Manuals & parts · Direct vent gas fireplace
Quick answer
The current Enviro G50 manuals are C-16994 (G50LI / G50LID, log set) and C-15638 (G50GI / G50GID, glass media), both free PDFs from enviro.com. Earlier G50LI fireplaces are covered by the archived C-15631 manual. The model and serial number are on the rating label on a chain under the gas valve, behind the surround.
Every G50 owner's manual Enviro lists, from the 2019 first editions to the current G50LI and G50GI manuals, with the factory parts lists, key specs and common owner questions answered from the manuals with page numbers.
Last updated · From Enviro docs C-16994 rev R03 and C-15638 rev R2 · Answers drafted from the manuals; staff review pending
G50LI
Intermittent pilot ignition (IPI) model run by the Proflame 2 remote and controller, with a log set over a front and a rear burner, a split flow valve that lets the remote shut off the rear burner, and front ember lights.
Manuals: C-16994, C-15631
G50GI
IPI model run by the Proflame 2 remote and controller. Glass media spread on an enamelled glass tray over a glass burner pan.
Manuals: C-15638
G50LID / G50GID
Dexen control-system versions, on the manual covers from the R02 (G50LI) and R2 (G50GI) revisions. The G50 manuals send D owners to the separate Dexen user manual supplied with the fireplace for remote operation, wiring, valve details, troubleshooting and replacement parts.
Manuals: C-16994, C-15638
Find your model and serial number: Remove the surround completely. The rating label and lighting instructions are on a length of chain inside the cabinet, under the gas valve. Never tamper with or remove it: it carries the model-specific serial number you need for warranty information. (Enviro C-16994, p. 6)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
G50LI Owner's Manual R03
C-16994 rev R03 · Feb 1, 2024 – Present · 60 pages · Current
G50GI Owner's Manual R2
C-15638 rev R2 · Dec 1, 2021 – Present · 56 pages · Current
Can't open a link? Enviro lists every version on its manuals pages: Enviro G50 manuals.
From the parts lists in the Enviro G50 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | G50 burner assembly | 50-3782 | Request it |
| 2 | Large ceramic marrette, set of 2 | 50-3595 | $166.62 CAD → |
| 3 | S.I.T. IPI valve | 50-2682 | $270.00 CAD → |
| 5 | PVC wire clip | 50-3614 | Request it |
| 6 | Halogen socket with wires | 50-2028 | Request it |
| 7 | Split flow valve | 50-3615 | $135.29 CAD → |
| 8 | Lower 35 W halogen bulb | 50-3291 | $15.00 CAD → |
| 9 | Convection fan only | 50-3577 | $201.82 CAD → |
| 10 | G50 safety screen | 50-3612 | Request it |
| 11 | G50 non-combustible boards, set of 2 | 50-3780 | Request it |
| 12 | Door complete | 50-3781 | Request it |
| 13 | 2 A barrel light fuse | 50-2075 | $36.32 CAD → |
| 14 | PSE IPI pilot assembly | 50-4058 | $120.00 CAD → |
| 15 | Integrated fireplace controller (IFC) | 50-3312 | Request it |
| – | Proflame 2 remote transmitter | 50-3028 | $186.54 CAD → |
| 16 | G50 slim face, black paintedoption | 50-3449 | Request it |
| – | G50 slim face, bronze powder coatoption | 50-3545 | Request it |
| – | G50 slim face, silver powder coatoption | 50-3451 | Request it |
| – | G50 slim face, nickel platedoption | 50-3574 | Request it |
| – | G50 slim face, copper platedoption | 50-3573 | Request it |
| – | G50 Forgeworks face, Midnite Bronzeoption | 50-3452 | $1,236.00 CAD → |
| 17 | Traditional log setoption | 50-3543 | $1,796.73 CAD → |
| – | Birch log setoption | 50-3542 | $2,041.09 CAD → |
| 18 | Painted black linersoption | 50-3544 | Request it |
| – | Porcelain linersoption | 50-3448 | $1,300.36 CAD → |
| – | Brown brick linersoption | 50-3412 | Request it |
| – | Herringbone linersoption | 50-3447 | Request it |
| – | Ledgestone linersoption | 50-3446 | $1,094.18 CAD → |
| – | Metallic black touch-up paint, 12 oz can | PAINT-12-MB | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Convection fan only | 50-3577 | $201.82 CAD → |
| 2 | G42/G50 glass burner pan | 50-3785 | Request it |
| 3 | S.I.T. IPI valve | 50-2682 | $270.00 CAD → |
| 4 | G50 safety screen | 50-3612 | Request it |
| 5 | PSE IPI pilot assembly |
On the rating label. Remove the surround completely; the rating label and lighting instructions are on a chain inside the cabinet, under the gas valve. Never tamper with or remove the label. It carries the model-specific serial number you need for warranty information. The location is the same on the G50LI and the G50GI.
Source: Enviro C-16994, p. 6; C-15638, p. 6
Check the model code on the rating label and match it to the manual cover. C-16994 covers the G50LI and G50LID, which have a log set over a front and a rear burner, a split flow valve and ember lights. C-15638 covers the G50GI and G50GID, which burn over glass media on an enamelled glass tray. Both are IPI fireplaces run by the Proflame 2 remote system. Earlier G50LI fireplaces are covered by the archived C-15631 manual, and earlier G50GI fireplaces by the archived R1 revision of C-15638. G50LID and G50GID owners also need the separate Dexen user manual supplied with the fireplace for remote operation. The documents list above shows the dates each manual covers.
Source: Enviro C-16994, p. 1; C-16994, p. 8; C-16994, p. 12; C-16994, p. 13; C-16994, p. 57; C-15638, p. 1; C-15638, p. 8; C-15638, p. 50; C-15638, p. 52
The G50LI and G50GI light themselves. Don't try to light the pilot by hand. Press ON/OFF on the remote; the controller beeps once, the spark lights the pilot, and the main burner lights moments later. If the pilot takes too long to light there may be air in the gas line; after too many spark attempts the system locks out for 5 minutes. If the pilot still won't light after 3 lock-out cycles, contact your gas fitter. In continuous pilot (CPI) mode the pilot stays lit after you turn the fireplace off; Enviro recommends CPI when it is below 50°F (10°C) outside, to keep the vent warm and cut condensation on the glass at start-up.
Source: Enviro C-16994, p. 7; C-16994, p. 10
Replace the three AAA batteries in the remote first; a low-battery icon shows on the remote when they are weak. If the controller (IFC) beeps when you press ON/OFF, its four AA backup batteries are low. After any battery change the system has to be initialized again: press the reset button on the IFC, wait for three beeps, then press ON on the remote. The troubleshooting table also lists the IFC on/off switch set to OFF, loose or damaged gas control wiring, a pilot that has gone out, and a lock-out (wait 5 minutes). The replacement Proflame 2 remote transmitter is part 50-3028.
Source: Enviro C-16994, p. 8; C-16994, p. 9; C-16994, p. 10; C-16994, p. 12; C-16994, p. 56; C-16994, p. 57
Yes, on the G50LI and G50GI. The Proflame 2 controller runs on 120 V AC and has a four AA battery backup for power outages. On batteries only the main burner can be controlled; auxiliary components such as the convection fan can't be used. For the Dexen G50LID and G50GID, check the separate Dexen user manual supplied with the fireplace.
Source: Enviro C-16994, p. 8; C-16994, p. 9; C-15638, p. 9
The G50 troubleshooting table lists air in the gas line (purge the line), the orange sparker wire shorting on the aluminum pilot tube, or a controller fault (check for a flashing error code and contact your dealer) when the spark won't light the pilot. If the pilot won't stay lit, it lists air in the gas line, a loose flame sensor wire, or a faulty IFC that needs replacing. After too many spark attempts the system locks out for 5 minutes; if the pilot still can't light after 3 lock-out cycles, contact your gas fitter. The G50GI manual adds a reset for locking conditions: press ON/OFF on the remote, wait about 2 seconds and press it again. Gas line and controller repairs are for a qualified service person.
Source: Enviro C-16994, p. 3; C-16994, p. 10; C-16994, p. 56; C-15638, p. 51
Condensation on a cold start is normal with all gas fireplaces and clears as the fireplace warms up. A haze from additives in the gas, or a film from the first paint cure, is also normal. After the first burn (4 hours on high without the fan), let the fireplace go cold and clean the glass; plan to clean it about two weeks after installation, then no more than two or three times a season. Clean it only when the fireplace is cold, with a mild glass cleaner and a soft cloth. Abrasive cleaners damage the glass and painted surfaces.
Source: Enviro C-16994, p. 5; C-16994, p. 15; C-16994, p. 16; C-16994, p. 17; C-16994, p. 56
Stop using the fireplace: don't run it with the glass front removed, cracked or broken. The G50 glass is a high temperature ceramic, and a damaged glass needs a factory replacement from an Enviro dealer, no substitute materials. Removal and replacement of the glass must be done by a licensed or qualified service person; the replacement glass comes with a new gasket installed. Both G50 parts lists give 50-3781 for the complete door.
Source: Enviro C-16994, p. 3; C-16994, p. 15; C-16994, p. 57; C-15638, p. 52
Yes, with the conversion kit, installed by a qualified service agency only. For the G50LI the kit has an LP stepper motor with hardware, two burner orifices (LP front #53, rear #52), a pilot orifice and three conversion labels. For the G50GI the kit lists one burner orifice (LP #47), a pilot orifice and the labels, with the stepper motor sold separately. The installer swaps the burner and pilot orifices and the valve's stepper motor, leak-tests the connections with soapy water, checks the inlet and manifold pressures with a manometer and fits the conversion labels on or close to the rating label.
Source: Enviro C-16994, p. 20; C-16994, p. 21; C-15638, p. 18
Have the fireplace inspected before first use and at least once a year by a qualified service person; more frequent cleaning may be needed if there is a lot of lint from carpets or bedding. The yearly check covers the burner ports (clear and clean) and the pilot (not blocked, with a blue flame and little or no yellow tips). The venting system should be inspected for blockage and deterioration, preferably by a qualified agency. When the firebox is cleaned, the logs are removed carefully (they are fragile), the firebox floor is vacuumed and the burner tube is checked for cracking or severe warping; a small amount of soot on the bottom of the logs is normal.
Source: Enviro C-16994, p. 3; C-16994, p. 15

Sale price $15.00 CAD Regular price $16.99 CAD
| 50-4058 |
| $120.00 CAD → |
| 6 | G50 door complete | 50-3781 | Request it |
| 7 | G50 non-combustible boards, set of 2 | 50-3780 | Request it |
| 8 | G50 enamelled glass tray | 50-3784 | Request it |
| 9 | Integrated fireplace controller (IFC) | 50-3312 | Request it |
| 10 | Proflame 2 remote transmitter | 50-3028 | $186.54 CAD → |
| 11 | G50 porcelain linersoption | 50-3448 | $1,300.36 CAD → |
| 12 | G50 slim face, black paintedoption | 50-3449 | Request it |
| – | G50 slim face, grey powder coatoption | 50-3450 | Request it |
| – | G50 slim face, bronze powder coatoption | 50-3545 | Request it |
| – | G50 slim face, silver powder coatoption | 50-3451 | Request it |
| – | G50 slim face, nickel platedoption | 50-3574 | Request it |
| – | G50 slim face, copper platedoption | 50-3573 | Request it |
| – | G50 Forgeworks face, Midnite Bronzeoption | 50-3452 | $1,236.00 CAD → |
| – | G42/G50 driftwood log setoption | 50-3611 | $941.45 CAD → |
| – | Metallic black touch-up paint, 12 oz can | PAINT-12-MB | Request it |