Manuals & parts · Freestanding pellet stove
Quick answer
The current Enviro P3 pellet stove manual is C-16235 (P3-2), a free PDF from enviro.com. The original P3 uses the archived P3 owner's manuals from 2014 to 2021, the latest being C-15544: check the model on the rating label and pick the manual whose dates cover your install. The rating label with the serial number is on the back of the ash pan access cover.
Owner's manuals for every Enviro P3 pellet stove since 2014, the factory parts list with part numbers, key specs, and answers to common P3 questions, each taken from the official Enviro manual with the page number.
Last updated · From Enviro docs C-16235 and C-15544 · Answers drafted from the manuals; staff review pending
P3-2
Dec 2021 onward. Rated 80.2% HHV efficiency when fitted with the optional top vent adapter kit (50-4116). The slider damper is set at the factory.
Manuals: C-16235
P3
Jun 2014 to Dec 2021. The 2018 manual (C-15544) lists 66.2% HHV efficiency, has no top vent adapter kit section, and says the slider damper must be set at installation. Its parts list is the same as the P3-2 list.
Manuals: C-15544, C-14635, C-14329
Find your model and serial number: The rating label is on the back of the ash pan access cover. (Enviro C-16235, p. 7)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
P3-2 Owner's Manual
C-16235 · Dec 15, 2021 – Present · 37 pages · Current
Can't open a link? Enviro lists every version on its manuals pages: Enviro P3 manuals.
From the parts lists in the Enviro P3 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | 120 °F ceramic fan temperature sensor | EC-001 | $77.79 CAD → |
| 2 | Auger motor, 115 V | EF-001 | $166.67 CAD → |
| 3 | High limit temperature sensor 200 °F (93 °C), manual reset | EF-016 | $79.80 CAD → |
| 4 | Vacuum switch, 115 V | EF-017 | $76.36 CAD → |
| 5 | Silicone hose | EF-018 | $38.00 CAD → |
| 6 | Stainless steel ash pan latch | 50-2588 | $64.78 CAD → |
| 7 | Domestic power cord, 115 V | EC-042 | $55.38 CAD → |
| 8 | 400 W ignitor, 115 V | 50-619 | $56.67 CAD → |
| 9 | Exhaust blower assembly, 115 V | 50-901 | Request it |
| 10 | 60 mm tangential blower, Mini, 115 V | 50-1217 | $273.85 CAD → |
| 11 | Leveling legs (set of 4) | 50-1296 | Request it |
| 12 | Hopper switch (magnetic) | 50-2052 | $63.84 CAD → |
| 13 | P3 glass with gasket | 50-2942 | Request it |
| 14 | LED motherboard | 50-2943 | $258.46 CAD → |
| 15 | LED daughterboard | 50-2944 | $130.91 CAD → |
| 16 | Control decal | 50-2948 | Request it |
| 17 | Ash pan with stainless steel latch | 50-1969 | $169.09 CAD → |
| 18 | Draft slider | 50-1178 | Request it |
| 19 | Starter pipe, 3" | 50-1185 | $92.93 CAD → |
| 20 | Burn pot | 50-1922 | Request it |
| 21 | Burn pot liner | 50-1923 | Request it |
| 22 | Auger with paddles weldment | 50-1161 | $192.73 CAD → |
| 23 | Auger stop plate | 50-2206 | $82.22 CAD → |
| 24 | P3 hearth pad with mounting hardware | 50-2929 | Request it |
| 25 | P3 cabinet sides and ash shelf, painted | 50-2945 | Request it |
| 26 | P3 cabinet sides and ash shelf, red | 50-2946 | Request it |
| 27 | P3 cabinet sides and ash shelf, ivory | 50-2947 | Request it |
| 28 | P3 cast top | 50-2949 | Request it |
| 29 | P3 cast hopper lid | 50-2950 | Request it |
| 30 | P3 cast door assembly | 50-2951 | Request it |
| 31 | P3 firebox panel set with insulation | 50-2952 | Request it |
| 32 | Top cast mount plate | 50-2953 | Request it |
| 33 | Hopper hinge set (left and right) | 50-2954 | Request it |
| 34 | Top cabinet mount set (2) | 50-2955 | Request it |
| 35 | Bottom cabinet mount set (2) | 50-2956 | Request it |
| 36 | Door hinge weldment | 50-2957 | Request it |
| 37 | Louver bracket set (left and right) | 50-2958 | Request it |
| 38 | Louver set | 50-2959 | Request it |
| 39 | P3 rear grill | 50-2960 | Request it |
| 40 | Steel door latch | 50-2961 | $42.56 CAD → |
| 41 | Ash pan access door | 50-2962 | Request it |
| 42 | Ash pan access door hinge set (2) | 50-2963 | Request it |
| 43 | Motherboard mounting bracket | 50-2964 | Request it |
| 44 | Daughterboard mount box | 50-2965 | Request it |
| 45 | P3 heat exchanger scraper rod | 50-2966 | $55.32 CAD → |
| 46 | Machined door latch nut | 50-2967 | Request it |
| – | Chrome plated ash shelf | 50-3006 | Request it |
| – | 25 ft extension probe | 50-3005 | Request it |
| – | P3 door gasket, 54", with joint tape | 50-2968 | $69.09 CAD → |
| – | Aluminum hose barb (vacuum line) | EF-019 | $68.10 CAD → |
| – | Auger brass bushings (set of 2) | 50-1806 | $80.00 CAD → |
| – | External exhaust back, for the optional external exhaust kit | EF5-143 | Request it |
| – | External exhaust box, for the optional external exhaust kit | EF5-144 | Request it |
| – | External exhaust bottom, for the optional external exhaust kit | EF5-145 | Request it |
| – | External exhaust kit (3")option | 20-070 | Request it |
| – | Circuit board 2 A fuse, 115 V (single) | 50-2075 | $36.32 CAD → |
| – | Circuit board 5 A fuse, 115 V (pair) | 50-833 | $40.91 CAD → |
| – | 5/8" ID auger collar with screw | 50-968 | $65.11 CAD → |
| – | Wire harness | 50-1157 | $172.36 CAD → |
| – | Auger stops (clear tube) | 50-1559 | Request it |
| – | Burn pot scraper tool | 50-1254 | Request it |
| – | Cleaning brush | EF-156 | $36.83 CAD → |
| – | P3 door tool | 50-2969 | $63.84 CAD → |
| – | Top vent adapter kit, vertical installations (shown on the P3-2 parts diagram)option | 50-4116 | Request it |
On the rating label, which is on the back of the ash pan access cover. The installer should also write the model and serial number on the installation data sheet at the back of the manual. Enviro needs the unit serial number for warranty claims, including warranty parts.
Source: Enviro C-16235, p. 7; C-16235, p. 36; C-16235, p. 35
Check the model on the rating label and your install date. A P3-2 (December 2021 and later) uses C-16235. An original P3 uses the archived P3 owner's manuals: C-15544 (August 2018 to December 2021), C-14635 (May 2015 to August 2018) or C-14329 (June 2014 to May 2015). The 2018 P3 manual and the P3-2 manual share the same parts list. The P3-2 manual adds the optional top vent adapter kit (50-4116) and is rated 80.2% HHV with it, where the 2018 P3 manual lists 66.2% HHV. The P3-2 slider damper is set at the factory; the 2018 P3 manual says it must be set at installation.
Source: Enviro C-16235, p. 4; C-16235, p. 18; C-16235, p. 21; C-16235, p. 31; C-16235, p. 32; C-15544, p. 4; C-15544, p. 21; C-15544, p. 31; C-15544, p. 32
Check the burn pot liner is clean and seated against the ignitor tube and that there are pellets in the hopper, then press the green Power button. The blue LED beside it flashes during start-up. After about 10 to 15 minutes the LED turns solid and the room air blower comes on. On a first start, or after the hopper has run empty, the auger needs priming. Never run the stove with the door or ash pan open.
Source: Enviro C-16235, p. 20; C-16235, p. 21
Press the Power button. The stove runs a shut-down cycle: the fire takes about 5 minutes to burn out and the fans keep running until the stove has cooled. Never unplug a running stove, or unplug it while the combustion fan is running, because that may release smoke into the home. If the fire looks unusually high, turn it off with the Power button, not the plug. For power failures, Enviro recommends 3 to 5 feet (91 to 152 cm) of vertical vent pipe on through-wall installs for natural draft, and a fresh air intake, since without one the stove may smoke during a power failure. Venting is installation work: Enviro recommends an authorized dealer or installer.
Source: Enviro C-16235, p. 21; C-16235, p. 22; C-16235, p. 15; C-16235, p. 12; C-16235, p. 11
E2: the vacuum switch contacts have been open for more than a minute and the auger has stopped. Listed causes include a pinched or blocked vacuum hose or hose barb, a blocked vent, the air damper closed or set too low, strong negative pressure in the room, or a failing vacuum switch or combustion blower. E3: proof of fire failure. The fire did not light or has gone out and the exhaust temperature has dropped below 120 °F (49 °C); check the hopper for pellets, prime the auger if needed and clean the burn pot. E4: the 200 °F (93 °C) high limit on the hopper has tripped, or the magnetic hopper lid switch is open, so check the lid is fully closed. If the high limit tripped, call your dealer to reset it and find out why the stove overheated; if you see smoke when you slowly open the lid, keep it closed. S1 is a service reminder after a set number of run hours, not a fault. Press Power to reset the board after a code. Enviro says troubleshooting should be done by qualified technicians or installers.
Source: Enviro C-16235, p. 20; C-16235, p. 27; C-16235, p. 28
Every two to three days, with the stove cold, take out the burn pot liner and scrape its holes clear. Check the liner daily for clinkers, the hard lumps that impurities in the fuel form and that block the air holes. If the fire keeps building up and overflowing the burn pot, the pellets may be poor, the stove may need cleaning or the air may need adjusting. Enviro lists a burn pot scraper tool, 50-1254.
Source: Enviro C-16235, p. 23; C-16235, p. 7; C-16235, p. 32
The heat exchanger tubes are cleaned every 2 to 3 days with the scraper rod behind the louvers above the door, only when the stove is cold. Twice a year, the exhaust passages behind the three clean-out covers in the ash pan compartment must be cleaned and vacuumed to stop fly ash building up. You need a 5/16" socket and a vacuum with a fine filter bag.
Source: Enviro C-16235, p. 23; C-16235, p. 24; C-16235, p. 25
Every 2 to 3 days: the burn pot and liner, the heat exchanger tubes and the door glass (only when cold, with a soft cloth, a gas appliance glass cleaner or a damp paper towel dipped in fly ash). Weekly: empty the ash pan into a metal container kept away from combustibles, vacuum the ash pan compartment, brush and vacuum the firebox, and check the ash pan and door gaskets. Twice a year or every two tons of pellets: the exhaust vent (Enviro recommends a dealer for this), the air intake, the air wash above the glass, the two blowers (unplug the stove first and do not oil the motors) and the passages behind the clean-out covers. At the end of the season, unplug the stove and have it thoroughly cleaned and serviced. Never run it with broken glass: replacement glass (50-2942) must be bought and installed by an Enviro dealer.
Source: Enviro C-16235, p. 23; C-16235, p. 24; C-16235, p. 26
Wood pellets only, with up to 3% ash content; other fuels void the warranty, and burning cord wood is prohibited by law. Enviro recommends pellets that meet P.F.I. standards: 1/4" to 5/16" diameter, 8% moisture maximum, 1% ash for premium grade or 3% for standard grade, and a heat content of about 8,200 BTU per pound minimum. High-ash fuel can mean cleaning the stove daily. Store pellets in a dry place at least 36" (1 m) from the stove.
Source: Enviro C-16235, p. 7; C-16235, p. 5
Check the stove is plugged into a working 115 to 120 V outlet, that the thermostat is calling for heat if the board is in Thermostat mode, and whether an E code is showing. If the auger is not feeding after a first start or running out of pellets, it needs priming; press Power again if E3 shows while it fills. If pellets feed and the combustion blower runs, the stove should light or at least start smoking; make sure the burn pot and liner sit square to the ignitor and air tube. A jammed auger, a failed ignitor (400 W ignitor 50-619) or blown circuit board fuses are checks for a technician: Enviro says all troubleshooting should be done by qualified technicians or installers, and electrical checks only with the stove unplugged, by someone who knows electrical systems. If the heat level buttons seem to do nothing, a flashing Power LED means start-up is still running, and a flashing Auto LED means the stove is in Suspend mode until the room cools below the set point.
Source: Enviro C-16235, p. 27; C-16235, p. 28; C-16235, p. 29; C-16235, p. 31
Sale price $76.36 CAD Regular price $84.99 CAD