Quick answer
The current Enviro Maxx manual is C-15414 R1, the Maxx-1 Domestic Owner's Manual, a free PDF from enviro.com; C-14699 covers the optional Heat Distribution Kit. Stoves bought before October 2020 are covered by the archived Maxx-1 owner's manuals going back to 2010, so pick the one whose dates match your purchase. The rating label is on the inside of the hopper.
Owner's manuals for the Enviro Maxx-1 freestanding pellet stove since 2010, the Heat Distribution Kit manual, the factory parts list with part numbers, key specs, and answers to common Maxx questions, each taken from the official Enviro manual with the page number.
Last updated · From Enviro docs C-15414 rev R1 and C-14699 rev R2 · Answers drafted from the manuals; staff review pending
Which Enviro Maxx do I have?
Maxx-1 (Oct 2020 onward)
Freestanding Maxx-1 pellet stove covered by the current owner's manual. This revision states EPA certification to the 2020 particulate emission standards and a heat output range of 16,588 to 63,386 BTU/h.
Manuals: C-15414
Maxx-1 (2010 to 2020)
Earlier Maxx-1 stoves. Use the archived owner's manual whose validity dates cover your purchase date. From 2013 to 2015 Enviro also published a separate Maxx-1 technical manual.
Manuals: C-15414, C-14596, C-13846, C-12214, C-12215
Maxx-1 with HDK
Maxx-1 fitted with the optional Heat Distribution Kit, which adds outlets for 4" heat ducts. The stove must run in Hi/Lo or Auto/Off mode for the kit to work.
Manuals: C-14699
Find your model and serial number: The rating label is on the inside of the hopper. (Enviro C-15414, p. 3)
Enviro Maxx owner's and installation manuals
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
Maxx-1 Domestic Owner's Manual R1
C-15414 rev R1 · Oct 1, 2020 – Present · 36 pages · Current
Maxx-1 Heat Distribution Kit (HDK) Manual R2
C-14699 rev R2 · Jul 17, 2015 – Present · 12 pages · Current
Older Enviro Maxx manuals (5)
Maxx-1 Domestic Owner's Manual
C-15414 · May 3, 2018 – Oct 01 2020
Maxx-1 Domestic Owner's Manual
C-14596 · May 1, 2015 – May 03, 2018
Maxx-1 Domestic Technical Manual
C-12215 · Jul 24, 2013 – May 1, 2015
Maxx-1 Domestic Owner's Manual
C-13846 · Mar 6, 2013 – May 1, 2015
Maxx-1 Domestic Owner's Manual
C-12214 · Jun 9, 2010 – Mar 06, 2013
Can't open a link? Enviro lists every version on its manuals pages: Enviro Maxx FS manuals.
Enviro Maxx parts list, with part numbers
From the parts lists in the Enviro Maxx manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
Maxx-1 freestanding (Enviro C-15414, p. 30)
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | 120 °F (49 °C) ceramic fan temperature sensor | EC-001 | $77.79 CAD → |
| 2 | IEC power cord (115 V) | EC-043 | $76.90 CAD → |
| – | Window channel tape, 6 ft (1.8 m) | EC-058 | Request it |
| 3 | High limit temperature sensor, 200 °F (93 °C), manual reset | EF-016 | $79.80 CAD → |
| – | Silicone hose | EF-018 | $38.00 CAD → |
| 4 | Slider damper rod with knob | EF-050 | $71.62 CAD → |
| 5 | Glass, large (9" x 13", 229 x 330 mm) | EF-061 | $172.20 CAD → |
| 6 | 1" knob | EF-068 | $68.10 CAD → |
| 7 | Shoulder bolt, roller and nut (set of 2) | EF-124 | $69.64 CAD → |
| – | Pellet stove cleaning brush | EF-156 | $36.83 CAD → |
| – | Ash pan gasket, 10 ft (3.0 m) | EF-208 | $52.00 CAD → |
| – | Door gasket, 3/4" firm round, 80" (7 ft, 2.1 m) | EF4i-056 | $63.84 CAD → |
| 8 | Auger brass bushings (set of 2) | EF4i-065 | Request it |
| 9 | IEC power cord inlet socket | 50-713 | Request it |
| 10 | Circuit board 5 A fuse, 115 V (set of 2) | 50-833 | $40.91 CAD → |
| 11 | 5/8" ID auger collar with screw | 50-968 | $65.11 CAD → |
| 14 | Auger with paddles | 50-1161 | $192.73 CAD → |
| – | Burn pot scraper tool | 50-1254 | Request it |
| 15 | Leveling legs, 1 1/2" (set of 4) | 50-1342 | Request it |
| 16 | Vacuum switch, low pressure | 50-1390 | $130.00 CAD → |
| – | Auger tube cover | 50-1410 | Request it |
| 17 | 4" exhaust starter tube gasket | 50-1913 | Request it |
| – | Control panel decal | 50-1482 | $80.38 CAD → |
| – | Maxx domestic owner's manual | 50-1531 | Request it |
| – | Maxx domestic technical manual | 50-1532 | Request it |
| – | 600 W backup systemoption | 50-1547 | Request it |
| 18 | Auger stops (clear rubber) | 50-1559 | Request it |
| 20 | Maxx door, large glass | 50-1632 | Request it |
| 21 | Hopper lid hinge, left | 50-1633 | Request it |
| 22 | Hopper lid hinge, right | 50-1634 | Request it |
| 23 | Hopper lid | 50-1635 | Request it |
| 24 | Trivet | 50-1636 | $156.04 CAD → |
| 25 | Top front with mount | 50-1637 | Request it |
| 26 | Heat exchanger rod | 50-1638 | $77.20 CAD → |
| 27 | Back grill, top | 50-1639 | Request it |
| 28 | Back grill, bottom | 50-1640 | Request it |
| 29 | Cabinet side, left | 50-1641 | $234.07 CAD → |
| 30 | Cabinet side, right | 50-1642 | Request it |
| 31 | Louver assembly | 50-1643 | Request it |
| 32 | Slider damper plate | 50-1644 | $87.49 CAD → |
| 33 | Firebox baffle | 50-1645 | $94.23 CAD → |
| 34 | Ash pan | 50-1646 | $209.23 CAD → |
| 35 | Ash pan cover | 50-1647 | Request it |
| 37 | Glass retainer, large | 50-1649 | Request it |
| 39 | Inner door, large (no glass) | 50-1651 | Request it |
| 40 | Door handle, upper | 50-1652 | Request it |
| 41 | Door handle, lower | 50-1653 | Request it |
| – | Circuit board decal | 50-1930 | $59.11 CAD → |
| 42 | Control panel with decal | 50-1931 | $98.33 CAD → |
| 43 | Circuit board with thermostat switch, 115 V | 50-1929 | Request it |
| 44 | Ignitor assembly | 50-1656 | $140.00 CAD → |
| 45 | Auger motor, 3 rpm, 120 V | 50-1657 | Request it |
| 46 | Auger plate and bushing assembly | 50-1658 | $85.56 CAD → |
| 47 | Convection blower | 50-1659 | $250.00 CAD → |
| 48 | Combustion blower assembly | 50-1660 | Request it |
| 49 | Burn pot | 50-1661 | Request it |
| 50 | Burn pot liner | 50-1662 | $140.00 CAD → |
| 51 | 4" exhaust starter tube with flange, 5" long | 50-1914 | Request it |
| 52 | Combustion blower motor mounting gasket | 50-1664 | $59.53 CAD → |
| 53 | Hearth shield | 50-1665 | Request it |
| – | Circuit board wiring harness | 50-1666 | $126.17 CAD → |
Maxx-1 Heat Distribution Kit (HDK) (Enviro C-14699, p. 11)
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 3 | Lid gasket | EF-208 | $52.00 CAD → |
| 6 | Adjustable grill | 50-2887 | Request it |
| 7 | Grill | 50-2886 | Request it |
| 9 | Control sensor (175 °F) | 50-2888 | $63.84 CAD → |
| 10 | Fan sensor (120 °F) | EC-001 | $77.79 CAD → |
| 11 | High limit sensor (220 °F) | 50-2755 | Request it |
Enviro Maxx questions, answered from the manual
Where is the serial number on an Enviro Maxx pellet stove?
The rating label is on the inside of the hopper. The installer should also write the model and serial number on the installation data sheet at the back of the owner's manual. Keep it: Enviro asks for the unit serial number for warranty claims.
Source: Enviro C-15414, p. 3; C-15414, p. 36; C-15414, p. 35
Which Maxx manual do I need?
For a Maxx-1 sold since October 2020, use C-15414 R1. It is written for the homeowner, to be used with the separate technical manual. For an older stove, pick the archived Maxx-1 owner's manual whose dates cover your purchase date. If your stove has the optional Heat Distribution Kit (outlets for 4" heat ducts), its installation, wiring and parts are in C-14699.
Source: Enviro C-15414, p. 3; C-14699, p. 2; C-14699, p. 7
How do I start and shut down the Maxx?
Check the burn pot liner and the hopper, close both doors, then press ON/OFF on the control board. The start-up is automatic and takes about 10 to 15 minutes. To shut down in Manual or Hi/Low mode, press ON/OFF: the pellet feed stops and the blowers keep running until the stove has cooled. In Auto/Off mode, turn the thermostat down or off; the stove runs on low for 3 minutes before it shuts down. Don't unplug the stove while the combustion fan is running, as smoke may escape.
- Make sure the burn pot liner holes are clear and the liner is pushed up against the ignitor tube. (C-15414, p. 8)
- Check there are enough pellets in the hopper, and close the firebox door and the ash pan door. Never run the stove with either open. (C-15414, p. 8)
- Press the ON/OFF button. The system (mode) light flashes and the auger light flashes with each pulse of the auger. (C-15414, p. 9)
- On the very first start, or after the stove has run out of fuel, prime the auger: restart the stove five minutes into start-up, or put a small handful of pellets in the burn pot. (C-15414, p. 9)
- After about 10 to 15 minutes the system light turns solid and the convection blower comes on. You can then adjust the heat level. (C-15414, p. 9)
Source: Enviro C-15414, p. 8; C-15414, p. 9
What pellets can I burn in an Enviro Maxx?
Only 1/4" (6 mm) diameter wood pellets that are dry and free of dirt or impurities such as high salt content. The stove is approved for wood pellet fuel with up to 3% ash, and Enviro recommends pellets that meet or exceed the Pellet Fuel Industries (PFI) standards. Burning cordwood is prohibited, and so are garbage and flammable liquids. High-ash fuel may mean cleaning the stove daily. Store pellets at least 36" (1 m) from the stove.
Source: Enviro C-15414, p. 3; C-15414, p. 4
How do I clean the burn pot on a Maxx?
Check the burn pot liner daily and empty the burn pot and liner weekly. Any fuel can form clinkers (hard lumps of silica or impurities) that block the liner's air holes and hurt performance. A fire that keeps building up and overflowing the pot, or heavy clinkers, points to poor pellets or a stove that needs cleaning. The burn pot scraper tool is part 50-1254 and the burn pot liner is 50-1662.
- Wait until the stove is cold. (C-15414, p. 11)
- Open the firebox door with the handle on the right-hand side of the stove. (C-15414, p. 11)
- Lift the liner out of the burn pot. To remove the pot as well, lift its front gently and slide it off the air intake tube and the ignitor cartridge. (C-15414, p. 11)
- Scrape out whatever is clogging the liner's holes with a metal scraper, then dispose of the ashes from the liner and the pot. (C-15414, p. 11)
- Put the burn pot back, making sure the pipes are properly inserted into it. (C-15414, p. 11)
- Put the liner back with its ignitor hole lined up with the ignitor tube, and push the liner up against the ignitor tube. (C-15414, p. 11)
Source: Enviro C-15414, p. 3; C-15414, p. 11; C-15414, p. 30; C-15414, p. 31
How often does a Maxx need cleaning?
Daily: check the burn pot liner. Weekly: empty the burn pot and liner, clean the heat exchanger tubes (with the stove cold, lift the trivet and move the two scraper handles all the way up and down a few times), clean the door glass, check the ash pan and door gaskets, and empty the ash box. Twice a year or every two tons of pellets: the exhaust passages, the fresh air intake and the exhaust vent; Enviro recommends having your dealer clean the vent. Once a year: unplug the stove and vacuum the dust from both blowers (their bearings are sealed, so don't oil them). At the end of the season, clean the stove and unplug it.
Source: Enviro C-15414, p. 11; C-15414, p. 12; C-15414, p. 13
What do the flashing lights on the Maxx control board mean?
A flashing #3 light on the heat output bar means the exhaust temperature switch has opened: no fire is detected or the fire has gone out, for example because the hopper is out of pellets. Strong negative pressure in the room can also cause it; if opening a window helps, the manual calls for a fresh air intake to the stove or room. A flashing #2 light means the vacuum switch has stopped the auger because the venting may be blocked. A flashing #4 light means the 200 °F (93 °C) high limit switch on the hopper has tripped; your dealer has to reset it and find out why the stove overheated. Press ON/OFF to reset the board after a trouble code. Enviro says troubleshooting should be done by qualified technicians or installers.
Source: Enviro C-15414, p. 8; C-15414, p. 26; C-15414, p. 27
Why does my Maxx keep going out, or not light?
Look at what is left in the burn pot liner. Fresh unburned pellets or cigarette-like ash mean the fire went out before the stove shut off: check the slider damper position and turn the heat level up slightly, since poor pellets need higher settings. Partly burned pellets mean the stove shut down for lack of air, low exhaust temperature or a power cut: the damper may need adjusting or the stove a more complete cleaning. If the pellets won't light at all, make sure the liner sits tight and square against the ignitor tube; the ignitor should glow bright orange. If the exhaust blower isn't running, call your dealer. The slider damper is set at installation by a qualified technician with a pressure gauge.
Source: Enviro C-15414, p. 28; C-15414, p. 10; C-15414, p. 25
How do I clean the glass on a Maxx?
Clean it weekly, and only when the stove is cold, never while it is running or the glass is hot. The glass is ceramic. If it breaks, don't run the stove; Enviro recommends having your dealer replace it, and the replacement must be the Enviro glass (9" x 13", part EF-061).
- Let the stove cool completely. (C-15414, p. 12)
- Open the door by lifting the handle. (C-15414, p. 12)
- Wipe the outside and inside of the glass with a dry soft cloth. (C-15414, p. 12)
- If build-up remains, use a paper towel and a gas appliance glass cleaner, or a damp paper towel dipped in fly ash, which is a very mild abrasive. (C-15414, p. 12)
- Finish by wiping both sides of the glass with the dry soft cloth. (C-15414, p. 12)
Source: Enviro C-15414, p. 12; C-15414, p. 5; C-15414, p. 13
Can I run the Maxx from a wall thermostat?
Yes. A switch on the control board selects Manual, Hi/Low or Auto/Off. Manual is run from the board alone. In Hi/Low the stove drops to the low setting when the thermostat is satisfied and returns to your heat level when it calls again. In Auto/Off the stove lights itself when the thermostat calls for heat; when it is satisfied the stove runs on low, and if the thermostat has not called again within 30 minutes the stove shuts down, then relights on the next call. The manual specifies a 12 or 24 V thermostat wired with 18 x 2 gauge wire. If the room needs too little heat in Hi/Low, the stove can trip its high limit switch, which then needs a manual reset.
Source: Enviro C-15414, p. 8; C-15414, p. 9; C-15414, p. 15
Enviro Maxx parts from the manual, sold here

Enviro Ceramic Fan Sensor (EC-001)
Sale price $77.79 CAD Regular price $85.99 CAD

Enviro Fireplaces Power Cord Replacement - (EC-043)
Sale price $76.90 CAD Regular price $84.99 CAD

Enviro Pellet Stoves High Temperature Sensor (EF-016)
Sale price $79.80 CAD Regular price $87.99 CAD

Enviro Silicone Hose - Red - Meridian / EF2 / EF3 .... (EF-018)
Sale price $38.00 CAD Regular price $41.99 CAD

Enviro Slider Damper Rod (EF-050)
Sale price $71.62 CAD Regular price $78.99 CAD

Enviro EF2 & Max Pellet Stove High Temperature Glass with Gasket (EF-061)
Sale price $172.20 CAD Regular price $189.99 CAD

Enviro Air Wash Control Knob - 1" (EF-068)
Sale price $68.10 CAD Regular price $74.99 CAD

Enviro Shoulder Bolt & Roll Nut - Set of 2 (many models) (EF-124)
Sale price $69.64 CAD Regular price $76.99 CAD