Quick answer
The Vista Flame VF170 is a discontinued freestanding pellet stove, and Enviro lists all of its manuals as archived. The last ones are the VF170B owner's manual C-12171 and technical manual C-12172 (2012), free PDFs from enviro.com; the technical manual has the installation steps and the parts list. VF170 parts are still sold here, and the rating label is on the inside of the hopper lid.
Every VF170 and VF170B owner's and technical manual Enviro still publishes, the factory parts list with part numbers (with the differences of the first 2008 VF170), key specs, and answers to common VF170 questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the Vista Flame VF170, but we still sell its parts.
Last updated · From Enviro docs C-12172, C-12171, C-11633 and C-11573 · Answers drafted from the manuals; staff review pending
VF170B
Freestanding pellet stove with a control board that has Feed Rate Trim and Combustion Blower Trim buttons, a 4" exhaust vent and a hopper of up to 130 lb. Enviro publishes an owner's manual for the homeowner and a technical manual for the installer.
Manuals: C-12171, C-12172, C-11911, C-11912
VF170 (2008)
The first VF170, covered by Enviro's 2008 technical manuals (its owner's manual, C-11572, is listed by Enviro but the link does not return the PDF). Its parts list has a different control panel and circuit board, and the May 2008 manual lists a 3" exhaust starter tube.
Manuals: C-11633, C-11573
Find your model and serial number: The rating label is on the inside of the hopper lid. (Enviro C-12172, p. 5)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro Vista Flame VF170 is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro Vista Flame VF170 parts.
VF170B Domestic Technical Manual
C-12172 · From Mar 6, 2012
VF170B Domestic Owner's Manual
C-12171 · From Feb 17, 2012
VF170B Domestic Owner's Manual
C-11911 · From May 12, 2009
VF170B Domestic Technical Manual
C-11912 · From May 12, 2009
VF170 Domestic Technical Manual
C-11633 · From Jul 21, 2008
VF170 Domestic Technical Manual
C-11573 · May 14, 2008 – Jul 21, 2008
Can't open a link? Enviro lists every version on its manuals pages: Enviro VF170 manuals, Enviro legacy manuals.
From the parts lists in the Enviro Vista Flame VF170 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Ceramic fan temperature sensor, 120 °F (49 °C) | EC-001 | $77.79 CAD → |
| 2 | IEC power cord (115 V) | EC-043 | $76.90 CAD → |
| – | Window channel tape, 6 ft (1.8 m) | EC-058 | Request it |
| 3 | High limit temperature sensor, 200 °F (93 °C), manual reset | EF-016 | $79.80 CAD → |
| – | Silicone hose | EF-018 | $38.00 CAD → |
| 4 | Slider damper rod with knob | EF-050 | $71.62 CAD → |
| 5 | Glass, large (9" x 13", 229 x 330 mm) | EF-061 | $172.20 CAD → |
| 6 | 1" knob | EF-068 | $68.10 CAD → |
| 7 | Shoulder bolt, roller and nut (set of 2) | EF-124 | $69.64 CAD → |
| – | Pellet stove cleaning brush | EF-156 | $36.83 CAD → |
| – | Ash pan gasket, 10 ft (3.0 m) | EF-208 | $52.00 CAD → |
| – | Door gasket, ¾" firm round x 80" (7 ft, 2.1 m) | EF4i-056 | $63.84 CAD → |
| 8 | IEC power cord inlet socket | 50-713 | Request it |
| 9 | Circuit board 5 A fuse, 115 V (set of 2) | 50-833 | $40.91 CAD → |
| 10 | ⅝" ID auger collar with screw | 50-968 | $65.11 CAD → |
| 11 | Slider damper set collar kit | 50-1068 | $85.11 CAD → |
| 12 | Auger with paddles | 50-1161 | $192.73 CAD → |
| – | Burn pot scraper tool | 50-1254 | Request it |
| 13 | Leveling legs, 1½" (set of 4) | 50-1342 | Request it |
| 14 | Vacuum switch, low pressure | 50-1390 | $130.00 CAD → |
| – | Auger tube cover | 50-1410 | Request it |
| 15 | 4" exhaust starter tube gasket | 50-1913 | Request it |
| – | Control panel decal | 50-1482 | $80.38 CAD → |
| – | 600 W backup systemoption | 50-1547 | Request it |
| 16 | Auger stops (clear rubber) | 50-1559 | Request it |
| 17 | Hopper lid hinge, left | 50-1633 | Request it |
| 18 | Hopper lid hinge, right | 50-1634 | Request it |
| 19 | Hopper lid | 50-1635 | Request it |
| 20 | Heat exchanger rod | 50-1638 | $77.20 CAD → |
| 21 | Back grill, top | 50-1639 | Request it |
| 22 | Back grill, bottom | 50-1640 | Request it |
| 23 | Slider damper plate | 50-1644 | $87.49 CAD → |
| 24 | Firebox baffle | 50-1645 | $94.23 CAD → |
| 25 | Ash pan | 50-1646 | $209.23 CAD → |
| 26 | Glass retainer | 50-1649 | Request it |
| 27 | Inner door (no glass) | 50-1651 | Request it |
| – | Circuit board decal | 50-1930 | $59.11 CAD → |
| 28 | Control panel with decal | 50-1931 | $98.33 CAD → |
| 29 | Circuit board with thermostat switch, 115 V | 50-1929 | Request it |
| 30 | Ignitor assembly | 50-1656 | $140.00 CAD → |
| 31 | Auger motor, 3 rpm, 120 V | 50-1657 | Request it |
| 32 | Auger plate and bushing assembly | 50-1658 | $85.56 CAD → |
| 33 | Convection blower | 50-1659 | $250.00 CAD → |
| 34 | Combustion blower assembly | 50-1660 | Request it |
| 35 | Burn pot | 50-1661 | Request it |
| 36 | Burn pot liner | 50-1662 | $140.00 CAD → |
| 37 | 4" exhaust starter tube with flange, 5" long | 50-1914 | Request it |
| 38 | Combustion blower motor mounting gasket | 50-1664 | $59.53 CAD → |
| – | Circuit board wiring harness | 50-1666 | $126.17 CAD → |
| 39 | Auger brass bushings (set of 2) | 50-1806 | $80.00 CAD → |
| 40 | Door | 50-1851 | Request it |
| 41 | Trivet | 50-1852 | Request it |
| 42 | Top front with mount | 50-1853 | Request it |
| 43 | Cabinet side, left | 50-1854 | Request it |
| 44 | Cabinet side, right | 50-1855 | Request it |
| 45 | Louver assembly | 50-1856 | Request it |
| 46 | Front trim panel | 50-1857 | Request it |
| 47 | Ash pan door | 50-1858 | Request it |
| 48 | Ash shelf | 50-1859 | Request it |
| 49 | Door handle, upper | 50-1860 | Request it |
| 50 | Door handle, lower | 50-1861 | Request it |
| 51 | Hearth shield | 50-1862 | Request it |
| – | VF170 domestic owner's manual | 50-1863 | Request it |
| – | VF170 domestic technical manual | 50-1864 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 28 | Control panel with decal | 50-1654 | Request it |
| 29 | Circuit board | 50-1655 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 15 | Exhaust starter tube gasket | 50-1448 | $60.00 CAD → |
| 37 | Exhaust starter tube with flange, 3" x 5" | 50-1663 | Request it |
On the rating label inside the hopper: the technical manual places it on the inside of the hopper lid, the owner's manual on the inside of the hopper. The installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual; keep it for warranty and future reference.
Source: Enviro C-12172, p. 5; C-12171, p. 3; C-12171, p. 14
All VF170 manuals are archived, and each version has two: an owner's manual for the homeowner and a technical manual for the installer or technician. For a VF170B, use the 2012 pair, owner's manual C-12171 and technical manual C-12172, or the 2009 pair, C-11911 and C-11912. For the first VF170, Enviro publishes the 2008 technical manuals C-11633 and C-11573; its owner's manual, C-11572, is listed but the link returns a web page instead of the PDF.
Source: Enviro C-12171, p. 3; C-12172, p. 3
Check the burn pot liner and the hopper, then press ON/OFF; start-up is automatic and the system light turns solid after about 10 to 15 minutes. To shut down in Manual or High/Low mode, press ON/OFF: the pellet feed stops and the blowers run until the stove has cooled. In Auto/Off mode, turn the thermostat down or off; the stove runs on low for three minutes before it turns off. Don't unplug the stove while the combustion fan is running, as smoke may escape.
Source: Enviro C-12171, p. 7; C-12171, p. 8
Only ¼" (6 mm) diameter wood pellets that are dry and free of dirt or impurities such as high salt content. The stove is approved for wood pellet fuel with up to 3% ash, and Enviro recommends pellets that meet or exceed the Pellet Fuel Industries (PFI) standards. Burning cordwood is prohibited, and so are garbage and flammable liquids. When filling the hopper, check it for foreign objects and don't overfill it. Store pellets at least 36" (1 m) from the stove.
Source: Enviro C-12171, p. 3; C-12171, p. 4
Check the burn pot liner daily and empty the burn pot and liner weekly. Clinkers (hard lumps of silica or other impurities) block the liner's air holes. A fire that keeps overflowing the pot, or a build-up of clinkers, points to poor pellets or a stove that needs cleaning. The burn pot liner is part 50-1662 and the burn pot scraper tool is 50-1254.
Source: Enviro C-12171, p. 10; C-12171, p. 3; C-12172, p. 23; C-12172, p. 24
Daily: check the burn pot liner. Weekly: empty the burn pot and liner, clean the heat exchanger tubes (with the stove cold, lift the trivet and move the two scraper handles all the way up and down a few times), clean the door glass, check the ash pan and door gaskets, and empty the ash box with the stove off. Twice a year or every 2 tons of fuel: the exhaust passages, the fresh air intake and the exhaust vent; Enviro recommends your dealer for cleaning the vent. Once a year: unplug the stove and vacuum the dust from both blowers (their bearings are sealed, so don't oil them). At the end of the season, clean the stove and unplug it.
Source: Enviro C-12171, p. 10; C-12171, p. 11; C-12171, p. 12
A flashing #3 light on the heat output bar means the exhaust temperature switch has opened: no fire is detected or the fire has gone out, for example because the hopper is empty. Strong negative pressure in the room can also cause it; if opening a window helps, the manual calls for a fresh air intake to the stove or room. A flashing #2 light means the vacuum switch has turned the auger off because the venting may be blocked. A flashing #4 light means the 200 °F (93 °C) high limit switch on the hopper has tripped; your dealer has to reset it and find out why the stove overheated. Press ON/OFF to reset the board after a trouble code. Enviro says troubleshooting should be done by qualified technicians or installers.
Source: Enviro C-12172, p. 20; C-12171, p. 7; C-12172, p. 19
Look at what is left in the burn pot liner. Fresh unburned pellets or cigarette-like ash mean the fire is going out before the stove shuts off: check the slider damper position and turn the heat level up slightly (poor pellets need higher settings). Partly burned pellets mean the stove shut down from lack of air, low exhaust temperature or a power failure: adjust the slider damper and check whether the stove needs a more complete cleaning. If the pellets won't light at all, make sure the liner sits tight and square against the ignitor tube; the ignitor should glow bright orange. The slider damper is set by a trained technician with a magnehelic gauge.
Source: Enviro C-12172, p. 21; C-12172, p. 18
Clean it weekly, and only when the stove is cold. The glass is ceramic. If it breaks, don't run the stove; Enviro recommends having your dealer replace it, and the replacement must be the Enviro glass (9" x 13", part EF-061).
Source: Enviro C-12171, p. 11; C-12171, p. 5; C-12171, p. 12
Yes. A switch on the control board selects Manual, High/Low or Auto/Off. In High/Low the stove drops to the low setting when the thermostat is satisfied and returns to your heat level when it calls again. In Auto/Off the stove lights itself when the thermostat calls; when it is satisfied the stove runs on low for 30 minutes and then shuts down unless the thermostat calls again, and relights on the next call. The technical manual specifies a 12 or 24 V thermostat wired with 2 x 18 gauge wire. If the room gets too hot, the high limit switch may turn the stove off and must be reset by hand; it is on the air jacket behind the right cabinet side.
Source: Enviro C-12171, p. 7; C-12171, p. 8; C-12172, p. 8