Enviro Parts Only / One brand, every part
Search by Model / Find your exact unit
14-Day Returns / See our returns policy
Expert Advice / From people who care
Enviro Fireplace PartsEvery Enviro part, the right fit.
SupportWe're here to helpTrack OrderCheck status
Find My PartFind the right fit
  • Models
  • Find My Part
  • Manuals
  • Contact
Menu
  • Models
  • Find My Part
  • Manuals
  • Contact
Enviro Fireplace PartsEvery Enviro part, the right fit.
Find My Part Request a Part
Enviro Fireplace Parts

Every Enviro part, the right fit.

Get fitment tips, restock alerts, and Enviro parts news — straight to your inbox.

Shop

  • Shop by Model
  • Shop by Category
  • All Parts

Parts by Appliance

  • Wood Stove Parts
  • Gas Fireplace Parts
  • Pellet Stove Parts

Help & Support

  • Find My Part
  • Request a Part
  • Help Centre
  • Shipping & Delivery
  • Returns & Refunds
  • Warranty

Company

  • About Us
  • Contact Us
  • Blog

© 2026 Enviro Fireplace Parts. All rights reserved.

Enviro Fireplace Parts is operated by Friendly Fires Inc. · (705) 741-1900

PrivacyTermsAccessibility
  • Home
  • Models
  • Parts
  • Support
  • Cart
  1. Home
  2. Manuals
  3. Enviro DV48

Manuals & parts · Direct vent gas fireplace (discontinued)

Enviro DV48 Manuals

Quick answer

The Enviro DV48 is a discontinued direct vent gas fireplace sold under the Westgate name, and Enviro lists all of its manuals as archived. The last editions are owner's manual C-13875 and technical manual C-13874 (installation, troubleshooting and the parts list), listed to December 2014 and free PDFs from enviro.com. DV48 parts are still sold here; the rating label is on a chained plate under the firebox, below the door frame.

Every DV48 owner's and technical manual Enviro still publishes, the factory parts list with part numbers (door and glass, burners, logs and glass media, firebox panels, Proflame remote and ignition parts, faces and kits), key specs, and answers to common DV48 questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the DV48, but we still sell its parts.

Last updated Nov 25, 2026 · From Enviro docs C-13875, C-13874 and C-11799 · Answers drafted from the manuals; staff review pending

Shop Enviro DV48 partsGet the manual

Which Enviro DV48 do I have?

DV48 with log set / ember bed burner

Log burner with a cast grate, ceramic burner accents and a multi-piece log set. Like every DV48 it lights itself (intermittent pilot ignition) and runs from the Proflame GTMF remote, with six flame levels, a split valve that turns the rear burner off, a fan control module and two halogen accent lights.

Manuals: C-13875, C-13874, C-12004, C-12029, C-11799

DV48 with glass media burner

Glass burner with a glass tray filled with the supplied black and white crushed glass, a burner trim and optional rock accents. Same controls, venting and manuals as the log set version.

Manuals: C-13875, C-13874, C-12004, C-12029, C-11799

DV48, serial numbers 215256 to 216700

Enviro lists a separate owner's manual for this serial number range (May to August 2009). It is one 60-page book with the installation, operation and parts list together; later units have a separate owner's manual and technical manual.

Manuals: C-11799

Find your model and serial number: The rating and lighting instruction label is below the door frame, underneath the firebox, attached to a chain. Slide the plate forward out from under the firebox to read it, and always return it when finished. (Enviro C-13875, p. 5)

Diagram of an Enviro DV48 showing where the rating label with the model and serial number is: On the Enviro DV48 the rating label is on a chained plate under the firebox, below the door frame: slide it forward to read it.

Enviro DV48 parts from the manual, sold here

Enviro Door Tool (DV48/DV62/Q4) (50-2001) — Enviro Fireplace Parts

Enviro Gas Fireplace Door Removal Tool -DV48 / DV62 / Q4 Models (50-2001 / 502001)

Sale price $74.00 CAD Regular price $81.99 CAD

Enviro DV48/Q4 Natural Gas Valve Assembly (50-2004) — Enviro Fireplace Parts

Enviro DV48/Q4 Natural Gas Valve Assembly (50-2004)

Sale price $711.34 CAD Regular price $782.99 CAD

Enviro Digital Fireplace Controller SP1 (50-278150-2005)

Enviro Digital Fireplace Controller SP1 (50-278150-2005)

Sale price $189.00 CAD Regular price $207.99 CAD

Where to find the Enviro DV48 rating label. Our diagram, based on Enviro C-13875 p. 5.
Chart of Enviro DV48 versions: DV48 with log set / ember bed burner, DV48 with glass media burner, DV48, serial numbers 215256 to 216700, with what sets each one apart.
Enviro DV48 versions at a glance. Our chart, from the Enviro manuals listed below.

Enviro DV48 owner's and installation manuals

Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.

The Enviro DV48 is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro DV48 parts.

Archived Enviro DV48 manuals (5)
  • DV48 Technical Manual

    C-13874 · Apr 3, 2012 – Dec 01, 2014

    PDF
  • DV48 Owner's Manual

    C-13875 · Feb 15, 2012 – Dec 01, 2014

    PDF
  • DV48 Technical Manual

    C-12029 · Dec 4, 2009 – Apr 03, 2012

    PDF
  • DV48 Owner's Manual

    C-12004 · Aug 13, 2009 – Feb 15, 2012

    PDF
  • SN 215256 - 216700 DV48 Owner's Manual

    C-11799 · May 12, 2009 – Aug 13, 2009

    PDF

Can't open a link? Enviro lists every version on its manuals pages: Enviro DV48 manuals, Enviro legacy manuals.

Enviro DV48 parts list, with part numbers

From the parts lists in the Enviro DV48 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.

DV48 parts (Enviro C-13874, p. 49)

RefPartPart #Our store
1Glass door assembly50-2002Request it
2Door tool50-2001$74.00 CAD →
3Panel set, porcelainoption50-1957Request it
4Panel set, Octoberoption50-1944Request it
5Panel set, Sandstoneoption50-1945Request it
6Panel set, Ledgestoneoption50-1946Request it
7Burner, glass media50-1938Request it
8Burner, log / ember bed50-1975Request it
9Log setoption50-1977Request it
10Crushed glass, whiteoption50-1980Request it
11Crushed glass, blackoption50-1981Request it
12Refractory burner trim, black50-1978Request it
13Valve assembly50-2004$711.34 CAD →
14Fan controller module50-1572Request it
15IPI burner controller50-2005$189.00 CAD →
16Remote receiver50-2007Request it
17Transmitter50-2006Request it
18Wire harness, receiver50-2008Request it
19Wire harness, IPI50-2009$97.57 CAD →
20Pilot assembly50-2010$106.80 CAD →
21Burner accent kit, Octoberoption50-1941Request it
21Burner accent kit, Sandstoneoption50-1943Request it
21Burner accent kit, Ledgestoneoption50-1942Request it
22Vent restrictor set50-2011Request it
23Fireplace facing kit50-2012Request it
24Rock accentsoption50-1939Request it
25Glass burner accent, Ledgestoneoption50-1973Request it
26Glass burner accent, Sandstoneoption50-1958Request it
27Westgate heat distribution kitoption50-1935Request it
28Power vent kitoption50-1970Request it
29Cast grate50-1976Request it
30Door trim kit with screen, blackoption50-1947Request it
31Arched Ovation, antique copperoption50-1948Request it
31Arched Ovation, natural ironoption50-1949Request it
31Arched Ovation, blackoption50-1950Request it
32Square Ovation, antique copperoption50-1951Request it
32Square Ovation, natural ironoption50-1952Request it
32Square Ovation, blackoption50-1953Request it
33Gate House face, blackoption50-1954Request it
34Town House face, blackoption50-1955Request it
35Carriage House face, blackoption50-1956Request it
36LPG conversion kit50-1936Request it
36NG conversion kit50-2030Request it
36Pilot orifice (injector), natural gas, threadedEC-019$61.62 CAD →
36Pilot orifice (injector), propane, threadedEC-020$72.00 CAD →
–Log burner kitoption50-1940Request it
–Firebox liner set, herringboneoption50-2013Request it
–Log burner accent set, herringboneoption50-2014Request it
–S.I.T. pilot 1/8" tube with end ferrules (1 piece)30-043$59.75 CAD →
–Light bulbs (set of 2)50-1982Request it
–Pilot flame sensor (long ceramic)50-1983Request it
–Pilot bypass switch50-1984Request it
–Valve access panel gasket50-1985Request it
–Owner's manual50-2003Request it
–Technical manual50-2163Request it
–Light circuit wire harness50-2028Request it
–Main orifice tray gasket50-2029Request it
–Fan control module with Velcro strap50-2031Request it
–Light bulb cover (specify colour)50-2032Request it
–Dual bulb door gasket (10 ft)50-634$68.00 CAD →
–Halogen cycle (pin socket)20-034Request it

Enviro DV48 questions, answered from the manual

Where is the rating label on an Enviro DV48?

Under the firebox, below the door frame. The rating and lighting instruction label is on a plate attached to a chain: slide the plate forward out from under the firebox to read it, and always slide it back when you are done. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.

Source: Enviro C-13875, p. 5; C-13875, p. 28

Which DV48 manual do I need?

The DV48 is discontinued and Enviro lists every DV48 manual as archived. The DV48 has two books: the owner's manual (operation, remote control and care) and the technical manual (installation, gas conversion, flash codes, troubleshooting and the parts list). The last editions are owner's manual C-13875 and technical manual C-13874, both listed to December 2014; C-12004 and C-12029 are the earlier pair. Fireplaces with serial numbers 215256 to 216700 have their own owner's manual, C-11799, which holds everything in one book.

Source: Enviro C-13875, p. 3; C-13874, p. 3; C-13874, p. 49; C-11799, p. 3

How do I turn on a DV48?

With the remote. The DV48 has an ignition device that lights the pilot automatically: do not try to light the pilot by hand. The control tries to light the pilot several times if necessary; if it can't, it stops trying. In that case turn the fireplace off and call your service technician or gas supplier.

  1. Read the safety information on the lighting label. If you smell gas, stop and follow the gas-smell instructions on the label. (C-13875, p. 25)
  2. Check that the receiver's three-position slider switch is in the Remote position. (C-13875, p. 20)
  3. Press the ON/OFF key on the remote, or set the remote's thermostat. The receiver beeps once to confirm the command. (C-13875, p. 25)
  4. The system lights the pilot, then the main burner; this takes about 10 seconds. (C-13875, p. 20)
  5. To turn it off, press the ON/OFF key again (or set the thermostat to its lowest setting). The receiver beeps to confirm. (C-13875, p. 25)

Source: Enviro C-13875, p. 25; C-13875, p. 20

My DV48 remote stopped working. How do I re-sync it?

Check the batteries first. A battery icon on the remote's display means its three AAA batteries are low. If the receiver doesn't beep when you press ON/OFF, its four AA batteries are low. Turn off the main gas supply to the fireplace before you remove or reinsert the receiver batteries. If the remote and receiver have lost communication, program the remote to the receiver again. The replacement transmitter is part 50-2006 and the receiver 50-2007.

  1. Turn off the main gas supply to the fireplace, then put four fresh AA batteries in the receiver, matching the polarity marks. (C-13875, p. 18)
  2. Set the receiver's three-position slider switch to Remote. (C-13875, p. 20)
  3. Push the end of a paper clip into the hole marked PRG on the receiver's front cover. The receiver beeps three times when it is ready to pair. (C-13875, p. 20)
  4. With three AAA batteries in the remote, press its ON button. The receiver beeps four times to show it has accepted the remote's code, and the system is initialized. (C-13875, p. 20)

Source: Enviro C-13875, p. 22; C-13875, p. 18; C-13875, p. 20; C-13874, p. 44; C-13874, p. 49

Does the DV48 work in a power outage?

The fan control module normally powers the receiver, and the receiver's four AA batteries take over only when line power is interrupted or lost, so keep fresh batteries in it. If the receiver or remote batteries are low or dead, you can bypass the remote: slide the receiver's three-position switch to ON and the main burner comes on. Keep away from the burner when you do this, as the fireplace can turn on suddenly.

Source: Enviro C-13875, p. 19; C-13875, p. 22; C-13874, p. 15

What do the blinking lights on the DV48 control board mean?

The Proflame DFC ignition board has an LED that flashes a code. One blink at intervals means a low battery (under 4V). Two blinks mean a parasitic pilot flame. Three blinks mean the system is locked out, for example after a failed ignition: the board tries to light twice, each try lasting about 60 seconds with about 35 seconds between them, then locks out until it is reset. To reset, turn the system off with the remote's ON/OFF button and press it again after about 2 seconds, or move the receiver's slider switch to OFF, wait about 2 seconds and move it back to ON. Clear anything that could stop ignition first; if it keeps locking out, call a qualified service technician.

Source: Enviro C-13874, p. 43; C-13874, p. 44; C-13874, p. 45

What does the split valve (double flame icon) on the DV48 remote do?

It turns the rear section of the burner on or off. With the rear burner off, the fireplace still shows a flame but gives off much less heat, and the front flame setting is not affected. Press the bottom key on the remote repeatedly until the double flame icon lights up, then use the up or down key to switch the rear burner on or off. Turning it off may make an extinguishing pop, especially on propane.

Source: Enviro C-13875, p. 22

How do I replace the accent light bulbs in a DV48?

The DV48 has two halogen accent lights at the back of the firebox, switched with the AUX function on the remote. The bulb is a halogen 120V 50W GY6.36 (a lower wattage can be used), sold at most hardware or lighting stores; the parts list also has a set of two, 50-1982. Let the fireplace cool to room temperature first.

  1. Let the fireplace cool completely to room temperature. (C-13875, p. 26)
  2. Remove the fireplace door, the logs, the burners and the firebox liners. (C-13875, p. 26)
  3. Lift the light cover on the back wall of the firebox about ½" and pull it towards you. (C-13875, p. 26)
  4. Lift the old bulb out of its socket and fit the new one, holding it with paper or its wrapper: oils from your skin shorten its life. (C-13875, p. 26)
  5. Refit the light covers before reassembling the liners, burners, logs and door. Don't run the fireplace without the light covers. (C-13875, p. 26)

Source: Enviro C-13875, p. 26; C-13875, p. 21; C-13874, p. 49

How do I take the DV48 door off to clean the glass?

Condensation on a cold start is normal, and the first paint cure can leave a film, so clean the glass about two weeks after installation, then no more than two or three times a season depending on use. Never clean the glass while it is hot; hot glass will cause burns.

  1. Let the fireplace cool. If an optional front is fitted, lift it off its four corner hooks. (C-13875, p. 16)
  2. Slide the door latch tool under the door frame, catch each lower door latch, pull it out slightly and then down until it clears the tab on the door frame. (C-13875, p. 7)
  3. Pull the bottom of the door frame forward about 2" (5cm), then lift it up off the two upper door hooks and away, keeping the glass secure in the frame. (C-13875, p. 7)
  4. Check that the gasket on the back of the glass is attached and intact, then clean the glass with a mild glass cleaner and a soft cloth. Abrasive cleaners damage the glass and plated surfaces. (C-13875, p. 26)
  5. Refit the door by reversing these steps. Never run the fireplace with the glass removed. (C-13875, p. 7)

Source: Enviro C-13875, p. 26; C-13875, p. 7; C-13875, p. 16; C-13874, p. 2

The DV48 glass is cracked. What do I need?

Stop using the fireplace: do not operate it with the glass front removed, cracked or broken. The glass is a high temperature ceramic and needs a factory replacement from an authorized Westgate dealer, part 50-2002 (glass door assembly); no substitute materials are allowed. Removing and replacing the glass must be done by a licensed or qualified service person, and you should wear gloves when handling a damaged door. The dual bulb door gasket is 50-634.

Source: Enviro C-13875, p. 26; C-13874, p. 49

Can I convert a DV48 from natural gas to propane?

Only with the manufacturer's conversion kit, installed by a qualified service agency. The propane kit holds a pilot orifice, left and right orifices for the glass tray burner and for the log burner, a regulator diaphragm, a servo regulator and a conversion label. The installer changes the pilot orifice and the two main orifices at the back of the firebox floor, swaps the regulator diaphragm and fits the propane servo regulator on the valve, then checks the gas pressures: propane inlet pressure should be at least 12" WC. The parts list gives 50-1936 for the LPG conversion kit and 50-2030 for the NG kit.

Source: Enviro C-13874, p. 29; C-13874, p. 30; C-13874, p. 49

What maintenance does a DV48 need?

Plan on an annual service by a qualified service person: cleaning, battery replacement, light replacement, a venting inspection and an inspection of the burner, log set and firebox liners. With the door, logs, burner trim and burners out, vacuum dust, lint and debris from the firebox floor with a soft brush attachment, brush dirt off the burner top and carbon off the logs, and clean both sides of the glass. If any part of the vent or air intake system is ever taken apart, a qualified hearth technician must reassemble and reseal it.

Source: Enviro C-13875, p. 26; C-13875, p. 25; C-13875, p. 2

Key specs

Gas input, natural gas
16,000 to 48,000 BTU (C-13875, p. 6)
Gas input, propane
17,000 to 48,000 BTU (C-13875, p. 6)
Manifold pressure
Natural gas 3.5 / 1.6 in. WC; propane 10 / 6.4 in. WC (as printed on the rating label) (C-13875, p. 6)
Minimum supply pressure
Natural gas 5 in. WC, propane 12 in. WC (C-13875, p. 6)
Gas connection
½" SAE 45° male flare fitting on a ⅜" MPT gas line (C-13874, p. 28)
Venting
5" x 8" direct vent: AmeriVent Direct, Secure Vent, Direct-Temp, Direct Vent GS or EXCELDirect ICC (C-13874, p. 19)
Electrical
120 V AC, 60 Hz, less than 7 amperes (C-13875, p. 6)
Remote system
Proflame GTMF: transmitter on three AAA batteries, receiver on four AA batteries, fan control module on 120 V (C-13875, p. 18)
Accent lights
Two halogen bulbs, 120V 50W GY6.36 (lower wattages may be used) (C-13875, p. 26)
Certified altitude
0 to 4500 ft (1372 m) (C-13875, p. 4)

Need a part for your Enviro DV48?

9 of 61 parts-list items are sold here.

Shop Enviro DV48 partsNot sure which part? Find my part

Gas work, venting, electrical and glass replacement must be done by a qualified installer or service agency. These answers summarize Enviro's manuals; the manual for your exact model and serial number is the authority.

Enviro 50-2785 50-2009 Wiring Harness — Enviro Fireplace Parts

Enviro Wiring Harness (50-2009)

Sale price $97.57 CAD Regular price $107.99 CAD

Enviro Q4 SIT IPI Pilot Assembly - Round Hood with Flame Sensor (50-2010) - photo 1 — Enviro Fireplace Parts

Enviro Q4 SIT IPI Pilot Assembly - Round Hood with Flame Sensor (50-2010)

Sale price $106.80 CAD Regular price $117.99 CAD

Enviro Pilot Orifice (Injector) - Natural Gas, Threaded (Post Oct 2000) (EC-019) — Enviro Fireplace Parts

Enviro Pilot Orifice (Injector) - Natural Gas, Threaded (Post Oct 2000) (EC-019)

Sale price $61.62 CAD Regular price $67.99 CAD

Enviro Threaded Pilot Injector - LP (EC-020) — Enviro Fireplace Parts

Enviro Threaded Pilot Injector - LP (EC-020)

Sale price $72.00 CAD Regular price $79.99 CAD

Enviro 30-043 Pilot Tube — Enviro Fireplace Parts

Enviro Pilot Tube with Ferules (30-043)

Sale price $59.75 CAD Regular price $65.99 CAD

See all Enviro DV48 parts →
, and 6 parts are tagged to fit the Enviro DV48