Where is the serial number on an Enviro Ascot?
On the rating label, which is on a plate hanging at the back left of the stove. The label also shows the type of gas the stove is set up for. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-13825, p. 5; C-13825, p. 1; C-13825, p. 40
Which Ascot manual do I need?
The Ascot is discontinued and Enviro lists every Ascot manual as archived. Use C-13825, the last edition, for any Ascot: it has the lighting, maintenance and conversion instructions and the parts lists on pages 35 to 37. Older stoves may match an earlier edition by date: C-12589 (2012), C-10789 (2005), C-10237 (2004) or C-10134 (2003). The 2003 to 2005 manuals list separate natural gas and propane valves (EC-006 and EC-007) where the 2012 manuals list one convertible valve, 50-1421.
Source: Enviro C-13825, p. 3; C-13825, p. 35; C-13825, p. 37; C-10789, p. 28
How do I light the pilot on an Ascot?
The Ascot has a millivolt valve with a pilot you light by hand, following the lighting label. Use only your hand on the gas control knob: if it will not push in or turn by hand, don't force it and call a qualified service technician. The valve has a lockout, so the pilot cannot be relit until the thermocouple has cooled; if the knob does not pop up when released, stop and call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the knob to OFF and call them.
- Turn off all electrical power to the stove and turn the gas control knob clockwise to OFF. (C-13825, p. 6)
- Open the door and wait five minutes to clear out any gas, then close it. If you smell gas, including near the floor, stop and follow the safety instructions on the label. (C-13825, p. 6)
- Find the pilot, to the right behind the side log. Turn the gas control knob counter-clockwise to PILOT, push it in fully and hold it. (C-13825, p. 6)
- While holding the knob in, press the ignitor several times until the pilot lights. Check that the flame engulfs the thermocouple. (C-13825, p. 7)
- Keep the knob pressed in for about 30 seconds after the pilot lights, then release it. If the pilot goes out, start again from the five minute wait. (C-13825, p. 6)
- Turn the knob counter-clockwise to ON, flip the burner switch to ON, set the HI/LOW knob, then turn the electrical power back on. (C-13825, p. 6)
Source: Enviro C-13825, p. 6; C-13825, p. 7
My Ascot won't spark when I try to light it. What should I check?
Start with the AA battery in the electronic ignition module, which sits at the far left behind the valve cover. If there is still no spark, Enviro's troubleshooting table points to the ignitor connections and the spark electrode (a broken ceramic insulator, or an electrode that is not arcing to the pilot). The parts list gives the electronic ignition module as 50-589 and the spark electrode with ignitor cable as EC-011.
- Find the ignition module at the far left, behind the valve cover. (C-13825, p. 8)
- Remove the battery cover on the left side of the module and replace the AA battery. (C-13825, p. 8)
- Refit the battery cover and check for spark by pressing the pilot knob on the control panel. (C-13825, p. 8)
Source: Enviro C-13825, p. 8; C-13825, p. 34; C-13825, p. 35; C-13825, p. 36
Why won't the pilot on my Ascot stay lit?
Enviro's troubleshooting table lists two causes. A thermocouple problem: check the thermocouple is fully tightened into the back of the valve, that the pilot flame fully surrounds it (if the flame is small, check gas pressure, the pilot rate screw and the pilot head), and that it gives more than 5 mV at the valve; if not, replace the thermocouple. Or air in the gas line, if the pilot dies while you hold the knob in: the line needs bleeding and the gas pressure checked, so contact your dealer. If the pilot or burners go out on their own, open the glass door and wait 5 minutes before you relight.
Source: Enviro C-13825, p. 34; C-13825, p. 2
The Ascot pilot is lit but the burner won't come on. Why?
Check that the gas control knob is turned to ON, not PILOT, and that the burner switch is on. If a thermostat or remote runs the stove, make sure it is calling for heat (set it several degrees above room temperature) and that the ON/OFF switch on the control panel is in the remote/thermostat position. If the burner still won't light, the troubleshooting table moves on to voltmeter checks of the valve, the thermopile and the thermostat wiring, which is repair work for a qualified service person.
Source: Enviro C-13825, p. 34; C-13825, p. 7; C-13825, p. 6; C-13825, p. 2
How do I clean the glass on an Ascot?
Clean the glass only when the stove has cooled. Condensation on a cold start is normal, and the first paint cure can leave a light film, so clean the glass after the first 4 hours of use and again about two weeks after installation; after that it should need cleaning no more than two or three times a season. Use a mild glass cleaner and a soft cloth: abrasive cleaners damage the glass and enamel.
- Turn the stove off and wait until it has cooled down. (C-13825, p. 9)
- Lift the cast iron top straight up off the stove. (C-13825, p. 9)
- Lift the two door handles on either side of the door and lift the glass door assembly straight up and out. (C-13825, p. 9)
- Check that the gasket on the back of the glass is attached and intact. (C-13825, p. 8)
- Clean the glass with a mild glass cleaner and a soft cloth. (C-13825, p. 8)
- Refit the door and make sure it is properly fastened before you relight the stove. (C-13825, p. 9)
Source: Enviro C-13825, p. 8; C-13825, p. 9
The Ascot glass is cracked. What do I need?
Stop using the stove: Enviro says never to run it with the glass removed, cracked or broken. The glass is a high temperature ceramic, and only a factory replacement bought from an Enviro dealer may be used; no substitute materials are allowed. Removing and replacing the glass must be done by a licensed or qualified service person. The parts list gives the glass with gasket as 50-715.
Source: Enviro C-13825, p. 9; C-13825, p. 36
Can I convert an Ascot from natural gas to propane?
Yes, with a conversion kit installed by a qualified service agency only. On the convertible S.I.T. valve the kit changes the main burner orifice (#48 DMS natural gas, #57 DMS propane) and the pilot injector (0.62 mm natural gas, 0.35 mm propane), and the valve's conversion screw is flipped so its red O-ring shows for propane. The installer leak-tests, relights the burner on HI and LO, and fits the conversion label on or near the rating label. The parts list gives 50-1443 for natural gas to propane and 50-1442 for propane to natural gas.
Source: Enviro C-13825, p. 10; C-13825, p. 11; C-13825, p. 36
What maintenance does an Ascot need?
Enviro says the stove should be inspected before first use and at least once a year by a qualified service person, and the venting system checked for blockage and deterioration, preferably by a qualified agency. Once a year, check that all the burner ports are clear and the pilot is not blocked; the pilot flame should be blue with little or no yellow at the tips. Keep the control compartment, burner and air passages clean; lint from carpets or bedding can mean more frequent cleaning. To clean the firebox, follow the steps below.
- With the stove cold, take out the logs carefully (they are fragile), then lift the embers and rock wool onto a paper towel. (C-13825, p. 8)
- Vacuum the bottom of the firebox, dust the logs and remove any lint from the burner and pilot. (C-13825, p. 8)
- Look at the burner pan for cracking or severe warping and the logs for deterioration or heavy soot; contact your dealer if you see a problem. (C-13825, p. 8)
- Put the logs and embers back as shown in the log set section, leaving the embers loose and away from the pilot. (C-13825, p. 32)
Source: Enviro C-13825, p. 8; C-13825, p. 2
Does the Ascot work in a power outage?
Yes. The Ascot has a millivolt gas control that runs on electricity made by the pilot flame, so the stove operates without household power. Only the optional blower needs power; it has a three-prong grounded plug and must go into a properly grounded outlet.
Source: Enviro C-13825, p. 30
How does the optional blower on an Ascot work?
The blower comes on by itself once the stove is up to temperature, about 20 minutes. Turn the fan control knob to change the speed, and counter-clockwise until it clicks to turn it off. Enviro advises not running it below 1/3 speed, which strains the motor windings and can cause early fan failure. The fan kit is 30-056 in the parts list.
Source: Enviro C-13825, p. 7; C-13825, p. 35