Manuals & parts · Direct vent gas fireplace insert
Quick answer
The current Enviro EX35 manual is C-16996, the EX35 Owner's Manual [2024], a free PDF from enviro.com for the EX35 IPI gas fireplace insert, listed from February 2024. Inserts from February 2018 to January 2024 are covered by three archived revisions of C-15091, which also describe a top light that the 2024 manual drops. The rating label is on the left side of the unit.
Owner's manuals for the Enviro EX35 gas fireplace insert since 2018, the factory parts lists with part numbers, key specs, and answers to common EX35 questions, each taken from the official Enviro manual with the page number.
Last updated · From Enviro docs C-16996 rev [2024] and C-15091 rev [2021] R1 · Answers drafted from the manuals; staff review pending
EX35 (2024 manual)
IPI gas fireplace insert with a 9-piece log set, front ember lights and an adjustable exhaust restrictor, run by the Proflame 2 remote and integrated fireplace controller (IFC). The remote's AUX function is not used on this version.
Manuals: C-16996
EX35 with top light (2018 to 2024)
Earlier inserts, covered by the archived C-15091 manual and its 2021 revisions. Besides the front ember lights they have a top light behind the baffle at the top of the firebox, switched on and off with the remote's AUX key, with its own assembly and G9 halogen bulb in the parts list. Use the revision whose dates match your installation.
Manuals: C-15091
Find your model and serial number: The rating label is located on the left side of the unit. (Enviro C-16996, p. 6)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
EX35 Owner's Manual [2024]
C-16996 rev [2024] · Feb 1, 2024 – Present · 44 pages · Current
Can't open a link? Enviro lists every version on its manuals pages: Enviro EX35 manuals.
From the parts lists in the Enviro EX35 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Door release tool | 50-2510 | $60.00 CAD → |
| 2 | Flue adapter tool | 50-3505 | Request it |
| 3 | EX35 flue adaptor | 50-3506 | Request it |
| 4 | EX35 flue adaptor gasket | 50-3507 | Request it |
| 5 | EX35 door spring latches (set of 2) | 50-3508 | Request it |
| 6 | EX35 log tray assembly | 50-3509 | Request it |
| 7 | EX35 burner pan | 50-3510 | $331.10 CAD → |
| 8 | EX35 light tray cover | 50-3511 | Request it |
| 9 | EX32 / EX35 light tray assembly | 50-3512 | $202.94 CAD → |
| – | Halogen socket with wires | 50-2028 | Request it |
| 10 | EX35 door complete | 50-3513 | Request it |
| 11 | Glass with gasket (28.5" x 18") | 50-2523 | $372.31 CAD → |
| – | Dual bulb door gasket (10 ft) | 50-634 | $68.00 CAD → |
| 12 | Safety screen | 50-3073 | $222.00 CAD → |
| 13 | Log set (9 pcs)option | 50-3502 | $635.56 CAD → |
| 14 | Brick liner setoption | 50-2525 | $411.27 CAD → |
| – | Ledgestone liner setoption | 50-3486 | $398.18 CAD → |
| – | Porcelain liner setoption | 50-2437 | $510.55 CAD → |
| 15 | EX32 / EX35 pilot shield | 50-3514 | Request it |
| 16 | EX35 stainless steel baffle | 50-3515 | Request it |
| 17 | Fan only | 50-2493 | $243.33 CAD → |
| 18 | Proflame 2 IFC | 50-3791 | $342.06 CAD → |
| – | Proflame 2 IFC wire harness (0.584.924) | 50-3030 | Request it |
| 19 | Battery holder, 4 x AA | 50-3027 | $41.82 CAD → |
| 20 | Proflame 2 transmitter (0.584.045) | 50-3028 | $186.54 CAD → |
| 21 | 885 Proflame IPI valve, natural gas | 50-2682 | $270.00 CAD → |
| 22 | PSE IPI pilot assembly (2021) | 50-4058 | $120.00 CAD → |
| – | IPI LP pilot orifice (2021) | 50-4080 | $22.00 CAD → |
| 23 | 2 A glass fuse | 50-2075 | $36.32 CAD → |
| 24 | Replacement halogen bulb | 50-3291 | $15.00 CAD → |
| 25 | Ceramic wire nut (set of 2) | 50-3517 | Request it |
| 26 | Reset button | 50-3518 | Request it |
| 27 | Proflame 2 transmitter (0.584.040) | 50-3265 | $185.45 CAD → |
| – | Power cord (115 V) | EC-042 | $55.38 CAD → |
| – | Strain relief | EC-044 | $73.29 CAD → |
| – | NG to LP stepper motor only | 50-3753 | $187.20 CAD → |
| – | LP to NG stepper motor only | 50-3870 | $115.00 CAD → |
| – | Ceramic wool embers only | 50-893 | Request it |
| – | 12 oz. can of metallic black touch-up paint | PAINT-12-MB | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 17 | Top light assembly | 50-3516 | $92.44 CAD → |
| – | Top light bulb only | 50-4119 | $18.27 CAD → |
On the left side of the unit. Have the installer record the model and serial number on the installation data sheet at the back of the manual. Enviro asks for the unit serial number on warranty claims.
Source: Enviro C-16996, p. 6; C-16996, p. 43; C-16996, p. 44
For an EX35 insert from February 2024 on, use C-16996, the EX35 IPI gas fireplace insert owner's manual. Earlier EX35 inserts are covered by the archived C-15091 manual: the original edition from February 2018, a 2021 revision, and a 2021 R1 revision used until January 2024. Those editions also cover the top light at the top of the firebox, which the 2024 manual no longer lists. Match your installation date to the dates in the documents list.
Source: Enviro C-16996, p. 1; C-16996, p. 14; C-15091, p. 14; C-15091, p. 19
The EX35 has fully automatic ignition. Don't try to light the pilot by hand. Press ON/OFF on the Proflame 2 remote; the pilot lights, then the main burner, in about 10 seconds. The control tries to light the pilot several times if it needs to and stops if it can't. If the insert won't operate, follow the instructions to turn off the gas and call your service technician or gas supplier.
Source: Enviro C-16996, p. 8; C-16996, p. 12
Check the simple causes first. The remote may be too far from the insert, or its batteries may be dead or low. A battery icon on the remote display means its three AAA batteries are low. If the controller doesn't beep when you press ON/OFF, its four AA backup batteries are low. After changing batteries, re-sync the remote to the controller with the reset button.
Source: Enviro C-16996, p. 39; C-16996, p. 15; C-16996, p. 12
The LED on the Proflame 2 controller (IFC) blinks a code. One blink means a low battery condition (below 4 V). Two blinks mean a parasitic pilot flame. Three blinks mean the system is locked out, for example after a failed ignition. The controller tries twice to light, each try lasting about 60 seconds, with about 35 seconds between them. Remove whatever caused the lockout, then reset the board. If the pilot still won't light or stay lit, call a qualified service person: the manual says repair should be done by a qualified service person.
Source: Enviro C-16996, p. 38; C-16996, p. 39; C-16996, p. 40; C-16996, p. 3
The pilot turns itself off after 7 days without any main burner use; relight the pilot to reset the counter. Enviro recommends continuous pilot (CPI) mode in winter when it is below 50°F (10°C) outside: it keeps the chimney warm so it drafts at ignition and cuts condensation on the glass. To switch modes, turn the insert off, press MODE on the remote until the CPI icon shows, then press the up arrow for continuous pilot or the down arrow to go back to intermittent pilot (IPI). A wrong exhaust restrictor setting for the vent length can also stop the pilot staying lit; that is an installer check.
Source: Enviro C-16996, p. 15; C-16996, p. 39; C-16996, p. 25
Yes. The battery holder lets the fireplace run during a power outage, and you can still turn the flame up and down, but the fan and lights stay off until power is back, to save the batteries. The controller takes four AA batteries; it gives no beep when they are low.
Source: Enviro C-16996, p. 12; C-16996, p. 11; C-16996, p. 15
The front ember light assembly has 5 halogen bulbs, dimmed from the remote through six levels. A spare bulb comes with the fireplace, and the replacement halogen bulb is part 50-3291. Work only when the insert is off and completely cool. On older EX35s with a top light, its bulb sits behind the baffle and Enviro says to contact your dealer for service.
Source: Enviro C-16996, p. 19; C-16996, p. 14; C-16996, p. 41; C-15091, p. 19
Condensation on a cold start is normal and clears as the glass warms. Additives in the gas can also leave a haze, and the first paint cure leaves a film. Clean the glass once it has cooled after the first burn, again about two weeks later, then no more than two or three times a season, depending on use.
Source: Enviro C-16996, p. 17; C-16996, p. 40
Stop using the insert. Don't run it with the glass cracked, broken or removed. The glass is a high-temperature ceramic and needs a factory replacement bought from an Enviro dealer. Removing and replacing the glass in the door must be done by a licensed or qualified service person. The parts list gives 50-2523 for the glass with gasket (28.5" x 18") and 50-3513 for the complete door.
Source: Enviro C-16996, p. 17; C-16996, p. 41
Only with a certified conversion kit, installed by a qualified service agency. The kit for EX35 models contains a burner orifice (#34 for natural gas, #51 for propane), a pilot orifice (0.2 for natural gas, 0.14 for propane), a servo regulator with diaphragm, an instruction sheet and two conversion labels. The installer changes the pilot orifice, the burner orifice and the valve's servo regulator, leak-tests the gas connections, checks the inlet and manifold pressures and puts a conversion label on or near the rating label. The parts list also gives the stepper motors 50-3753 (NG to LP) and 50-3870 (LP to NG).
Source: Enviro C-16996, p. 2; C-16996, p. 20; C-16996, p. 21; C-16996, p. 41
Sale price $372.31 CAD Regular price $409.99 CAD