Where is the rating label on an Enviro EG31 or Focus?
Under the control panel. The label is attached to a rectangular metal sheet that is chained to the fireplace; the EG31 and Focus manuals give the same location. The installer should also have recorded the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-14867, p. 6; C-13832, p. 5; C-14867, p. 36
Is the Enviro Focus the same insert as the EG31?
The manuals support that the Focus is the EG31's predecessor. Enviro lists the Focus manuals on the EG31 family page; the Focus manuals carry the same owner's manual number, EG31-118, as the EG31 manuals; the Focus components use the same EG31- part numbers and the same S.I.T. Nova convertible valve, 50-1421; and the EG31 manual reuses the Focus parts diagram, labelled EG31 Focus, March 2008. The Focus manuals add the bay window, surround, face and cast iron front options; the EG31 manuals add a safety screen, 50-3075, and the Contemporary and Cape Cod surround panels.
Source: Enviro C-13832, p. 1; C-13832, p. 24; C-14867, p. 32; C-14867, p. 33; C-14867, p. 6
Which EG31 or Focus manual do I need?
Enviro lists every EG31 and Focus manual as archived. For an EG31, use C-14867 (the EG31-S edition, dated March 29, 2016) or C-14475 from 2014; the two differ only in the exterior dimensions drawing. For a Focus from 2006 on, use the edition that matches your date: C-13832 (January 2013) is the last, then C-11536, C-11288 and C-11074, all with the convertible valve 50-1421. Focus inserts from 2003 to 2006 have a separate natural gas or propane valve (EC-006 or EC-007) and match C-10472 or C-10152. The parts lists are in the back of each manual.
Source: Enviro C-14867, p. 36; C-13832, p. 24; C-10472, p. 20
How do I light the pilot on an EG31 or Focus?
The insert has a standing pilot that you light by hand with the piezo ignitor. The pilot is on the left, under the front log. The gas valve has a lockout that will not let the pilot relight until the thermocouple has cooled; if the knob does not pop up when released, stop and call your service technician or gas supplier. If the pilot does not stay lit after several tries, turn the knob to OFF and call them.
- Read the safety information on the lighting label, then turn off all electrical power to the insert. (C-14867, p. 7)
- Turn the gas control knob clockwise to OFF. (C-14867, p. 7)
- Open the door and wait five minutes to clear out any gas, then close it. If you smell gas, stop and follow the gas-smell instructions. (C-14867, p. 7)
- Turn the gas control knob counter-clockwise to PILOT, push it in fully and hold it while pressing the piezo ignitor until the pilot lights. (C-14867, p. 7)
- Keep the knob pushed in for about 30 seconds after the pilot lights, then release it. If the pilot goes out, repeat from the waiting step. (C-14867, p. 7)
- Turn the knob counter-clockwise to ON, flip the burner switch to ON, set the HI/LOW knob, and turn the electrical power back on. (C-14867, p. 7)
Source: Enviro C-14867, p. 7; C-14867, p. 30; C-13832, p. 6
Why does my EG31 or Focus pilot or burner keep going out?
For the pilot, the troubleshooting table points to the thermocouple circuit: a loose thermocouple at the back of the valve, a pilot flame that does not fully surround the thermocouple (gas pressure, pilot rate screw or a damaged pilot head), or a weak thermocouple (it must read more than 5 mV at the valve). If the pilot dies while you hold the knob in, there may be air in the gas line. If the burners go out, check the gas pressure, the flame on the thermopile (at least 300 mV with the burner on) and the thermostat wiring. On a B-vent installation, the 300°F (149°C) spill switch at the back shuts the insert off when flue gases spill; if it trips more than once, have a qualified service technician inspect the venting for blockage or down draft. If the pilot or burners go out on their own, open the glass door and wait 5 minutes before relighting.
Source: Enviro C-14867, p. 30; C-14867, p. 17; C-14867, p. 19; C-14867, p. 3
Does the EG31 work in a power outage, and how do I use the blower?
Yes, the fire does: the EG31 has a millivolt gas control that uses the pilot flame to generate the electricity to run the main burner, so it operates without electrical power. The blower needs power and must be plugged into a properly grounded three-prong outlet. It comes on by itself once the insert is up to temperature, about 20 minutes; turn the fan control knob to change its speed, or counter-clockwise until it clicks to turn it off. Enviro advises not running the blower below 1/3 speed, as it strains the windings and can cause early fan failure.
Source: Enviro C-14867, p. 22; C-14867, p. 8
How do I remove the EG31 or Focus blower to replace it?
The blower comes out with the gas and electrical tray. The parts list gives EC-069 for the 115 V convection blower and EC-001 for the 120°F (49°C) fan temperature sensor. The manual says repair should be done by a qualified service person, and the gas connection must be leak-tested afterwards.
- Turn the insert off, let it cool, and remove the glass door and the log set. (C-14867, p. 10)
- Remove the two T-20 screws in the centre of the burner tray, slide the burner tray top to the left and lift it out. Remove the brick panels. (C-14867, p. 10)
- Lift the surround panel straight up and out. Turn off the gas supply, undo the gas connection and disconnect the wiring at the side of the insert. (C-14867, p. 10)
- Remove the three T-20 screws holding the air deflector on the back firewall and the remaining screws holding the burner assembly, then lift the gas tray assembly out without damaging wires or gas lines. (C-14867, p. 10)
- Remove the screws on the back of the gas tray assembly to take off the blower and housing, and disconnect the fan temperature sensor wiring. (C-14867, p. 10)
- Reinstall in reverse order, leak-test every gas line with soap and water, and check the burner and blower work properly. (C-14867, p. 10)
Source: Enviro C-14867, p. 10; C-14867, p. 31; C-14867, p. 3
How do I remove the EG31 or Focus glass to clean it?
Condensation on a cold start is normal and clears as the insert warms, though it lets dust and lint cling to the glass, and the first paint cure leaves a film. Clean the glass about two weeks after installation, then no more than two or three times a season depending on use.
- Turn the insert off and wait until it has cooled down. Never clean the glass when it is hot. (C-14867, p. 9)
- On an EG31, lift the safety screen off: its four hooks sit in slots on each side of the cabinet. It must go back on before you run the insert. (C-14867, p. 26)
- Lift the decorative fascia or clip-on bay window up and out of the slots in the body of the unit. (C-14867, p. 9)
- Undo the two 5/16" bolts at the top of the door frame and lift the glass and frame away, taking care the glass does not fall out of the frame. (C-14867, p. 9)
- Check that the gasket on the back of the glass is attached and intact, then clean the glass with a mild glass cleaner and a soft cloth. Abrasive cleaners damage the glass. (C-14867, p. 9)
- Reinstall in reverse order and make sure the door is properly fastened before relighting. (C-14867, p. 9)
Source: Enviro C-14867, p. 9; C-14867, p. 3
The EG31 or Focus glass is cracked. What do I need?
Stop using the insert: do not operate it with the glass front removed, cracked or broken. The glass is a high temperature ceramic and needs a factory replacement bought from an Enviro dealer; no substitute materials are allowed, and removing and replacing the glass in the door must be done by a licensed or qualified service person. The parts list gives EG31-090 for the glass with tape, EG31-092 for the painted door only, 50-1822 for the door with glass and gasket and 50-634 for the dual bulb door gasket. A Focus bay window has its own 3-piece glass set: EG31-091 for the steel bay and 50-496 for the cast bay.
Source: Enviro C-14867, p. 10; C-14867, p. 31; C-14867, p. 32; C-13832, p. 26; C-13832, p. 29
Can I convert an EG31 or Focus from natural gas to propane?
Only with a certified conversion kit installed by a qualified service agency. On the convertible valve, the kit holds a burner orifice (#38 DMS natural gas, #52 DMS propane), a pilot injector (0.62 mm natural gas, 0.35 mm propane), an instruction sheet and a conversion label. The installer changes the burner orifice and pilot injector, flips the valve's conversion screw (red O-ring visible for propane), leak-tests every gas connection with soapy water, checks the pilot flame covers the thermocouple and thermopile, checks the burner on HI and LO and the inlet and manifold pressures, and fixes the conversion label on or near the rating label. The parts list gives 50-1435 (natural gas to propane) and 50-1434 (propane to natural gas) for the convertible valve, and also lists kits EG31-202 and EG31-200.
Source: Enviro C-14867, p. 11; C-14867, p. 12; C-14867, p. 13; C-14867, p. 32
Can an EG31 or Focus be B-vented instead of direct vented?
Yes, with a conversion kit fitted by a qualified installer. As a direct vent insert it uses two 3" liners, a vent length of 8ft to 25ft, and the restrictor ring above 15 feet. As a B-vent insert it draws its combustion air from the room and vents through 4" flex vent or certified Type B gas vent. Converting to B-vent needs a 300°F (149°C) manual reset spill switch, a drafthood, two air channels and a drafthood diverter (the parts list gives EG31-206 for the direct vent to B-vent kit and EG31-205 for B-vent to direct vent). The Focus manual approves B-vent installs from 0 to 2000 feet.
Source: Enviro C-14867, p. 19; C-14867, p. 15; C-14867, p. 17; C-14867, p. 32; C-13832, p. 4
What maintenance does an EG31 or Focus need?
At least once a year, have a qualified service person check that every burner port is clear and clean and that nothing blocks the pilot; the pilot flame should be blue with little or no yellow on the tips. The venting system should be examined periodically, ideally by a qualified agency. When cleaning the firebox, lift the fragile logs out, set the embers and rock wool aside, vacuum the firebox floor, clean the dust off the logs and the lint from the burner and pilot, and check the burner pan for cracking or warping. Wipe painted surfaces with a damp cloth when the insert is cool.
Source: Enviro C-14867, p. 9; C-14867, p. 10; C-14867, p. 3