manuals (2)
  • S40I Owner's Manual

    C-16085 · Nov 1, 2020 – Dec 01, 2021

    PDF
  • S40 Owner's Manual

    C-14868 · Jun 27, 2016 – May 31, 2020

    PDF

Can't open a link? Enviro lists every version on its manuals pages: Enviro S40 manuals.

Enviro S40 parts list, with part numbers

From the parts lists in the Enviro S40 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.

S40 (standing pilot, Nova valve) (Enviro C-14868, p. 38)

RefPartPart #Our store
1Door latch mechanism with spring (set of 2)50-1285Request it
2Firebox air restrictor50-3231$46.67 CAD →
3Pilot shield50-3232Request it
4120 ceramic fan temperature sensorEC-001$77.79 CAD →
5Convection fan only50-2493$243.33 CAD →
–Convection fan with mount50-3836$286.67 CAD →
6Fan controller (69.5 V), 115 V, with knobEC-039A$119.51 CAD →
7Fan controller knob with decalEC-040$8.85 CAD →
8S.I.T. piezo ignitorEC-023$44.25 CAD →
9Burner switchEC-026$30.00 CAD →
10Control panel and decal50-2989Request it
11PSE pilot assembly, standing pilot50-2513Request it
12S.I.T. Nova valve, convertible50-1421Request it
13Heyco strain reliefEC-044$73.29 CAD →
14Domestic power cord (115 V)EC-042$55.38 CAD →
15Log set (9 pieces)50-3234Request it
16Ceramic burner assembly50-3233$670.77 CAD →
17Front door glass with gasket (16.875 x 21.0625 in)50-3235$286.60 CAD →
18Front door complete50-3236Request it
19Ceramic fluted liner (1 piece)50-3239$261.42 CAD →
20S40 cabinet front50-3240Request it
21S40 plate top50-3241Request it
22S40 leg set (4 pieces)50-3242Request it
23Replacement safety screen50-3243Request it
24B-vent drafthood adaptoroption50-3667Request it
25Vent collar cover50-3245Request it
26Termination guardoption50-3266$202.50 CAD →
27S40 owner's manual50-3258Request it
–Conversion kit, LP to NG (Nova)option50-3261$99.28 CAD →
–Conversion kit, NG to LP (Nova)option50-3262$78.33 CAD →
–Metallic black touch-up paint, 12 oz canPAINT-12-MBRequest it

S40I / S40ID (Proflame 2 IPI) (Enviro C-16085, p. 43)

RefPartPart #Our store
1Door latch mechanism with spring (set of 2)50-1285Request it
2Firebox air restrictor50-3231$46.67 CAD →
3Pilot shield50-3232Request it
4Battery holder, 4 x AA50-3027$41.82 CAD →

Enviro S40 questions, answered from the manual

Where is the serial number on an Enviro S40?

On the rating label. The rating label and the lighting instructions are on a plate hanging on the back of the stove; the S40I and S40ID manual gives the same place. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual, and Enviro asks for the serial number for warranty claims.

Source: Enviro C-14868, p. 6; C-16085, p. 6; C-14868, p. 44; C-14868, p. 43

Which S40 manual do I need?

Check the model on the rating label. The S40 has a standing pilot that you light by hand with a piezo ignitor, an SIT Nova valve and a burner switch: use C-14868 (current revision R2, from June 2020; the 2016 to 2020 first edition is archived). The S40I lights itself and runs on the Proflame 2 remote: use C-16085 (current revision R1, from December 2021). The S40ID is covered by the same C-16085 R1 manual, but its remote operation, wiring, troubleshooting and replacement parts are in the separate Dexen user manual supplied with the stove. The first C-16085 edition, from November 2020 to December 2021, covers the S40I only.

Source: Enviro C-14868, p. 7; C-14868, p. 38; C-16085, p. 7; C-16085, p. 9; C-16085, p. 43

How do I light the pilot on an Enviro S40?

On the standing-pilot S40 you light the pilot by hand with the piezo ignitor, following the lighting label. The valve has a lockout, so the pilot can't be relit until the thermocouple has cooled. If the knob does not pop up when released, stop and call your service technician or gas supplier right away. If the pilot won't stay lit after several tries, turn the knob clockwise to OFF and call them.

  1. Set the thermostat to its lowest setting, turn off all electric power to the stove and open the front control panel. (C-14868, p. 7)
  2. Turn the gas control knob clockwise to OFF. Open the door, wait five minutes to clear out any gas, close it, then smell for gas, including near the floor. If you smell gas, stop and follow the safety instructions on the label. (C-14868, p. 7)
  3. Find the pilot near the center rear of the firebox. Turn the gas control knob counter-clockwise to PILOT and push it in fully. (C-14868, p. 7)
  4. While holding the knob in, press the piezo ignitor several times until the pilot lights. Keep holding the knob for 30 seconds, release it, and check that the pilot flame fully engulfs the thermocouple. (C-14868, p. 8)
  5. Turn the knob counter-clockwise to ON, flip the burner switch at the top right rear of the stove to ON and set the HI/LO knob. Check that all burner holes are lit. (C-14868, p. 9)
  6. Close the front control panel, turn the electric power back on and set the thermostat. (C-14868, p. 7)

Source: Enviro C-14868, p. 7; C-14868, p. 8; C-14868, p. 9

How do I pair the Proflame 2 remote to my S40I?

Initialize the system the first time you use it and after you replace batteries, using the red reset button on the front right corner of the integrated fireplace controller (IFC). Enviro says to turn off the main gas supply to the stove before removing or reinserting the IFC batteries. For an S40ID, follow the Dexen user manual supplied with the stove instead.

  1. Install four AA batteries in the IFC battery holder, matching the polarity marked on the holder. (C-16085, p. 11)
  2. Press the reset button on the IFC marked SW1. The IFC beeps three times when it is ready to pair. (C-16085, p. 11)
  3. With the three AAA batteries in the base of the remote, press its ON button. (C-16085, p. 11)
  4. The IFC beeps four times to confirm it has accepted the remote. The system is now initialized. (C-16085, p. 11)
  5. Press ON/OFF to start the stove. The IFC beeps once, lights the pilot and then the main burner, which takes about 10 seconds. (C-16085, p. 11)

Source: Enviro C-16085, p. 9; C-16085, p. 10; C-16085, p. 11

My S40I won't light or the controller light is blinking. What should I do?

The Proflame 2 controller (IFC) makes one ignition attempt of about 60 seconds; if it senses no flame it locks out. Its LED blinks a code: once for a low battery (under 4 V), twice for a parasitic pilot flame, three times for a failed ignition or system lockout. Air in the gas line can take a while to purge out of the pilot before gas reaches it and lights. If the remote gets no reaction, replace its batteries or re-initialize it to the IFC. These codes don't apply to the S40ID, which is covered by the Dexen user manual.

  1. Press ON/OFF on the remote to turn the system off, wait about 2 seconds and press ON/OFF again. (C-16085, p. 42)
  2. Or, in manual flame mode, press the down arrow until the screen shows OFF, wait about 2 seconds and press the up arrow. The ignition sequence starts. (C-16085, p. 42)
  3. If it is still locked out, turn the remote off, disconnect the stove's main power for a few seconds and reconnect it. Wait about 2 seconds and press the reset button on the IFC. (C-16085, p. 42)

Source: Enviro C-16085, p. 40; C-16085, p. 41; C-16085, p. 42

Does the S40I work in a power outage?

The S40I controller runs mainly on 120 VAC, but it can also run for shorter periods on a backup of four AA batteries. How long they last in a prolonged power outage depends on the battery quality, how often the stove is lit and how often the thermostat set point is changed. When the controller batteries are low, it gives no beep when it receives an ON/OFF command from the remote; after you replace them, initialize the system again. The S40 manual does not cover power outages for the standing-pilot S40, so check with your dealer.

Source: Enviro C-16085, p. 10; C-16085, p. 14

Why does my S40I pilot stay lit?

It is set to continuous pilot (CPI). With the stove off, press MODE until the CPI icon shows; the up arrow selects continuous pilot and the down arrow returns to intermittent pilot (IPI), and the controller beeps once to confirm. Enviro recommends continuous pilot in winter when it is below 50°F (10°C) outside: it keeps the chimney warm for updraft at ignition and keeps the firebox warm, which cuts condensation on the glass. The pilot is on-demand and shuts itself off after 7 consecutive days left dormant.

Source: Enviro C-16085, p. 11

How do I clean the glass on an Enviro S40?

Condensation on a cold start is normal and clears as the stove warms up, but it lets dust and lint cling to the glass, and additives in the gas can leave a haze. The first paint cure can also leave a film, so clean the glass about two weeks after installation, then usually no more than two or three times a season, and never when it is hot. Use a mild glass cleaner and a soft cloth; abrasive cleaners damage the glass and painted surfaces.

  1. Turn the stove off and let it cool completely. Don't touch or remove the glass door unless the stove is completely cold. (C-14868, p. 12)
  2. Lift the top plate up and off, then lift the cabinet front, with the safety screen attached, up and out. Lay both on a towel or blanket so the finish doesn't scratch. (C-14868, p. 12)
  3. Pull each of the two latches on top of the glass door straight out and up by hand, then lift the door up out of the alignment slot at the bottom of the firebox. (C-14868, p. 12)
  4. Check that the gasket on the back of the glass is attached and intact. (C-14868, p. 11)
  5. Clean the glass with a mild glass cleaner and a soft cloth. (C-14868, p. 11)
  6. Refit the glass door, the cabinet front and the top plate in reverse order. Never run the stove with the glass door removed. (C-14868, p. 12)

Source: Enviro C-14868, p. 11; C-14868, p. 12; C-14868, p. 37

The S40 glass is cracked. What do I need?

Stop using the stove: don't run it with the glass cracked, broken or removed. The glass is high temperature ceramic and must be a factory replacement bought from an Enviro dealer, and taking it out of the door and fitting the new one must be done by a licensed or qualified service person. The replacement glass comes with a new gasket installed. Both S40 parts lists give 50-3235 for the front door glass with gasket (16.875 x 21.0625 in) and 50-3236 for the complete front door.

Source: Enviro C-14868, p. 11; C-14868, p. 38; C-16085, p. 43

Can I convert an S40 from natural gas to propane?

Yes, with a certified conversion kit, installed by a qualified service agency only. For the S40 the parts list gives 50-3262 (NG to LP) and 50-3261 (LP to NG); the kit holds new burner orifices, an instruction sheet and a conversion label. The installer swaps the burner orifices, slides the pilot injector to the new gas and flips the screw in the Nova valve. The S40I kit holds the burner orifices, an LP pilot orifice and a servo regulator with diaphragm (acquired separately); the S40I parts list gives 50-3753 for the NG to LP stepper motor. After a leak test and a pressure check, the conversion label goes on or near the rating label.

Source: Enviro C-14868, p. 14; C-14868, p. 15; C-14868, p. 16; C-14868, p. 38; C-16085, p. 18; C-16085, p. 43

Why does my new S40 smoke and smell?

The first burns cure the paint, logs, gasket material and other products used in manufacturing. Run the stove on high with the fan off: the notice at the front of the manual says for the first 4 hours, and the burner lighting section says the first two to four hours. Open a window or door, because the smoke can irritate some people. Then turn the stove off, including the pilot, let it get completely cold, and clean the glass with a gas fireplace glass cleaner.

Source: Enviro C-14868, p. 5; C-14868, p. 9

Key specs

Gas input, natural gas
27,000 to 40,000 BTU/h (C-14868, p. 31)
Gas input, propane
30,000 to 39,000 BTU/h (C-14868, p. 31)
Manifold pressure
3.6" W.C. natural gas, 10.0" W.C. propane (C-14868, p. 31)
Supply pressure
4.5" to 7.0" W.C. natural gas; 10.4" to 11.0" W.C. propane (C-14868, p. 31)
Gas connection
3/8" female NPT on a certified flexible pipe, left side (C-14868, p. 31)
Venting
Direct vent, co-axial 4" intake / 6 5/8" exhaust; total vent length 36" (91 cm) to 44 ft (13.4 m); vertical or horizontal termination (C-14868, p. 18)
Clearances to combustibles
Side wall 11.375", back wall 5.0", corner 7.43", ceiling 28.625"; 0" to a hardwood or linoleum floor (hearth pad on carpet) (C-14868, p. 17)
Certified altitude
0 to 4,500 ft (1,372 m) (C-14868, p. 5)
Remote (S40I)
Proflame 2 TMFSLA transmitter, three AAA batteries, 315 MHz (C-16085, p. 9)
Controller power (S40I)
120 V / 60 Hz, with four AA batteries as backup (C-16085, p. 9)

Need a part for your Enviro S40?

23 of 42 parts-list items are sold here.

Shop Enviro S40 partsNot sure which part? Find my part

Gas work, venting, electrical and glass replacement must be done by a qualified installer or service agency. These answers summarize Enviro's manuals; the manual for your exact model and serial number is the authority.

Enviro Fireplace Fan Blower with Mounting Bracket - Berkeley/Q1/Q2/Q3/S20/S40 (50-3836)

Sale price $286.67 CAD Regular price $315.99 CAD

Enviro EC-038A EC-039A Fan Controller — Enviro Fireplace Parts

Enviro Fan Controller - Q1/Q2/Ascot/E20/E30/Westport... (EC-039A)

Sale price $119.51 CAD Regular price $131.99 CAD

Enviro Fan Control Knob- Freestanding Gas & Pellet (EC-040) — Enviro Fireplace Parts

Enviro Fan Control Knob- Freestanding Gas & Pellet (EC-040)

Sale price $8.85 CAD Regular price $10.00 CAD

Enviro EC-023 Westport Piezo Igniter — Enviro Fireplace Parts

Enviro Piezo Spark Ignitor - Many Fireplace Models (EC-023)

Sale price $44.25 CAD Regular price $50.00 CAD

Enviro Insert EC-026 Fan Switch — Enviro Fireplace Parts

Enviro Burner / Rocker Switch - Many Models (EC-026)

Sale price $30.00 CAD Regular price $33.99 CAD

See all Enviro S40 parts →
5Convection fan only50-2493$243.33 CAD →
–Convection fan with mount50-3836$286.67 CAD →
6Proflame 2 integrated fireplace controller (IFC)50-3791$342.06 CAD →
–Proflame 2 IFC wire harness (0.584.924)50-3030Request it
–IFC on/off jumper50-3205Request it
7Proflame 2 transmitter (TMFSLA)50-3265$185.45 CAD →
8PSE IPI pilot assembly (2021)50-4058$120.00 CAD →
–IPI LP pilot orifice (2021)50-4080$22.00 CAD →
9S.I.T. 885 valve with NG stepper motor50-2682$270.00 CAD →
10Heyco strain reliefEC-044$73.29 CAD →
11Domestic power cord (115 V)EC-042$55.38 CAD →
12Log set (9 pieces)50-3234Request it
13Ceramic burner assembly50-3233$670.77 CAD →
14Front door glass with gasket (16.875 x 21.0625 in)50-3235$286.60 CAD →
15Front door complete50-3236Request it
16Ceramic fluted liner (1 piece)50-3239$261.42 CAD →
17S40 cabinet front50-3240Request it
18S40 leg set (4 pieces)50-3242Request it
19S40 plate top50-3241Request it
–Berkeley / S40 relief gasket50-3969Request it
20Replacement safety screen50-3243Request it
21Vent collar cover50-3245Request it
22S40I / S40ID owner's manual50-4052Request it
–Metallic black touch-up paint, 12 oz canPAINT-12-MBRequest it
23B-vent drafthood adaptoroption50-3667Request it
24Termination guardoption50-3266$202.50 CAD →
–NG to LP stepper motor onlyoption50-3753$187.20 CAD →
, and 38 parts are tagged to fit the Enviro S40