Enviro Parts Only / One brand, every part
Search by Model / Find your exact unit
14-Day Returns / See our returns policy
Expert Advice / From people who care
Enviro Fireplace PartsEvery Enviro part, the right fit.
SupportWe're here to helpTrack OrderCheck status
Find My PartFind the right fit
  • Models
  • Find My Part
  • Manuals
  • Contact
Menu
  • Models
  • Find My Part
  • Manuals
  • Contact
Enviro Fireplace PartsEvery Enviro part, the right fit.
Find My Part Request a Part
Enviro Fireplace Parts

Every Enviro part, the right fit.

Get fitment tips, restock alerts, and Enviro parts news — straight to your inbox.

Shop

  • Shop by Model
  • Shop by Category
  • All Parts

Parts by Appliance

  • Wood Stove Parts
  • Gas Fireplace Parts
  • Pellet Stove Parts

Help & Support

  • Find My Part
  • Request a Part
  • Help Centre
  • Shipping & Delivery
  • Returns & Refunds
  • Warranty

Company

  • About Us
  • Contact Us
  • Blog

© 2026 Enviro Fireplace Parts. All rights reserved.

Enviro Fireplace Parts is operated by Friendly Fires Inc. · (705) 741-1900

PrivacyTermsAccessibility
  • Home
  • Models
  • Parts
  • Support
  • Cart
  1. Home
  2. Manuals
  3. Enviro E25

Manuals & parts · Direct vent gas fireplace insert

Enviro E25 Manuals

Quick answer

The Enviro E25 manual is C-15958 R1, a free PDF from enviro.com that covers all three versions: the E25 (SIT Nova valve, pilot lit by hand with a piezo ignitor), the E25I (electronic ignition with the Proflame 2 remote) and the E25ID (Dexen remote; the manual sends E25ID owners to a separate Dexen user manual, and Enviro's Dexen system user manual C-16359 does not name the E25 or E25ID). It is the only E25 manual Enviro lists, current since August 2020. The rating label is in the bottom of the unit.

The Enviro E25 owner's manual, the factory parts list with part numbers, key specs, and answers to common E25, E25I and E25ID questions, each taken from the official Enviro manual with the page number.

Last updated Nov 20, 2026 · From Enviro docs C-15958 rev R1 and C-16359 rev R3 · Answers drafted from the manuals; staff review pending

Shop Enviro E25 partsGet the manual

Which Enviro E25 do I have?

E25

Standing pilot model with a SIT Nova valve. The pilot is lit by hand with a piezo ignitor, and the control panel has a gas control knob, a burner switch and a HI/LO knob. The convection fan is optional.

Manuals: C-15958

E25I

Intermittent pilot ignition (IPI) with the Proflame 2 remote and controller (IFC). The IFC and battery pack sit on a sliding tray in the cabinet.

Manuals: C-15958

E25ID

Dexen control-system version, covered by the same owner's manual. Remote operation, valve details and troubleshooting are in the separate Dexen user manual.

Manuals: C-15958, C-16359

Find your model and serial number: The rating label is in the bottom of the unit. (Enviro C-15958, p. 6)

Diagram of an Enviro E25 showing where the rating label with the model and serial number is: The E25 rating label is in the bottom of the unit.
Where to find the Enviro E25 rating label. Our diagram, based on Enviro C-15958 p. 6.
Chart of Enviro E25 versions: E25, E25I, E25ID, with what sets each one apart.
Enviro E25 versions at a glance. Our chart, from the Enviro manuals listed below.

Enviro E25 parts from the manual, sold here

Enviro E25 Log Grate (50-3989) — Enviro Fireplace Parts

Enviro E25 Log Grate (50-3989)

Sale price $22.00 CAD Regular price $24.99 CAD

Enviro Door Tool — Enviro Fireplace Parts

Enviro Door & Glass Release Tool (50-2510)

Sale price $60.00 CAD Regular price $66.99 CAD

Pacific Energy Remote Control Replacement (80000191) — Enviro Fireplace Parts

Enviro Remote Control Replacement (50-3265)

Sale price $185.45 CAD Regular price $204.99 CAD

EF-045 Enviro Blower Speed Control — Enviro Fireplace Parts

Enviro E25 owner's and installation manuals

Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.

  • E25 / E25I / E25ID Owner's Manual R1

    C-15958 rev R1 · Aug 1, 2020 – Current · 46 pages · Current

    PDF
  • Dexen System User Manual R3 (general Dexen manual, does not name the E25ID)

    C-16359 rev R3 · Current · 12 pages · Current

    PDF

Can't open a link? Enviro lists every version on its manuals pages: Enviro E25 manuals.

Enviro E25 parts list, with part numbers

From the parts lists in the Enviro E25 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.

E25 / E25I (Enviro C-15958, p. 44)

RefPartPart #Our store
1E25 log grate50-3989$22.00 CAD →
2Door release tool50-2510$60.00 CAD →
3Flue adapter tool50-3505Request it
4E25 exhaust restrictors50-3990Request it
5Proflame 2 transmitter (E25I)50-3265$185.45 CAD →
6Fan controllerEF-045$40.00 CAD →
7FPI burner switchEC-026$30.00 CAD →
8Battery holder, 4 x AA50-3027$41.82 CAD →
9E25 power cord (115 V)EC-042$55.38 CAD →
10PSE pilot assembly (2021)50-4083$130.00 CAD →
11PSE IPI pilot assembly (2021)50-4058$120.00 CAD →
12S.I.T. Nova valve, convertible (E25)50-3660$244.77 CAD →
13885 Proflame IPI valve, NG (E25I)50-2682$270.00 CAD →
14120 ceramic fan temperature sensorEC-001$77.79 CAD →
15E25 fan only50-3901Request it
16Proflame 2 IFC (E25I)50-3791$342.06 CAD →
17E25 surround assembly50-3845$279.34 CAD →
18E25 safety screen only50-3956$133.52 CAD →
19E25 burner assembly50-3983Request it
20E25 complete door assembly50-3984Request it
21E25 glass and gasket only50-2506$353.33 CAD →
22E25 flue adaptor50-3987Request it
23S.I.T. piezo ignitorEC-023$44.25 CAD →
–E25 brick lineroption50-3844$236.73 CAD →
–E25 valve tray gasket50-3985Request it
–E25 flue adaptor gasket50-3986Request it
–E25 log set50-3988$121.05 CAD →
–Proflame 2 IFC wire harness (0.584.924)50-3030Request it
–E25 conversion kit, NG to LPoption50-3981Request it
–E25 conversion kit, LP to NGoption50-3982$90.00 CAD →
–Ceramic wool embers only50-893Request it
–Metallic black touch-up paint, 12 oz canPAINT-12-MBRequest it

Dexen controls (Dexen system user manual C-16359, not E25 specific) (Enviro C-16359, p. 11)

RefPartPart #Our store
1MH3V gas valve with harness50-4152$203.64 CAD →
2RC300 remote50-4153$132.00 CAD →
38K1N ignition module50-4154Request it
4AUX300 module50-4155$112.00 CAD →

Enviro E25 questions, answered from the manual

Where is the serial number on an Enviro E25?

On the rating label, which is in the bottom of the unit. Enviro asks for the unit serial number for warranty parts and claims, and the installer should record it on the installation data sheet at the back of the manual.

Source: Enviro C-15958, p. 6; C-15958, p. 45; C-15958, p. 46

Which E25 manual do I need?

One owner's manual, C-15958, covers every E25 version. The installer records the model on the installation data sheet at the back of the manual. The E25 has a SIT Nova valve: you light the pilot by hand with a piezo ignitor and run the fire with a burner switch and a HI/LO knob. The E25I has electronic ignition and is run by the Proflame 2 remote. The E25ID uses a Dexen remote; for remote operation, wiring, valve details and troubleshooting the manual refers you to the separate Dexen user manual. Enviro's Dexen system user manual, C-16359, covers Dexen remotes in general and does not name the E25ID.

Source: Enviro C-15958, p. 1; C-15958, p. 8; C-15958, p. 9; C-15958, p. 10; C-15958, p. 33; C-15958, p. 34; C-15958, p. 40; C-15958, p. 46; C-16359, p. 1

How do I light the pilot on an E25?

The E25 (Nova valve) has a pilot you light by hand at the gas valve, using the piezo ignitor. Follow the lighting label, which is printed in the manual. It is an on-demand pilot that shuts off after 7 consecutive days without the main burner running, so you may need to relight it after a long break. If the knob will not push in or turn by hand, don't force it or try to repair it; call a qualified service technician. If the pilot will not stay lit after several tries, turn the knob to OFF and call your service technician or gas supplier. The E25I and E25ID light their own pilot; never light those by hand.

  1. Set the thermostat to the lowest setting and turn off all electric power to the fireplace. (C-15958, p. 8)
  2. Open the front control panel and turn the gas control knob clockwise to OFF. (C-15958, p. 8)
  3. Wait five minutes to clear out any gas, then smell for gas, including near the floor. If you smell gas, stop and follow the safety information on the label. (C-15958, p. 8)
  4. Turn the gas control knob counter-clockwise to PILOT, push it in and hold it while you press the piezo ignitor several times until the pilot lights. (C-15958, p. 8)
  5. Keep the knob pushed in for about 60 seconds after the pilot lights, or until you hear a beep, then release it. If the pilot goes out, repeat. If the knob does not pop up when released, stop and call your service technician or gas supplier. (C-15958, p. 8)
  6. Turn the gas control knob counter-clockwise to ON, flip the burner switch to ON and turn the HI/LO knob to the flame height you want. Check that all burner holes are lit. (C-15958, p. 9)
  7. Close the front control panel, turn the electric power back on and set the thermostat. (C-15958, p. 8)

Source: Enviro C-15958, p. 8; C-15958, p. 9; C-15958, p. 7

How do I turn on an E25I with the remote?

Press the ON/OFF key on the Proflame 2 transmitter. The controller beeps once, lights the pilot and then the main burner, which takes about 10 seconds. Don't try to light the pilot by hand. If ignition fails, the controller tries twice, each try lasting about 60 seconds with about 35 seconds between them, then locks out. When it is below 50°F (10°C) outside, Enviro recommends continuous pilot (CPI) mode, selected with the MODE key while the fireplace is off, to keep the chimney warm and cut condensation on the glass. The controller runs mainly on 120 V AC and can run on four AA backup batteries for shorter periods, such as a power outage.

Source: Enviro C-15958, p. 7; C-15958, p. 11; C-15958, p. 13; C-15958, p. 15; C-15958, p. 39

My E25I remote stopped working. How do I re-sync it?

Check the batteries first. The transmitter shows a battery icon when its three AAA batteries are low, and the controller (IFC) stops beeping at ON/OFF commands when its four AA backup batteries are low. If the transmitter is too far from the fireplace, use it closer. After changing batteries, sync the transmitter to the IFC again. The replacement Proflame 2 transmitter is part 50-3265. An E25ID has a Dexen remote instead, and C-15958 refers you to the separate Dexen user manual. Enviro's general Dexen manual, C-16359, which does not name the E25ID, pairs the remote by pressing the LEARN button on the control module and then the remote's POWER button.

  1. Turn off the main gas supply to the fireplace before you remove or reinsert the batteries in the battery holder. (C-15958, p. 10)
  2. Pull the sliding tray that holds the IFC and battery pack forward out of the cabinet. It has stops so the cables are not over-stretched. (C-15958, p. 12)
  3. Fit four AA batteries in the battery holder, matching the polarity marked on it, then press and release the IFC reset button. The IFC beeps three times when it is ready to sync. (C-15958, p. 13)
  4. With three AAA batteries in the transmitter, press its ON button. The IFC beeps four times to confirm it has accepted the transmitter's code. (C-15958, p. 13)
  5. Slide the tray back in with the cables under the clip at the back, and check that the wires do not touch the fan blades. (C-15958, p. 12)

Source: Enviro C-15958, p. 10; C-15958, p. 11; C-15958, p. 15; C-15958, p. 40; C-15958, p. 44; C-16359, p. 4

What do the flashing light codes mean on an E25I?

The LED on the Proflame 2 controller blinks a code in intervals. One blink means low battery (under 4 V). Two blinks mean a parasitic pilot flame. Three blinks mean the system has locked out, for example after it failed to ignite, and it stays locked out until it is reset. To reset, press ON/OFF on the transmitter, wait about 2 seconds and press it again. The manual also lists two other resets: turn the flame down to OFF with the down arrow and press the up arrow after about 2 seconds, or, with the transmitter off, disconnect the main power for a few seconds, reconnect it, wait about 2 seconds and press the reset button on the IFC. The manual says these codes don't apply to the E25ID and refers E25ID owners to the separate Dexen user manual for troubleshooting.

Source: Enviro C-15958, p. 39; C-15958, p. 40; C-15958, p. 41

How does the E25 fan work?

On the E25 the convection fan is optional. It comes on only once the fireplace is up to temperature, after about 15 minutes, and keeps running automatically for about 25 minutes after the fireplace is shut off. Change the speed with the fan control knob, and turn the knob counter-clockwise until it clicks to switch the fan off. Enviro advises against running the blower below 1/3 speed, as it strains the windings and can lead to early fan failure. On the E25I the fan is run from the remote: press MODE to reach the fan icon and use the arrow keys to pick one of six speeds.

Source: Enviro C-15958, p. 9; C-15958, p. 14

Why is the E25 glass foggy, and how do I clean it?

Condensation on the glass during a cold start is normal and clears once the fireplace warms up. Additives in the gas can also leave a haze. Clean the glass after the first burn, again about two weeks later, and then usually no more than two or three times a season. Use a mild glass cleaner and a soft cloth; abrasive cleaners damage the glass and painted surfaces.

  1. Let the fireplace cool completely. Never clean the glass when it is hot. (C-15958, p. 18)
  2. Release the two spring latches at the top of the door: put the hooked end of the door tool in the hole on each latch and pull it forward, then out to the side. (C-15958, p. 17)
  3. Tilt the top of the door forward and lift the door off. (C-15958, p. 17)
  4. Check that the gasket on the back of the glass is attached and intact, then clean the glass with a mild glass cleaner and a soft cloth. (C-15958, p. 18)
  5. Refit the door by reversing the steps. Never run the fireplace with the glass removed. (C-15958, p. 17)

Source: Enviro C-15958, p. 18; C-15958, p. 41

The E25 glass is cracked. What do I need?

Stop using the fireplace. The manual says not to run it with the glass front removed, cracked or broken. The glass is a high temperature ceramic and must be a factory replacement bought from an Enviro dealer. Removing and replacing the glass in the door must be done by a licensed or qualified service person; the replacement glass comes with a new gasket and is set in high temperature silicone. Wear gloves when handling a damaged door. The parts list gives 50-2506 for the glass and gasket and 50-3984 for the complete door assembly.

Source: Enviro C-15958, p. 18; C-15958, p. 44

Can I convert an E25 from natural gas to propane?

Yes, by a qualified service agency only. The NG to LP kit is 50-3981: a #52 orifice, an LP pilot orifice and conversion labels for the rating plate and the valve body. The LP to NG kit is 50-3982, with a #38 orifice, an NG pilot orifice and the same labels. On the E25I a stepper motor is ordered separately: 50-3753 for NG to LP or 50-3870 for LP to NG. On the E25 a screw in the Nova valve is flipped so the red o-ring shows for propane. The installer then leak-tests, checks the inlet and manifold pressures and fits the conversion label on or close to the rating label.

Source: Enviro C-15958, p. 20; C-15958, p. 21; C-15958, p. 22; C-15958, p. 44

Key specs

Gas input, natural gas
18,500 to 28,000 BTU/h (C-15958, p. 35)
Gas input, propane
22,500 to 28,000 BTU/h (C-15958, p. 35)
Manifold pressure (max)
3.6" W.C. natural gas, 10.0" W.C. propane (C-15958, p. 35)
Venting
3" intake and 3" exhaust aluminum or stainless steel flex vent to a vertical termination cap (C-15958, p. 25)
Vent length
10 to 40 ft (3.05 to 12.2 m) (C-15958, p. 25)
Horizontal termination
ICC TM-ALH (50-3664) or DuraVent 46DBA-HCL33, at least 6 ft of vent height above the cabinet (C-15958, p. 30)
Minimum fireplace opening
28" (711 mm) wide at the front, 20.8" (528 mm) at the back, 19.5" (495 mm) high, 13.5" (343 mm) deep (C-15958, p. 24)
Certified altitude
0 to 4,500 ft (1,372 m) (C-15958, p. 5)
Remote and controller (E25I)
Proflame 2 transmitter on three AAA batteries (315 MHz); IFC on 120 V AC with four AA backup batteries (C-15958, p. 10)

Need a part for your Enviro E25?

28 of 41 parts-list items are sold here.

Shop Enviro E25 parts
  • Enviro E25-D parts
Not sure which part? Find my part

Gas work, venting, electrical and glass replacement must be done by a qualified installer or service agency. These answers summarize Enviro's manuals; the manual for your exact model and serial number is the authority.

Enviro Fan Speed Control for EF2 / EF3 / EF4 / EF5 / Solus & Gas Fireplaces (EF-045) — OEM Enviro Part

Sale price $40.00 CAD Regular price $44.99 CAD

Enviro Insert EC-026 Fan Switch — Enviro Fireplace Parts

Enviro Burner / Rocker Switch - Many Models (EC-026)

Sale price $30.00 CAD Regular price $33.99 CAD

Enviro 50-3027 SIT Proflame 2 Battery Holder — Enviro Fireplace Parts

Enviro Remote Battery Holder (50-3027)

Sale price $41.82 CAD Regular price $46.99 CAD

Top Down Shot of Enviro Power Cord — Enviro Fireplace Parts

Enviro Fireplaces Power Cord Replacment - Most Models (EC-042)

Sale price $55.38 CAD Regular price $60.99 CAD

Enviro PSE Pilot Assembly MV - 50-4083 (50-3668/50-2513) — Enviro Fireplace Parts

Enviro PSE Nova Pilot Assembly - 50-4083 (50-3668/50-2513)

Sale price $130.00 CAD Regular price $143.99 CAD

See all Enviro E25 parts →
5
Battery holder (Dexen)
50-4156
$21.82 CAD →
66 V power adapter (Dexen)50-4157$53.33 CAD →
72-way Dexen pilot assembly50-4295$100.00 CAD →
–NG to LP stepper motor only (Dexen)50-4148$91.20 CAD →
–LP to NG stepper motor only (Dexen)50-4149$91.00 CAD →
, and 31 parts are tagged to fit the Enviro E25