Manuals & parts · Pellet fireplace insert (discontinued)
Quick answer
The Enviro Milan is a discontinued pellet fireplace insert, and Enviro lists all of its manuals as archived. The last editions are the Milan owner's manual C-13849 and the Milan technical manual C-12153, which are meant to be used together and are free PDFs from enviro.com. Milan parts are still sold here; the rating label is on the hopper top, behind the surround panel.
Every Milan owner's and technical manual Enviro still publishes, the factory parts list with part numbers, key specs, and answers to common Milan questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the Milan, but we still sell its parts.
Last updated · From Enviro docs C-13849, C-12153, C-11419 and C-11418 · Answers drafted from the manuals; staff review pending
Milan FPI, thermostat switch control board
Milan insert with a thermostat switch (manual, high/low and auto/off) and feed rate and combustion blower trim buttons on the control board. Owner's manuals from October 2009, with technical manuals C-12153 (from March 2010) and C-11921, whose parts list leaves the board numbers blank. The last manuals are listed to May 1, 2020.
Manuals: C-13849, C-12153, C-12144, C-11920, C-11921
Milan FPI, first control board
The 2007 Milan, whose control panel has an ON/OFF button, an auger pulse light, the heat output indicator and heat level button, with the auger trim on the motherboard behind the surround panel. Its parts list gives different circuit boards and convection blower number.
Manuals: C-11418, C-11419, C-11921
Find your model and serial number: The rating label is on the hopper top, behind the surround panel. (Enviro C-13849, p. 3)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro Milan is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro Milan parts.
Milan Domestic Owner's Manual
C-13849 · Mar 6, 2013 – May 01, 2020
Milan Domestic Technical Manual
C-12153 · Mar 1, 2010 – May 01, 2020
Milan Domestic Owner's Manual
C-12144 · Mar 1, 2010 – Mar 06, 2013
Milan Domestic Owner's Manual
C-11920 · Oct 15, 2009 – Mar 01, 2010
Milan Domestic Technical Manual
C-11921 · May 20, 2009 – Mar 01, 2010
Milan Domestic Owner's Manual
C-11418 · Aug 27, 2007 – Oct 15, 2009
Milan Domestic Technical Manual
C-11419 · Aug 27, 2007 – May 20, 2009
Can't open a link? Enviro lists every version on its manuals pages: Enviro Milan manuals, Enviro legacy manuals.
From the parts lists in the Enviro Milan manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Ceramic fan temperature sensor, 120 °F (49 °C) | EC-001 | $77.79 CAD → |
| – | Domestic power cord, 115 V | EC-042 | $55.38 CAD → |
| – | Heyco strain relief | EC-044 | $73.29 CAD → |
| 2 | Auger motor, 115 V | EF-001 | $166.67 CAD → |
| 3 | Convection blower, 115 V | EF4i-002 | Request it |
| 3 | Convection blower impeller | EF-004 | $114.58 CAD → |
| 3 | Convection blower insulator gasket | EF-006 | $10.99 CAD → |
| 4 | High limit temperature sensor, 200 °F (93 °C), manual reset | EF-016 | $79.80 CAD → |
| 5 | Silicone hose | EF-018 | $38.00 CAD → |
| – | Pellet stove cleaning brush | EF-156 | $36.83 CAD → |
| – | Auger brass bushing (set of 2) | EF4i-065 | Request it |
| – | 5/8" door gasket, 7 ft (2.1 m) | 50-088 | $56.67 CAD → |
| 6 | Brick panel retainers (set of 2) | 50-185 | Request it |
| 7 | Ignitor, 400 W, 115 V | 50-619 | $56.67 CAD → |
| 8 | Circuit board 5 A fuses, 115 V (pair) | 50-833 | $40.91 CAD → |
| 9 | Combustion / exhaust blower assembly, 115 V | 50-901 | Request it |
| 9 | Combustion / exhaust blower mounting gasket | EF-011 | $53.20 CAD → |
| 9 | Combustion / exhaust blower housing gasket | EF-012 | $52.00 CAD → |
| 9 | Combustion / exhaust blower formed housing | 50-1107 | Request it |
| – | 5/8" ID auger collar with screw | 50-968 | $65.11 CAD → |
| – | Burn pot scraper tool | 50-1254 | Request it |
| 10 | Auger, 115 V | 50-1346 | Request it |
| 11 | Auger plate with bushing | 50-1359 | $134.76 CAD → |
| 12 | Burn pot, 1.5" intake hole | 50-1366 | $153.67 CAD → |
| 13 | Vacuum switch, low pressure | 50-1390 | $130.00 CAD → |
| 14 | Exhaust starter tube, 3" quick connect | 50-1391 | Request it |
| 15 | Mother board, 120 V | 50-2089 | $363.17 CAD → |
| 16 | Daughter board, 120 V | 50-2090 | $112.78 CAD → |
| 17 | Slider damper and lever | 50-1394 | Request it |
| 18 | Exhaust starter elbow, quick connect | 50-1395 | Request it |
| 19 | Exhaust starter gasket | 50-1396 | $60.00 CAD → |
| 20 | Daughter board control panel with decal | 50-2091 | $82.98 CAD → |
| 21 | Ignitor and intake tube | 50-1398 | Request it |
| 22 | Cast brick panel set | 50-1399 | Request it |
| 23 | Inner door complete with glass and tape | 50-1400 | Request it |
| 24 | Burn pot liner with sides | 50-1401 | $108.57 CAD → |
| 25 | Door bolt, hardened bushing and nut | 50-1465 | $52.85 CAD → |
| 26 | Inner door handle | 50-1467 | Request it |
| 27 | Glass with tape | 50-1468 | $286.43 CAD → |
| – | Inner door hinge | 50-1530 | Request it |
| – | Wiring harness | 50-1550 | $130.00 CAD → |
| – | Milan Domestic Owner's Manual, 115 V | 50-1718 | Request it |
| – | Milan Domestic Technical Manual, 115 V | 50-1719 | Request it |
| 28 | Milan cast top (hopper lid) | 50-1720 | Request it |
| 29 | Milan cast bottom | 50-1721 | Request it |
| 30 | Milan cast door handle | 50-1722 | Request it |
| 31 | Milan surround panel | 50-1723 | Request it |
| 32 | Milan riser skirtoption | 50-1724 | Request it |
| 33 | Milan outer door | 50-1725 | Request it |
| 34 | Milan outer door magnet | 50-1726 | Request it |
| 35 | Milan outer door hinge pin | 50-1727 | Request it |
| 36 | Milan side grill assembly, right | 50-1728 | Request it |
| 37 | Milan side grill assembly, left | 50-1729 | Request it |
| 38 | Ash pan latch | 50-1730 | $61.67 CAD → |
| 39 | Leveling legs, 3" (set of 4) | 50-1731 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 3 | Convection blower, 115 V | EF-002 | $218.17 CAD → |
| 15 | Mother board, 120 V | 50-1392 | Request it |
| 16 | Daughter board, 120 V | 50-1393 | Request it |
| 20 | Daughter board decal | 50-1397 |
On the rating label, which is on the hopper top behind the surround panel. To reach it, lift the cast top (it comes up and forward), then lift the surround panel up and out. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-13849, p. 3; C-12153, p. 10; C-13849, p. 14
The Milan is discontinued and Enviro lists every Milan document as archived. Use the last owner's manual, C-13849 (March 6, 2013), together with the technical manual C-12153: the owner's manual is meant for the home owner and the technical manual for the technician, and the technical manual holds the rating label, installation steps, troubleshooting, wiring diagram and parts list. A 2007 to 2009 Milan with the first control board (auger pulse light, no thermostat switch) matches the archived manuals C-11418 and C-11419.
Source: Enviro C-13849, p. 3; C-12153, p. 3; C-12153, p. 2; C-11418, p. 7; C-13849, p. 14; C-11418, p. 16
With a clean burn pot liner seated against the ignitor tube, pellets in the hopper and the thermostat switch on MANUAL, press the ON/OFF button. You can change the heat level during start-up, but it only takes effect once start-up is finished. On the first start, or after running out of fuel, prime the auger by restarting five minutes into start-up or by putting a small handful of pellets in the burn pot. After about 10 to 15 minutes the stove runs at the set heat level and the room air blower comes on.
Source: Enviro C-13849, p. 7
In MANUAL or HIGH/LOW mode, press the ON/OFF button: the pellet feed stops and the blowers keep running until the insert is cool enough to turn off. In AUTO/OFF mode, turn the thermostat down or off; the insert runs on low for three minutes before it turns off. Do not unplug it while the combustion fan is running, as smoke may escape. HIGH/LOW (needs a thermostat): when the thermostat is satisfied, the heat level and fans drop to LOW until it calls for heat again. AUTO/OFF (needs a thermostat): when the thermostat calls, the insert lights itself; when it is satisfied the insert drops to LOW for 30 minutes and then shuts down unless the thermostat calls again. The installer connects a 12 or 24 volt thermostat with 18 x 2 gauge wire in place of the jumper wire.
Source: Enviro C-13849, p. 8; C-12153, p. 7
Light #2 flashing on the heat output bar: the 200 °F (93 °C) high limit sensor on the hopper has tripped and the auger has stopped. Your dealer has to reset the manual-reset switch and find out why the insert overheated; the technical manual suggests testing the convection blower. Light #3 flashing: no fire is detected or the fire has gone out, because the exhaust temperature sensor's contacts opened; check the hopper for fuel, clean the burn pot liner and check the damper setting. If the vacuum switch sees a blocked vent or ash build-up in the burn pot, it stops the auger and the insert shuts off. Push the ON/OFF button to reset the board after a trouble code. Enviro says troubleshooting should be done by qualified technicians or installers.
Source: Enviro C-13849, p. 9; C-12153, p. 12; C-12153, p. 13
If the insert builds up on all settings, pull the slider damper rod out in small steps for more air. If ash builds up in the liner on the low feed settings, raise the combustion blower trim one setting at a time (factory setting #2); if the fire goes out on low because there is too much airflow, lower it to #1. If ash builds up on the high settings, lower the feed rate trim one setting at a time (factory setting #4). With long pellets, mostly over 1" (2.5cm), you can move the feed rate trim up to #5, but only if the fuel burns without building up. To change a trim, hold its trim button and press the heat level up or down buttons. The slider damper itself must be set at installation by a qualified service technician or installer.
Source: Enviro C-13849, p. 8; C-13849, p. 7; C-13849, p. 9
Every two to three days, with the insert cold, take out the burn pot liner and scrape its holes clear. A dirty liner can let fuel build up past the liner and up the drop tube, jamming the auger, and pellets may then burn in the drop tube and hopper.
Source: Enviro C-13849, p. 10
Each season, take out the firebox backing panels and vacuum behind them. Lubricate the screws with penetrating oil before removing them.
Source: Enviro C-13849, p. 11
Every 2 to 3 days: the burn pot and liner, the door latch and the ash pan (empty it into a metal container and vacuum with a fine filter bag). Weekly: the ash pan and door gaskets, and the heat exchanger fins inside the firebox, brushed off. Each season: the fresh air intake, the exhaust passages, the hinges and the two blowers (unplug the insert, pull it out, vacuum the motors and lubricate the convection motor). The owner's manual gives two intervals for the exhaust vent, semi-annually or every two tons of pellets, and every year or after two tons; Enviro recommends a dealer for it. At the end of the season run the insert out of fuel and unplug it.
Source: Enviro C-13849, p. 10; C-13849, p. 11; C-13849, p. 12; C-13849, p. 4
Clean the glass only when the insert is cold: wipe it with a dry soft cloth, and for build-up use a paper towel with a glass cleaner, or a damp paper towel dipped in fly ash, then wipe dry. Never run the insert with broken glass; Enviro recommends your dealer replace it. The door glass is high temperature pyro ceramic, 5 mm thick, 18.5 x 13.5 inches (470 mm x 343 mm). The owner's manual names part 50-1400, which the parts list calls the inner door complete with glass and tape; the parts list gives 50-1468 for the glass with tape alone.
Source: Enviro C-13849, p. 10; C-13849, p. 5; C-13849, p. 12; C-12153, p. 17
Sale price $166.67 CAD Regular price $183.99 CAD
| $80.38 CAD → |