Manuals & parts · Direct vent freestanding gas stove (discontinued)
Quick answer
The Enviro Bedford is a discontinued direct vent freestanding gas stove, and Enviro lists both of its manuals as archived. They are the combined Westport & Bedford owner's manuals, C-10238 and C-10168 from 2003, free PDFs from enviro.com. Bedford parts are still sold here, and the manual's parts diagram shows the rating plate at the back of the stove.
Both Bedford owner's manuals Enviro still publishes (combined Westport & Bedford editions), the factory parts list with part numbers (valve, pilot, burner, log set, glass, blowers, and the Bedford top, posts, sides and Arch or Gothic filigree doors), key specs and answers to common owner questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the Bedford, but we still sell its parts.
Last updated · From Enviro docs C-10238 and C-10168 · Answers drafted from the manuals; staff review pending
Bedford, top vent
Ships as a 30,000 Btu top-vented freestanding stove (natural gas; 26,500 Btu on propane) for vertical or horizontal terminations, with a built-in vent restrictor plate set from the vent-length chart. S.I.T. Nova millivolt valve with battery electronic pilot ignition.
Manuals: C-10238, C-10168
Bedford, rear vent 20,000 Btu
Rear vented straight out a flat wall with no more than 10 inches of vent pipe, using the rear vent main burner orifice and the restrictor left open. Not for corner installations.
Manuals: C-10238, C-10168
Bedford, rear vent 30,000 Btu
Rear vented at the full 30,000 Btu rating; it must be vented with a 36 inch snorkel kit. Not for corner installations.
Manuals: C-10238, C-10168
Find your model and serial number: The manual does not say in words where the rating label is. Its body parts diagram shows the rating plate (label), part 30-049, at the back of the stove beside the rear shield. (Enviro C-10238, p. 32)

Sale price $128.32 CAD Regular price $144.99 CAD

Sale price $75.96 CAD Regular price $83.99 CAD

Sale price $69.09 CAD Regular price $76.99 CAD
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro Bedford is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro Bedford parts.
Can't open a link? Enviro lists every version on its manuals pages: Enviro Bedford manuals, Enviro legacy manuals.
From the parts lists in the Enviro Bedford manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| – | Conversion kit, LP to NG (top vent)option | 30-001 | $128.32 CAD → |
| – | Conversion kit, NG to LP (top vent)option | 30-002 | Request it |
| – | Conversion kit, LP to NG (rear vent)option | 30-005 | Request it |
| – | Conversion kit, NG to LP (rear vent)option | 30-006 | Request it |
| – | Levelling bolts | 30-013 | Request it |
| – | Owner's manual | 30-019 | Request it |
| – | Door knob clip | 30-029 | $75.96 CAD → |
| – | Door latch assembly, nickel | 30-033 | Request it |
| – | Valve mounting bracket | 30-047 | Request it |
| – | Rear shield | 30-048 | Request it |
| – | Rating plate (label) | 30-049 | Request it |
| – | Gas valve cover | 30-050 | $69.09 CAD → |
| – | Flue connection | 30-051 | Request it |
| – | Inner door handles (2 per set) | 30-052 | Request it |
| – | Venturi adjustment rod | 30-053 | Request it |
| – | Firebox | 30-054 | Request it |
| – | Burner | 30-055 | $307.69 CAD → |
| – | 45° elbow and gasket | 50-040 | $176.73 CAD → |
| – | Fan kit, 180 CFMoption | 50-173 | Request it |
| – | Left rear log (B) | 50-296 | Request it |
| – | Left front log (A) | 50-297 | Request it |
| – | Right log (C) | 50-298 | Request it |
| – | Electronic ignition module switch | 50-329 | $84.44 CAD → |
| – | Blank orifice #73, all gas models | 50-343 | $35.47 CAD → |
| – | Wiring harness | 50-348 | Request it |
| – | Pressure relief door with gasket, rod and brackets | 50-366 | Request it |
| – | Control panel decal | 50-461 | Request it |
| – | Inner door complete (with glass and handles) | 50-463 | $1,085.16 CAD → |
| – | Embers (post 2000) | 50-491 | Request it |
| – | 4" flex coupler | 50-497 | Request it |
| – | Dual convection blower, 115V (no mount) | 50-512 | $353.33 CAD → |
| – | Firebox baffle | 50-533 | Request it |
| – | Valve extension rod with knob (1 per set) | 50-555 | $79.04 CAD → |
| – | Electronic ignition module | 50-589 | $57.78 CAD → |
| – | Control panel | 50-690 | Request it |
| – | Drafthood adapter | 50-841 | Request it |
| – | 120° ceramic fan temperature sensor (all models) | EC-001 | $77.79 CAD → |
| – | S.I.T. Nova valve, NG (50% turn down) | EC-006 | Request it |
| – | S.I.T. Nova valve, LP (50% turn down) | EC-007 | Request it |
| – | Thermocouple (post 10/00) | EC-009 | Request it |
| – | Spark electrode with ignitor cable (post 10/00) | EC-011 | $72.73 CAD → |
| – | Thermopile | EC-012 | $88.33 CAD → |
| – | Fully assembled pilot, NG | EC-015 | $141.60 CAD → |
| – | Fully assembled pilot, LP | EC-016 | Request it |
| – | Pilot gasket | EC-021 | $24.44 CAD → |
| – | S.I.T. piezo ignitor | EC-023 | $44.25 CAD → |
| – | Burner switch | EC-026 | $30.00 CAD → |
| – | Fan controller, 115V, with knob | EC-039A | $119.51 CAD → |
| – | Fan controller knob | EC-040 | $8.85 CAD → |
| – | Heyco strain relief | EC-044 | $73.29 CAD → |
| – | DV vent kit with coupleroption | EC-061 | Request it |
| – | Convection blower, 115V | EC-069 | $293.33 CAD → |
| – | Log set with embers, complete | EGWP-072 | Request it |
| – | Relief door gasket only | EGWP-087 | Request it |
| – | Window channel tape | EGWP-089 | Request it |
| – | One-piece glass with tape | EGWP-090 | $363.40 CAD → |
| – | Inner door only, painted | EGWP-092 | Request it |
| – | Burner control assembly, LP | EGWP-099 | Request it |
| – | Burner control assembly, NG | EGWP-100 | Request it |
| – | Door hinge pin, silver | EGWP-510 | $66.00 CAD → |
| – | Fireplace screen | EGWP-513 | Request it |
| – | Shoulder bolt, hardened bushing and nut (set of 2) | EF-124 | $69.64 CAD → |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| – | Bedford Arch door | 30-059 | Request it |
| – | Bedford Gothic filigree door | 30-065 | Request it |
| – | Bedford top | 50-282 | Request it |
| – | Bedford front posts (right and left) | 50-283 |
The Westport & Bedford manual does not describe the label's location in words, but its body parts diagram shows the rating plate (label), part 30-049, at the back of the stove beside the rear shield. The rating plate shows which gas the stove is built for, and a stove converted to the other gas should carry a conversion label on the rating plate. Your installer should also have recorded the model, serial number, gas type and orifice sizes on the installation data sheet at the back of the manual.
Source: Enviro C-10238, p. 32; C-10238, p. 1; C-10238, p. 22; C-10238, p. 35
Enviro lists both Bedford manuals as archived, and both are combined Westport & Bedford owner's manuals, so the same files also cover the Westport of that period. C-10238 is listed from February 5, 2003 to June 23, 2004 and C-10168 from December 8, 2003; the two editions carry essentially the same instructions and an identical parts list (page 30), so either one will do. Use the Bedford pages: the dimensions and clearances on page 6, the shared body and Bedford parts list on page 30, and the Bedford parts diagram on page 33. The Westport cast parts list on page 31 does not apply to the Bedford.
Source: Enviro C-10238, p. 1; C-10238, p. 3; C-10238, p. 30; C-10168, p. 30
The Bedford has a standing pilot lit by hand with the gas control knob; a battery-operated electronic igniter sparks it when you push the knob in. Before lighting, smell all around the stove and near the floor for gas; if you smell gas, do not light anything and call your gas supplier from a neighbour's phone. The valve has a lockout, so the pilot cannot be relit until the thermocouple has cooled. If the knob does not pop up when released, or the pilot will not stay lit after several tries, turn the knob to OFF and call a service technician or your gas supplier. To shut the stove off, flip the burner switch to off, then turn the gas control knob clockwise to OFF.
Source: Enviro C-10238, p. 26
If there is no spark when you push the pilot knob, the battery in the electronic ignition module may need replacing (one AA battery). Other no-spark causes in the troubleshooting chart are a bad ignitor connection, a broken or misaligned spark electrode, or a failed electronic module. A pilot that lights but will not stay lit points to the thermocouple circuit (a loose connection at the valve, a pilot flame too small to wrap the thermocouple, or a thermocouple reading under 7 mV) or to air in the gas line; a burner that will not stay lit points to the thermopile, which needs at least 200 mV with the burner on. Electrode, thermocouple and gas pressure checks are work for a qualified service technician.
Source: Enviro C-10238, p. 28; C-10238, p. 29; C-10238, p. 2
Yes. The Bedford has a millivolt gas control that uses the pilot flame to make enough electricity to run the main burner, so it operates without electrical power, and its pilot igniter runs on a battery. The optional blower does need power: it plugs into a grounded three-prong outlet.
Source: Enviro C-10238, p. 21; C-10238, p. 26; C-10238, p. 28
Never clean the glass while it is hot. On a cold start, condensation can form on the glass, which is normal, but it lets dust and lint cling, and the paint curing can leave a slight film, so Enviro recommends cleaning the glass after about the first two weeks of use and then usually no more than two or three times a season. Use a mild glass cleaner and a soft cloth; abrasive cleaners damage the glass and the gold surfaces. Make sure the door is properly fastened again before relighting.
Source: Enviro C-10238, p. 27; C-10238, p. 29
Do not run the stove with the glass front removed, cracked or broken; replacement must be done by a licensed or qualified service person. The glass is ceramic and must be a factory replacement bought from an Enviro dealer: the parts list has the one-piece glass with tape (EGWP-090), the window channel tape (EGWP-089) and the inner door complete with glass and handles (50-463). The new glass goes in with the large bulb of the gasket tape against the stove and the tape joint in a bottom corner, held to the frame with high temperature RTV that is left to dry for 2 hours before the door goes back on.
Source: Enviro C-10238, p. 2; C-10238, p. 27; C-10238, p. 30
Yes, with a conversion kit installed by a qualified service technician. The parts list gives 30-002 (natural gas to propane) and 30-001 (propane to natural gas) for a top-vented stove, and 30-006 and 30-005 for a rear-vented one. A kit holds a 50% turn-down HI-LOW regulator, a pilot injector, a main burner orifice, instructions and conversion labels. The technician swaps the valve regulator, the pilot injector and the main orifice (top vent #39 DMS natural gas or #53 DMS propane; rear vent #46 or #55), leak tests the gas line and puts the conversion stickers on the valve and the rating plate.
Source: Enviro C-10238, p. 22; C-10238, p. 30
The Bedford is direct vent: all combustion air comes from outside through the vent pipe, and the venting must be installed by a qualified installer. It ships as a 30,000 Btu top-vented stove. For a horizontal termination off the top it needs at least 24" (61 cm) of vertical pipe before the first 90° elbow. The total vent length must stay within the chart (up to 25 feet), with up to four 90° or eight 45° elbows, and the built-in restrictor plate is set from the chart. It can also be rear vented: straight out a flat wall at 20,000 Btu with no more than 10" of pipe and the rear vent orifice, or at 30,000 Btu with a 36" snorkel kit; rear venting is not for corner installations. Top venting is certified to 4500 ft and rear venting to 2000 ft.
Source: Enviro C-10238, p. 4; C-10238, p. 8; C-10238, p. 16; C-10238, p. 18; C-10238, p. 20
Have the stove inspected before first use and every year after by a qualified service person, and have the venting system inspected each year for blockage and deterioration. Between services, check that the burner ports are clean and clear, that the pilot head is not blocked and that the pilot flame is blue with no or very small yellow tips. Keep the control compartment, burner and air passages clean; lint from carpets and bedding can mean more frequent cleaning.
Source: Enviro C-10238, p. 2; C-10238, p. 27; C-10238, p. 28

Sale price $307.69 CAD Regular price $338.99 CAD
| – | Bedford rear posts (right and left) | 50-284 | Request it |
| – | Bedford ash shelf | 50-285 | Request it |
| – | Bedford side (right and left) | 50-286 | Request it |
| – | Bedford front | 50-287 | Request it |
| – | Bedford front bottom rail | 50-288 | Request it |
| – | Bedford side bottom rails (right and left) | 50-289 | Request it |
| – | Bedford aluminum inserts (set of 4) | 50-290 | Request it |
| – | Bedford door screen | 50-357 | Request it |