The current Enviro Westley manuals are C-15626 (the Westley IPI and Westley-D) and C-16265 (the millivolt Westley-820 and Westley-821), both free PDFs from enviro.com. The IPI Westley lights itself from the Proflame 2 remote, while on a Westley-820 or 821 you light the pilot by hand with the gas control knob and piezo ignitor. The rating label with the model and serial number is on a plate hanging on the back of the stove.
Owner's manuals for the Enviro Westley cast iron freestanding gas stove listed by Enviro since 2018, IPI and millivolt, with the factory parts lists and part numbers, key specs and answers to common Westley questions, each taken from the official Enviro manual with the page number.
Last updated · From Enviro docs C-15626 rev R3 and C-16265 · Answers drafted from the manuals; staff review pending
Westley (IPI)
Intermittent pilot ignition with an S.I.T. 885 valve and the Proflame 2 remote and integrated fireplace controller (IFC), which light the pilot and burner for you. The remote also runs six flame levels, a room thermostat and six fan speeds. Enviro's manuals for it are titled Westley IPI from December 2018; the current R3 edition, from December 2021, is titled Westley / Westley-D and lists a 2021 IPI pilot assembly.
Manuals: C-15626
Westley-D
The IPI Westley body with the Dexen control system. The Westley manual covers it, but sends owners to the separate Dexen user manual supplied with the stove for remote operation, wiring, valve details, troubleshooting and Dexen-specific replacement parts. Covered from the R3 edition (December 2021).
Manuals: C-15626
Westley-820 (millivolt)
S.I.T. 820 Nova millivolt valve behind the front valve access door. You light the pilot by hand with the gas control knob and piezo ignitor, then run the burner from a burner switch and a HI/LO knob; the convection fan has its own control knob, and an optional remote or wall thermostat can be used. Manual listed from August 2021.
Manuals: C-16265
Westley-821 (millivolt, 7-day pilot)
Same as the Westley-820 but with the S.I.T. 821 Nova valve: you hold the knob until the valve beeps when lighting the pilot, and the on-demand pilot shuts itself off after 7 consecutive days without the main burner running.
Manuals: C-16265
Find your model and serial number: The rating label and lighting instructions are on a plate hanging on the back of the unit.

Sale price $120.00 CAD Regular price $132.99 CAD

Sale price $22.00 CAD Regular price $24.99 CAD

Sale price $270.00 CAD Regular price $297.99 CAD
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
Westley Owner's Manual R3 (Westley IPI / Westley-D)
C-15626 rev R3 · Dec 1, 2021 – Present · 52 pages · Current
Westley 820-821 Owner's Manual (millivolt)
C-16265 · Aug 1, 2021 – Present · 46 pages · Current
Can't open a link? Enviro lists every version on its manuals pages: Enviro Westley manuals.
From the parts lists in the Enviro Westley manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Door latch mechanism with spring (set of 2) | 50-1285 | Request it |
| 2 | Pilot shield | 50-3514 | Request it |
| 3 | PSE IPI pilot assembly (2021) | 50-4058 | $120.00 CAD → |
| – | IPI LP pilot orifice (2021) | 50-4080 | $22.00 CAD → |
| 4 | S.I.T. 885 valve with NG stepper motor | 50-2682 | $270.00 CAD → |
| 5 | Proflame 2 IFC | 50-3791 | $342.06 CAD → |
| – | Proflame 2 IFC wire harness (0.584.924) | 50-3030 | Request it |
| 6 | Battery holder, 4 x AA | 50-3027 | $41.82 CAD → |
| 7 | Proflame 2 transmitter (0.584.040) | 50-3265 | $185.45 CAD → |
| 8 | Burner pan assembly | 50-3729 | $260.00 CAD → |
| 9 | Burner tray assembly | 50-3730 | Request it |
| 10 | Burner mounts (set of 4) | 50-3731 | Request it |
| 11 | Convection fan only | EC-069 | $293.33 CAD → |
| 12 | Heyco strain relief | EC-044 | $73.29 CAD → |
| 13 | Domestic power cord (115 V) | EC-042 | $55.38 CAD → |
| 14 | Side door complete | 50-3734 | Request it |
| 15 | Side door glass with gasket (9.63 x 13.21 in) | 50-3735 | Request it |
| 16 | Replacement safety screen, side | 50-3716 | Request it |
| 17 | Front door complete | 50-3732 | Request it |
| 18 | Front door glass with gasket (19.06 x 14.21 in) | 50-3733 | $266.67 CAD → |
| 19 | Replacement safety screen, front | 50-3715 | Request it |
| 20 | Ceramic log set (8 pieces)option | 50-3728 | $448.60 CAD → |
| 21 | Ceramic fluted liner (1 piece)option | 50-3736 | Request it |
| – | Westley-IPI owner's manual | 50-3737 | Request it |
| – | NG to LP stepper motor onlyoption | 50-3753 | $187.20 CAD → |
| – | LP to NG stepper motor onlyoption | 50-3870 | $115.00 CAD → |
| – | Metallic black touch-up paint, 12 oz can | PAINT-12-MB | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Door latch mechanism with spring (set of 2) | 50-1285 | Request it |
| 2 | Pilot shield | 50-3514 | Request it |
| 3 | Pilot assembly (PSE-NA479) | 50-4083 | $130.00 CAD → |
| 4 | S.I.T. 821 Nova valve (7-day), convertible, Westley-821 models | 50-3660 | → |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 22 | Cast top, painted | 50-3717 | Request it |
| – | Cast top, Antique Bronze | 50-3718 | Request it |
| 23 | Cast front, painted | 50-3719 | Request it |
| – | Cast front, Antique Bronze | 50-3720 |
On the rating label. The rating label and the lighting instructions are on a plate hanging on the back of the stove, on the IPI Westley and on the millivolt Westley-820 and 821. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual. Enviro asks for the appliance serial number on warranty claims, and the warranty registration has to be submitted within 90 days of purchase.
Source: Enviro C-15626, p. 6; C-16265, p. 6; C-16265, p. 1; C-15626, p. 52; C-15626, p. 51
Check the model on the rating label, or look at the controls. A Westley or Westley-D lights itself from the remote, and its lighting label says not to light the pilot by hand. Its manual is C-15626, whose current edition covers both; a Westley-D owner also needs the separate Dexen user manual supplied with the stove. The Westley-820 and Westley-821 are millivolt stoves: you light the pilot by hand with the gas control knob and piezo ignitor, and run the burner with a burner switch and a HI/LO knob. Their manual is C-16265. On the 821 the valve beeps when the pilot is ready, and the pilot shuts itself off after 7 days without main burner use. IPI Westleys from before December 2021 are covered by archived editions of C-15626 titled Westley IPI; the documents list above shows the dates.
Source: Enviro C-15626, p. 1; C-15626, p. 7; C-15626, p. 9; C-15626, p. 47; C-15626, p. 52; C-16265, p. 1; C-16265, p. 7; C-16265, p. 8; C-16265, p. 9; C-16265, p. 46
The Westley-820 and 821 have a pilot you light by hand, following the lighting label. Use only your hand on the gas control knob: if it will not push in or turn by hand, don't try to repair it, call a qualified service technician. If the knob does not pop up when released, stop and call your service technician or gas supplier right away. The valve has a lockout that will not let the pilot relight until the thermocouple has cooled. If the pilot will not stay lit after several tries, turn the knob clockwise to OFF and call your service technician or gas supplier. If you smell gas, don't light anything and follow the gas safety steps on the label.
Source: Enviro C-16265, p. 7; C-16265, p. 8; C-16265, p. 9
The IPI Westley lights itself. Don't try to light the pilot by hand. Press ON/OFF on the remote; the controller (IFC) beeps once, lights the pilot and then the main burner, which takes about 10 seconds. The IFC makes one ignition attempt lasting about 60 seconds, and locks out if it senses no flame. If the stove will not operate, follow the steps to turn off the gas and call your service technician or gas supplier. A Westley-D is run from the Dexen remote instead, described in the separate Dexen user manual.
Source: Enviro C-15626, p. 7; C-15626, p. 9; C-15626, p. 11; C-15626, p. 44
Check the simple causes first: the remote may be too far from the stove, or its batteries may be low or dead. A battery icon on the remote display means its three AAA batteries are low. If the IFC does not beep when you press ON/OFF, its four AA backup batteries are low. After changing batteries, re-sync the remote to the IFC with the reset button. The replacement Proflame 2 transmitter is part 50-3265. On a millivolt Westley-820 or 821 the remote is an option: leave the burner switch in the remote/thermostat position and follow the remote's own instructions.
Source: Enviro C-15626, p. 14; C-15626, p. 45; C-15626, p. 47; C-16265, p. 8; C-16265, p. 40
The LED on the Proflame 2 controller (IFC) of an IPI Westley blinks a code. One blink means a low battery condition (below 4 V). Two blinks mean a parasitic pilot flame. Three blinks mean the system is locked out, for example after a failed ignition; the IFC makes one ignition attempt of about 60 seconds before it locks out. Remove whatever caused the lockout, then reset the IFC. For a Westley-D, troubleshooting is in the separate Dexen user manual. If the pilot still won't light, installation and repair should be done by a qualified service person.
Source: Enviro C-15626, p. 44; C-15626, p. 45; C-15626, p. 46; C-15626, p. 3
Often it is the 7-day shutdown. On a Westley-821 the pilot shuts itself off after 7 consecutive days without main burner use; relight it by turning the knob to OFF and lighting it again. On an IPI Westley left in continuous pilot (CPI) mode, the pilot also shuts off after 7 continuous days without main burner use; toggle the remote to IPI and back to CPI, or turn the stove on, to restart it. Enviro recommends CPI in winter when it is below 50°F (10°C) outside. Otherwise the troubleshooting tables point to the thermocouple circuit on the millivolt models and the flame sensor circuit on the IPI model. If the pilot has gone out on its own, open the glass door and wait 5 minutes before relighting, and have repairs done by a qualified service person.
Source: Enviro C-16265, p. 8; C-16265, p. 40; C-15626, p. 11; C-15626, p. 45; C-15626, p. 3
Clean the glass only when the stove is cold. Condensation on a cold start is normal, and the first paint cure can leave a slight film behind the glass. After the first burn, which Enviro says to run on high with the fan off for the first 4 hours, let the stove get cold and clean the glass. Plan to clean it again about two weeks after installation, then no more than two or three times a season. Use a mild glass cleaner and a soft cloth; abrasive cleaners damage the glass and painted surfaces.
Source: Enviro C-15626, p. 5; C-15626, p. 15; C-15626, p. 16
Stop using the stove: don't run it with the glass removed, cracked or broken. The glass is a high temperature ceramic and needs a factory replacement bought from an Enviro dealer; no substitute materials are allowed. Removing and replacing the glass in the door must be done by a licensed or qualified service person. The replacement glass comes with a new gasket and is set with high temperature silicone. The front and side door glass are separate parts, the same on every Westley: 50-3733 for the front door glass with gasket (19.06 x 14.21 in), 50-3735 for the side door glass with gasket (9.63 x 13.21 in), and 50-3732 and 50-3734 for the complete front and side doors.
Source: Enviro C-15626, p. 15; C-15626, p. 47; C-16265, p. 41
Yes, with the conversion kit, installed by a qualified service agency only. Both Westley manuals list a burner orifice (#38 natural gas, #52 propane), a pilot orifice, a steel air deflector that goes on the burner tray for propane conversions only, an instruction sheet and a conversion label. For the IPI Westley the kit also has a servo regulator with diaphragm for the S.I.T. valve, and the pilot orifice is 0.2 for natural gas or 0.14 for propane; its parts list, though, sells the conversion as NG to LP (50-3753) and LP to NG (50-3870) stepper motors, so confirm the kit with your dealer. On the millivolt Westley-820/821 the installer flips the conversion screw in the S.I.T. valve, and the LP pilot orifice is supplied with the stove. Either way the installer leak-tests the connections, checks the inlet and manifold pressures and fits the conversion label on or close to the rating label.
Source: Enviro C-15626, p. 18; C-15626, p. 19; C-15626, p. 47; C-16265, p. 1; C-16265, p. 14; C-16265, p. 15; C-16265, p. 16
Enviro says the stove should be inspected before first use and at least once a year by a qualified service person, with more frequent cleaning if there is a lot of lint from carpeting or bedding. At least once a year check that all the burner ports are clear and that nothing blocks the pilot; the pilot flame should be blue with little or no yellow on the tips. Inspect the venting every year for blockage and signs of deterioration; Enviro recommends a qualified agency do that. Once a year remove the logs and check them for deterioration or heavy soot (a little on the underside is normal), then reset them as the manual shows. With the burner out, some burner warpage after long use is normal, and it is a good time to vacuum loose burner media and debris from the firebox. Wipe the painted surfaces with a damp cloth, never while hot.
Source: Enviro C-15626, p. 3; C-15626, p. 14; C-15626, p. 17; C-15626, p. 42

Sale price $342.06 CAD Regular price $376.99 CAD
| 4 | S.I.T. 820 Nova valve, convertible, Westley-820 models | 50-1421 | Request it |
| 5 | 120 ceramic fan temperature sensor | EC-001 | $77.79 CAD → |
| 6 | Fan controller, 115 V, with knob and decal | EF-045 | $40.00 CAD → |
| 7 | Fan controller knob with decal | EC-040 | $8.85 CAD → |
| 8 | Control panel and decal | 50-2989 | Request it |
| 9 | S.I.T. piezo ignitor | EC-023 | $44.25 CAD → |
| 10 | FPI burner switch | EC-026 | $30.00 CAD → |
| 11 | Burner pan assembly | 50-3729 | $260.00 CAD → |
| 12 | Burner tray assembly | 50-3730 | Request it |
| 13 | Burner mounts (set of 4) | 50-3731 | Request it |
| 14 | Convection fan only | EC-069 | $293.33 CAD → |
| 15 | Heyco strain relief | EC-044 | $73.29 CAD → |
| 16 | Domestic power cord (115 V) | EC-042 | $55.38 CAD → |
| 17 | Side door complete | 50-3734 | Request it |
| 18 | Side door glass with gasket (9.63 x 13.21 in) | 50-3735 | Request it |
| 19 | Replacement safety screen, side | 50-3716 | Request it |
| 20 | Front door complete | 50-3732 | Request it |
| 21 | Front door glass with gasket (19.06 x 14.21 in) | 50-3733 | $266.67 CAD → |
| 22 | Replacement safety screen, front | 50-3715 | Request it |
| 23 | Ceramic log set (8 pieces)option | 50-3728 | $448.60 CAD → |
| 24 | Ceramic fluted liner (1 piece)option | 50-3736 | Request it |
| 25 | B-vent drafthood adaptoroption | 50-3667 | Request it |
| – | Westley 820/821 owner's manual | 50-4127 | Request it |
| – | Metallic black touch-up paint, 12 oz can | PAINT-12-MB | Request it |
| Request it |
| 24 | Cast skirt, painted | 50-3721 | $74.77 CAD → |
| – | Cast skirt, Antique Bronze | 50-3722 | Request it |
| 25 | Cast right side, painted | 50-3723 | Request it |
| – | Cast right side, Antique Bronze | 50-3724 | Request it |
| 26 | Cast left side, painted | 50-3725 | Request it |
| – | Cast left side, Antique Bronze | 50-3726 | Request it |
| 27 | Cast leg, painted (1 piece) | 50-3256 | Request it |
| – | Cast leg, Antique Bronze (1 piece) | 50-3727 | Request it |