Enviro Parts Only / One brand, every part
Search by Model / Find your exact unit
14-Day Returns / See our returns policy
Expert Advice / From people who care
Enviro Fireplace PartsEvery Enviro part, the right fit.
SupportWe're here to helpTrack OrderCheck status
Find My PartFind the right fit
  • Models
  • Find My Part
  • Manuals
  • Contact
Menu
  • Models
  • Find My Part
  • Manuals
  • Contact
Enviro Fireplace PartsEvery Enviro part, the right fit.
Find My Part Request a Part
Enviro Fireplace Parts

Every Enviro part, the right fit.

Get fitment tips, restock alerts, and Enviro parts news — straight to your inbox.

Shop

  • Shop by Model
  • Shop by Category
  • All Parts

Parts by Appliance

  • Wood Stove Parts
  • Gas Fireplace Parts
  • Pellet Stove Parts

Help & Support

  • Find My Part
  • Request a Part
  • Help Centre
  • Shipping & Delivery
  • Returns & Refunds
  • Warranty

Company

  • About Us
  • Contact Us
  • Blog

© 2026 Enviro Fireplace Parts. All rights reserved.

Enviro Fireplace Parts is operated by Friendly Fires Inc. · (705) 741-1900

PrivacyTermsAccessibility
  • Home
  • Models
  • Parts
  • Support
  • Cart
  1. Home
  2. Manuals
  3. Enviro Milan

Manuals & parts · Pellet fireplace insert (discontinued)

Enviro Milan Manuals

Quick answer

The Enviro Milan is a discontinued pellet fireplace insert, and Enviro lists all of its manuals as archived. The last editions are the Milan owner's manual C-13849 and the Milan technical manual C-12153, which are meant to be used together and are free PDFs from enviro.com. Milan parts are still sold here; the rating label is on the hopper top, behind the surround panel.

Every Milan owner's and technical manual Enviro still publishes, the factory parts list with part numbers, key specs, and answers to common Milan questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the Milan, but we still sell its parts.

Last updated Nov 25, 2026 · From Enviro docs C-13849, C-12153, C-11419 and C-11418 · Answers drafted from the manuals; staff review pending

Shop Enviro Milan partsGet the manual

Which Enviro Milan do I have?

Milan FPI, thermostat switch control board

Milan insert with a thermostat switch (manual, high/low and auto/off) and feed rate and combustion blower trim buttons on the control board. Owner's manuals from October 2009, with technical manuals C-12153 (from March 2010) and C-11921, whose parts list leaves the board numbers blank. The last manuals are listed to May 1, 2020.

Manuals: C-13849, C-12153, C-12144, C-11920, C-11921

Milan FPI, first control board

The 2007 Milan, whose control panel has an ON/OFF button, an auger pulse light, the heat output indicator and heat level button, with the auger trim on the motherboard behind the surround panel. Its parts list gives different circuit boards and convection blower number.

Manuals: C-11418, C-11419, C-11921

Find your model and serial number: The rating label is on the hopper top, behind the surround panel. (Enviro C-13849, p. 3)

Diagram of an Enviro Milan showing where the rating label with the model and serial number is: On the Enviro Milan insert the rating label is on the hopper top, behind the surround panel.
Where to find the Enviro Milan rating label. Our diagram, based on Enviro C-13849 p. 3.
Chart of Enviro Milan versions: Milan FPI, thermostat switch control board, Milan FPI, first control board, with what sets each one apart.
Enviro Milan versions at a glance. Our chart, from the Enviro manuals listed below.

Enviro Milan parts from the manual, sold here

Enviro Ceramic Fan Sensor (EC-001) — Enviro Fireplace Parts

Enviro Ceramic Fan Sensor (EC-001)

Sale price $77.79 CAD Regular price $85.99 CAD

Top Down Shot of Enviro Power Cord — Enviro Fireplace Parts

Enviro Fireplaces Power Cord Replacment - Most Models (EC-042)

Sale price $55.38 CAD Regular price $60.99 CAD

Enviro Heyco Strain Relief - Many Models (EC-044) — Enviro Fireplace Parts

Enviro Heyco Strain Relief - Many Models (EC-044)

Sale price $73.29 CAD Regular price $80.99 CAD

EF-001 (1) — Enviro Fireplace Parts

Enviro Milan owner's and installation manuals

Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.

The Enviro Milan is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro Milan parts.

Archived Enviro Milan manuals (7)
  • Milan Domestic Owner's Manual

    C-13849 · Mar 6, 2013 – May 01, 2020

    PDF
  • Milan Domestic Technical Manual

    C-12153 · Mar 1, 2010 – May 01, 2020

    PDF
  • Milan Domestic Owner's Manual

    C-12144 · Mar 1, 2010 – Mar 06, 2013

    PDF
  • Milan Domestic Owner's Manual

    C-11920 · Oct 15, 2009 – Mar 01, 2010

    PDF
  • Milan Domestic Technical Manual

    C-11921 · May 20, 2009 – Mar 01, 2010

    PDF
  • Milan Domestic Owner's Manual

    C-11418 · Aug 27, 2007 – Oct 15, 2009

    PDF
  • Milan Domestic Technical Manual

    C-11419 · Aug 27, 2007 – May 20, 2009

    PDF

Can't open a link? Enviro lists every version on its manuals pages: Enviro Milan manuals, Enviro legacy manuals.

Enviro Milan parts list, with part numbers

From the parts lists in the Enviro Milan manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.

Milan FPI insert (Enviro C-12153, p. 16)

RefPartPart #Our store
1Ceramic fan temperature sensor, 120 °F (49 °C)EC-001$77.79 CAD →
–Domestic power cord, 115 VEC-042$55.38 CAD →
–Heyco strain reliefEC-044$73.29 CAD →
2Auger motor, 115 VEF-001$166.67 CAD →
3Convection blower, 115 VEF4i-002Request it
3Convection blower impellerEF-004$114.58 CAD →
3Convection blower insulator gasketEF-006$10.99 CAD →
4High limit temperature sensor, 200 °F (93 °C), manual resetEF-016$79.80 CAD →
5Silicone hoseEF-018$38.00 CAD →
–Pellet stove cleaning brushEF-156$36.83 CAD →
–Auger brass bushing (set of 2)EF4i-065Request it
–5/8" door gasket, 7 ft (2.1 m)50-088$56.67 CAD →
6Brick panel retainers (set of 2)50-185Request it
7Ignitor, 400 W, 115 V50-619$56.67 CAD →
8Circuit board 5 A fuses, 115 V (pair)50-833$40.91 CAD →
9Combustion / exhaust blower assembly, 115 V50-901Request it
9Combustion / exhaust blower mounting gasketEF-011$53.20 CAD →
9Combustion / exhaust blower housing gasketEF-012$52.00 CAD →
9Combustion / exhaust blower formed housing50-1107Request it
–5/8" ID auger collar with screw50-968$65.11 CAD →
–Burn pot scraper tool50-1254Request it
10Auger, 115 V50-1346Request it
11Auger plate with bushing50-1359$134.76 CAD →
12Burn pot, 1.5" intake hole50-1366$153.67 CAD →
13Vacuum switch, low pressure50-1390$130.00 CAD →
14Exhaust starter tube, 3" quick connect50-1391Request it
15Mother board, 120 V50-2089$363.17 CAD →
16Daughter board, 120 V50-2090$112.78 CAD →
17Slider damper and lever50-1394Request it
18Exhaust starter elbow, quick connect50-1395Request it
19Exhaust starter gasket50-1396$60.00 CAD →
20Daughter board control panel with decal50-2091$82.98 CAD →
21Ignitor and intake tube50-1398Request it
22Cast brick panel set50-1399Request it
23Inner door complete with glass and tape50-1400Request it
24Burn pot liner with sides50-1401$108.57 CAD →
25Door bolt, hardened bushing and nut50-1465$52.85 CAD →
26Inner door handle50-1467Request it
27Glass with tape50-1468$286.43 CAD →
–Inner door hinge50-1530Request it
–Wiring harness50-1550$130.00 CAD →
–Milan Domestic Owner's Manual, 115 V50-1718Request it
–Milan Domestic Technical Manual, 115 V50-1719Request it
28Milan cast top (hopper lid)50-1720Request it
29Milan cast bottom50-1721Request it
30Milan cast door handle50-1722Request it
31Milan surround panel50-1723Request it
32Milan riser skirtoption50-1724Request it
33Milan outer door50-1725Request it
34Milan outer door magnet50-1726Request it
35Milan outer door hinge pin50-1727Request it
36Milan side grill assembly, right50-1728Request it
37Milan side grill assembly, left50-1729Request it
38Ash pan latch50-1730$61.67 CAD →
39Leveling legs, 3" (set of 4)50-1731Request it

Milan FPI, first control board (2007 technical manual), differences (Enviro C-11419, p. 16)

RefPartPart #Our store
3Convection blower, 115 VEF-002$218.17 CAD →
15Mother board, 120 V50-1392Request it
16Daughter board, 120 V50-1393Request it
20Daughter board decal50-1397

Enviro Milan questions, answered from the manual

Where is the serial number on an Enviro Milan?

On the rating label, which is on the hopper top behind the surround panel. To reach it, lift the cast top (it comes up and forward), then lift the surround panel up and out. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.

Source: Enviro C-13849, p. 3; C-12153, p. 10; C-13849, p. 14

Which Milan manual do I need?

The Milan is discontinued and Enviro lists every Milan document as archived. Use the last owner's manual, C-13849 (March 6, 2013), together with the technical manual C-12153: the owner's manual is meant for the home owner and the technical manual for the technician, and the technical manual holds the rating label, installation steps, troubleshooting, wiring diagram and parts list. A 2007 to 2009 Milan with the first control board (auger pulse light, no thermostat switch) matches the archived manuals C-11418 and C-11419.

Source: Enviro C-13849, p. 3; C-12153, p. 3; C-12153, p. 2; C-11418, p. 7; C-13849, p. 14; C-11418, p. 16

How do I start an Enviro Milan pellet insert?

With a clean burn pot liner seated against the ignitor tube, pellets in the hopper and the thermostat switch on MANUAL, press the ON/OFF button. You can change the heat level during start-up, but it only takes effect once start-up is finished. On the first start, or after running out of fuel, prime the auger by restarting five minutes into start-up or by putting a small handful of pellets in the burn pot. After about 10 to 15 minutes the stove runs at the set heat level and the room air blower comes on.

  1. Check that the burn pot liner holes are clear and the liner sits against the ignitor tube, and that there are enough pellets in the hopper. Never run the insert with the door or ash pan open. (C-13849, p. 7)
  2. Set the thermostat switch to MANUAL and press the ON/OFF button. The heat level indicator shows the level the stove will run at after start-up. (C-13849, p. 7)
  3. On the first start, or after the insert ran out of fuel, prime the auger: restart the stove five minutes into its start-up, or put a small handful of pellets into the burn pot. (C-13849, p. 7)
  4. After about 10 to 15 minutes the insert switches from start-up to the selected heat level and the convection (room air) blower turns on. (C-13849, p. 7)

Source: Enviro C-13849, p. 7

How do I turn off a Milan, and what do the thermostat modes do?

In MANUAL or HIGH/LOW mode, press the ON/OFF button: the pellet feed stops and the blowers keep running until the insert is cool enough to turn off. In AUTO/OFF mode, turn the thermostat down or off; the insert runs on low for three minutes before it turns off. Do not unplug it while the combustion fan is running, as smoke may escape. HIGH/LOW (needs a thermostat): when the thermostat is satisfied, the heat level and fans drop to LOW until it calls for heat again. AUTO/OFF (needs a thermostat): when the thermostat calls, the insert lights itself; when it is satisfied the insert drops to LOW for 30 minutes and then shuts down unless the thermostat calls again. The installer connects a 12 or 24 volt thermostat with 18 x 2 gauge wire in place of the jumper wire.

Source: Enviro C-13849, p. 8; C-12153, p. 7

What do the flashing lights on a Milan mean?

Light #2 flashing on the heat output bar: the 200 °F (93 °C) high limit sensor on the hopper has tripped and the auger has stopped. Your dealer has to reset the manual-reset switch and find out why the insert overheated; the technical manual suggests testing the convection blower. Light #3 flashing: no fire is detected or the fire has gone out, because the exhaust temperature sensor's contacts opened; check the hopper for fuel, clean the burn pot liner and check the damper setting. If the vacuum switch sees a blocked vent or ash build-up in the burn pot, it stops the auger and the insert shuts off. Push the ON/OFF button to reset the board after a trouble code. Enviro says troubleshooting should be done by qualified technicians or installers.

Source: Enviro C-13849, p. 9; C-12153, p. 12; C-12153, p. 13

How do I fine-tune a Milan for my pellets?

If the insert builds up on all settings, pull the slider damper rod out in small steps for more air. If ash builds up in the liner on the low feed settings, raise the combustion blower trim one setting at a time (factory setting #2); if the fire goes out on low because there is too much airflow, lower it to #1. If ash builds up on the high settings, lower the feed rate trim one setting at a time (factory setting #4). With long pellets, mostly over 1" (2.5cm), you can move the feed rate trim up to #5, but only if the fuel burns without building up. To change a trim, hold its trim button and press the heat level up or down buttons. The slider damper itself must be set at installation by a qualified service technician or installer.

Source: Enviro C-13849, p. 8; C-13849, p. 7; C-13849, p. 9

How do I clean the Milan burn pot?

Every two to three days, with the insert cold, take out the burn pot liner and scrape its holes clear. A dirty liner can let fuel build up past the liner and up the drop tube, jamming the auger, and pellets may then burn in the drop tube and hopper.

  1. Let the insert go completely cold, then open the door on the right-hand side and swing it open. (C-13849, p. 10)
  2. Lift the liner out of the burn pot. Lift the front of the burn pot and slide the assembly off the air intake tube and the ignitor cartridge. (C-13849, p. 10)
  3. With a metal scraper, clear the material built up in or clogging the liner holes, then empty the ash from the liner and the burn pot. (C-13849, p. 10)
  4. Put the burn pot back with the pipes properly inserted, then set the liner in with its ignitor hole lined up with the ignitor tube, pushed up against the tube. (C-13849, p. 10)

Source: Enviro C-13849, p. 10

How do I clean the exhaust passages behind the Milan firebox?

Each season, take out the firebox backing panels and vacuum behind them. Lubricate the screws with penetrating oil before removing them.

  1. With the insert cold, open the door by lifting the handle and remove the burn pot and burn pot liner. (C-13849, p. 11)
  2. Lubricate all the screws with penetrating oil, then remove the two screws holding each brick liner retainer. (C-13849, p. 11)
  3. Slide the side brick liners forward and out, then pull the center panel out. (C-13849, p. 11)
  4. Vacuum and clean thoroughly. (C-13849, p. 11)
  5. Put the center panel back, then the two side panels, and refit the two retainers with two screws on each side. Replace the burn pot and liner and close the door. (C-13849, p. 11)

Source: Enviro C-13849, p. 11

What maintenance does an Enviro Milan need?

Every 2 to 3 days: the burn pot and liner, the door latch and the ash pan (empty it into a metal container and vacuum with a fine filter bag). Weekly: the ash pan and door gaskets, and the heat exchanger fins inside the firebox, brushed off. Each season: the fresh air intake, the exhaust passages, the hinges and the two blowers (unplug the insert, pull it out, vacuum the motors and lubricate the convection motor). The owner's manual gives two intervals for the exhaust vent, semi-annually or every two tons of pellets, and every year or after two tons; Enviro recommends a dealer for it. At the end of the season run the insert out of fuel and unplug it.

Source: Enviro C-13849, p. 10; C-13849, p. 11; C-13849, p. 12; C-13849, p. 4

How do I clean the Milan glass, and which part replaces it?

Clean the glass only when the insert is cold: wipe it with a dry soft cloth, and for build-up use a paper towel with a glass cleaner, or a damp paper towel dipped in fly ash, then wipe dry. Never run the insert with broken glass; Enviro recommends your dealer replace it. The door glass is high temperature pyro ceramic, 5 mm thick, 18.5 x 13.5 inches (470 mm x 343 mm). The owner's manual names part 50-1400, which the parts list calls the inner door complete with glass and tape; the parts list gives 50-1468 for the glass with tape alone.

Source: Enviro C-13849, p. 10; C-13849, p. 5; C-13849, p. 12; C-12153, p. 17

Key specs

Input rating
12,000 to 36,000 BTU/h (3.5 to 10.5 kW) (rating label) (C-12153, p. 5)
Fuel
Wood pellets only, up to 3% ash content; cordwood is prohibited (C-13849, p. 4)
Electrical
110 to 120 V (4.1 A), 60 Hz, grounded outlet; 500 W maximum (C-13849, p. 5)
Venting (Canada and USA)
Continuous 3" or 4" diameter chimney liner from the insert to the top of the chimney, meeting type 3 of CAN/ULC S635 (C-12153, p. 8)
Venting without a full reline (USA only)
Positive flue connection: the vent connector extends at least 18" above a sealed chimney plate (C-12153, p. 9)
Clearances
24" (61.0 cm) side wall to centre of unit; 3" (7.6 cm) side wall to surround; 12" (30.5 cm) mantel at least 36" (91.4 cm) above the bottom of the unit; 0" to top and side facing (C-12153, p. 7)
Floor protection
Non-combustible material 6" (15.2 cm) in front and to each side of the unit (C-12153, p. 7)
Hopper back height
Three settings: 503 mm, 529 mm or 554 mm; use the highest the fireplace allows (C-12153, p. 10)
Thermostat
12 or 24 V wall thermostat on 18 x 2 gauge wire (C-12153, p. 7)
Door glass
5 mm pyro ceramic, 18.5 x 13.5 in (470 x 343 mm) (C-13849, p. 12)

Need a part for your Enviro Milan?

29 of 60 parts-list items are sold here.

Shop Enviro Milan partsNot sure which part? Find my part

Gas work, venting, electrical and glass replacement must be done by a qualified installer or service agency. These answers summarize Enviro's manuals; the manual for your exact model and serial number is the authority.

Enviro Pellet Auger Motor - Genuine Part - Heavy Duty (EF-001)

Sale price $166.67 CAD Regular price $183.99 CAD

EF-004 - Enviro Impeller - Convection Blower ( Meridian / EF2 / EF3 / Empress Insert ) — Enviro Fireplace Parts

Enviro Impeller for Convection Blower - Meridian/EF2/EF3/Empress (EF-004)

Sale price $114.58 CAD Regular price $126.99 CAD

Enviro Convection Blower Gasket (EF-006) — Enviro Fireplace Parts

Enviro Convection Blower Gasket (EF-006)

Sale price $10.99 CAD Regular price $12.99 CAD

Enviro EF-016 High Limit Sensor — Enviro Fireplace Parts

Enviro Pellet Stoves High Temperature Sensor (EF-016)

Sale price $79.80 CAD Regular price $87.99 CAD

EF-018 - Enviro Silicone Hose - Red (Meridian/EF2/3....) — Enviro Fireplace Parts

Enviro Silicone Hose - Red - Meridian / EF2 / EF3 .... (EF-018)

Sale price $38.00 CAD Regular price $41.99 CAD

See all Enviro Milan parts →
$80.38 CAD →
20Daughter board control panel with decal50-1514Request it
, and 20 parts are tagged to fit the Enviro Milan