Enviro Parts Only / One brand, every part
Search by Model / Find your exact unit
14-Day Returns / See our returns policy
Expert Advice / From people who care
Enviro Fireplace PartsEvery Enviro part, the right fit.
SupportWe're here to helpTrack OrderCheck status
Find My PartFind the right fit
  • Models
  • Find My Part
  • Manuals
  • Contact
Menu
  • Models
  • Find My Part
  • Manuals
  • Contact
Enviro Fireplace PartsEvery Enviro part, the right fit.
Find My Part Request a Part
Enviro Fireplace Parts

Every Enviro part, the right fit.

Get fitment tips, restock alerts, and Enviro parts news — straight to your inbox.

Shop

  • Shop by Model
  • Shop by Category
  • All Parts

Parts by Appliance

  • Wood Stove Parts
  • Gas Fireplace Parts
  • Pellet Stove Parts

Help & Support

  • Find My Part
  • Request a Part
  • Help Centre
  • Shipping & Delivery
  • Returns & Refunds
  • Warranty

Company

  • About Us
  • Contact Us
  • Blog

© 2026 Enviro Fireplace Parts. All rights reserved.

Enviro Fireplace Parts is operated by Friendly Fires Inc. · (705) 741-1900

PrivacyTermsAccessibility
  • Home
  • Models
  • Parts
  • Support
  • Cart
  1. Home
  2. Manuals
  3. Enviro Sienna

Manuals & parts · Gas fireplace insert, direct vent or B-vent (discontinued)

Enviro Sienna Manuals

Quick answer

The Enviro Sienna is a discontinued gas fireplace insert, made in direct vent and B-vent versions, and Enviro lists all five of its owner's manuals as archived. The latest is C-13833, dated January 22, 2013, a free PDF from enviro.com; inserts from 2004 to 2006 match the first edition, C-10637. Sienna parts are still sold here, and the rating label is under the control panel on a metal plate chained to the fireplace.

Every Sienna owner's manual Enviro still publishes, the factory parts and options lists with part numbers, key specs, and answers to common Sienna questions about lighting, the B-vent spill switch, the glass, the logs and fuel conversion, each taken from the official Enviro manual with the page number. Enviro's manuals page files the Sienna under the family code EG41_FPI; the manuals themselves call it the Sienna. Enviro no longer makes the Sienna, but we still sell its parts.

Last updated Nov 25, 2026 · From Enviro docs C-13833, C-10637 and C-11075 · Answers drafted from the manuals; staff review pending

Shop Enviro Sienna parts

Which Enviro Sienna do I have?

Sienna DV (direct vent)

Insert vented with two 3 inch aluminum or stainless steel flex liners into a co-linear to co-axial adaptor and a vertical termination cap; vertical venting only. Natural gas or propane.

Manuals: C-13833, C-11535, C-11212, C-11075, C-10637

Sienna BV (B-vent)

Insert that draws combustion air from the room and vents through a 4 inch flex liner or Type B gas vent, with a manual reset spill switch at the rear. A direct vent Sienna can be converted to B-vent with the B-vent connector assembly.

Manuals: C-13833, C-11535, C-11212, C-11075, C-10637

Sienna, 2006 and later (convertible valve)

From the March 2006 manual on, the Sienna uses the convertible S.I.T. Nova valve (50-1421), converted between natural gas and propane by flipping a screw in the valve.

Manuals: C-13833, C-11535, C-11212, C-11075

Sienna, 2004 to 2006 (separate NG and LP valves)

The first edition lists separate S.I.T. Nova valves for natural gas (EC-006) and propane (EC-007), with 50% turn down, and conversion kits that swap the HI/LO regulator.

Manuals: C-10637

Find your model and serial number: The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the fireplace. (Enviro C-13833, p. 5)

Enviro Sienna parts from the manual, sold here

Enviro Ceramic Fan Sensor (EC-001) — Enviro Fireplace Parts

Enviro Ceramic Fan Sensor (EC-001)

Sale price $77.79 CAD Regular price $85.99 CAD

Enviro Westport EC-011 Spark Electrode — Enviro Fireplace Parts

Enviro Spark Electrode (EC-011)

Sale price $72.73 CAD Regular price $80.99 CAD

Enviro EC-012 Thermopile — Enviro Fireplace Parts

Enviro Thermopile - Most Models (EC-012)

Sale price $88.33 CAD Regular price $97.99 CAD

Enviro Pilot Orifice (Injector) - Natural Gas, Threaded (Post Oct 2000) (EC-019) — Enviro Fireplace Parts
Get the manual
Diagram of an Enviro Sienna showing where the rating label with the model and serial number is: On the Enviro Sienna the rating label is under the control panel, on a rectangular metal plate chained to the fireplace.
Where to find the Enviro Sienna rating label. Our diagram, based on Enviro C-13833 p. 5.
Chart of Enviro Sienna versions: Sienna DV (direct vent), Sienna BV (B-vent), Sienna, 2006 and later (convertible valve), Sienna, 2004 to 2006 (separate NG and LP valves), with what sets each one apart.
Enviro Sienna versions at a glance. Our chart, from the Enviro manuals listed below.

Enviro Sienna owner's and installation manuals

Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.

The Enviro Sienna is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro Sienna parts.

Archived Enviro Sienna manuals (5)
  • Sienna Owner's Manual

    C-13833 · Jan 22, 2013 – Present

    PDF
  • Sienna Owner's Manual

    C-11535 · Mar 14, 2008 – Jan 22, 2013

    PDF
  • Sienna Owner's Manual

    C-11212 · Feb 19, 2007 – Mar 14, 2008

    PDF
  • Sienna Owner's Manual

    C-11075 · Mar 20, 2006 – Feb 19, 2007

    PDF
  • Sienna Owner's Manual

    C-10637 · Nov 5, 2004 – Mar 20, 2006

    PDF

Can't open a link? Enviro lists every version on its manuals pages: Enviro Sienna manuals, Enviro legacy manuals.

Enviro Sienna parts list, with part numbers

From the parts lists in the Enviro Sienna manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.

Sienna unit components (Enviro C-13833, p. 27)

RefPartPart #Our store
1Ceramic fan temperature sensor, 120°FEC-001$77.79 CAD →
2Manual reset spill switch, 300°F (149°C), normally closedEC-003Request it
3S.I.T. Nova valve, convertible50-1421Request it
4ThermocoupleEC-009Request it
4Spark electrode with ignitor cableEC-011$72.73 CAD →
4ThermopileEC-012$88.33 CAD →
4Pilot orifice, NG, threadedEC-019$61.62 CAD →
4Pilot orifice, LP, threadedEC-020$72.00 CAD →
5Pilot gasketEC-021$24.44 CAD →
6S.I.T. piezo ignitorEC-023$44.25 CAD →
7Burner switchEC-026$30.00 CAD →
8Fan controller, 115 VEC-039Request it
9Domestic power cord, 115 VEC-042$55.38 CAD →
10Convection blower, 115 VEC-069$293.33 CAD →
–SIT pilot ⅛" tube with end ferrules (1 piece)30-043$59.75 CAD →
11Blank orifice #7350-343$35.47 CAD →
–Embers50-491Request it
–On/off remote control kitoption50-559Request it
–Programmable wall mounted remote controloption50-583Request it
12Dual bulb door gasket (10 feet)50-634$68.00 CAD →
13Grate50-916Request it
14Three flame pilot hood50-925$9.00 CAD →
15Burner50-1089Request it
16DV flue connector50-1090Request it
17Relief door gasket50-1091Request it
18Brick panels (set of 4)50-1092Request it
19Log support50-1093Request it
–Sienna owner's manual50-1096Request it
20Door, glass and gasket50-1112Request it
21Log set with embers50-1114Request it
22Burner tray complete50-1115Request it
23Air intake covers50-1116Request it
24BV vent connector50-1117Request it
–Conversion kit, LP to NG, convertible50-1440Request it
–Conversion kit, NG to LP, convertible50-1441$109.55 CAD →
–S.I.T. valve conversion screw with o-ring50-1450Request it
–S.I.T. valve conversion screw cap50-1451Request it
–Pan burner only50-1459Request it
–Control panel decal50-1539Request it

Sienna faces, surrounds and trim (options) (Enviro C-13833, p. 30)

RefPartPart #Our store
1AThe Cottage trim kit, goldoption50-548Request it
1AThe Cottage trim kit, pewteroption50-549Request it
1AThe Cottage trim kit, antique copperoption50-550Request it

Sienna 2004 to 2006 (first edition), differences (Enviro C-10637, p. 25)

RefPartPart #Our store
3S.I.T. Nova valve, NG (50% turn down)EC-006Request it
3S.I.T. Nova valve, LP (50% turn down)EC-007Request it
–Conversion kit, LP to NG50-1118Request it

Enviro Sienna questions, answered from the manual

Where is the serial number on an Enviro Sienna?

On the rating label, which is under the control panel, attached to a rectangular metal sheet that is chained to the fireplace. Your installer should also have recorded the model, the serial number and whether it is direct vent or B-vent on the installation data sheet at the back of the owner's manual.

Source: Enviro C-13833, p. 5; C-13833, p. 33

Which Sienna manual do I need?

The Sienna is discontinued and Enviro lists all five of its owner's manuals as archived; each covers both the direct vent and the B-vent version. Pick the edition whose dates match your installation. C-13833, dated January 22, 2013, is the latest; C-11535, C-11212 and C-11075 cover 2006 to 2013 and list the same convertible Nova valve, 50-1421. The first edition, C-10637 (November 5, 2004 to March 20, 2006), lists separate natural gas and propane valves (EC-006 and EC-007) and different conversion kits. Enviro's manuals page files them under the family code EG41_FPI.

Source: Enviro C-13833, p. 4; C-13833, p. 27; C-13833, p. 33; C-11075, p. 26; C-10637, p. 25

How do I light the pilot on an Enviro Sienna?

The Sienna has a standing pilot that you light by hand at the control panel. The gas valve has a lockout device, so the pilot cannot be relit until the thermocouple has cooled. If the knob does not pop up when released, stop and call your service technician or gas supplier; if the pilot will not stay lit after several tries, turn the gas control knob to OFF and call them. To turn the flames off, flip the burner switch to OFF; for the season or for servicing, also turn the gas shut-off valve to OFF.

  1. Turn off all electrical power to the fireplace, then turn the gas control knob clockwise to OFF. (C-13833, p. 7)
  2. Open the door and wait five minutes to clear out any gas, then close it and smell for gas, including next to the floor. If you smell gas, stop and follow the safety information on the lighting label. (C-13833, p. 7)
  3. Find the pilot, to the left under the front log. Turn the gas control knob counter-clockwise to PILOT, push it in fully and hold it while you light the pilot with the ignitor button on the control panel. (C-13833, p. 7)
  4. Keep the knob pushed in for about 30 seconds after the pilot is lit, then release it. If the pilot goes out, repeat from the five-minute wait. (C-13833, p. 7)
  5. Turn the gas control knob counter-clockwise to ON, flip the burner switch to ON, set the HI/LOW knob and turn the electrical power back on. Check that all the burner holes are lit. (C-13833, p. 7)

Source: Enviro C-13833, p. 7; C-13833, p. 8

Can I use a remote with the Sienna, and why won't it work?

Yes. The Sienna can use an optional remote control or an optional cordless wall thermostat; the parts list has an on/off remote control kit, 50-559, and a programmable wall mounted remote control, 50-583. If you use one most of the time, leave the ON/OFF switch on the control panel in the remote/thermostat position. If the remote stops working, check its batteries, then check that the switch is not turned to OFF, the gas control valve is not at PILOT or OFF, and the pilot has not gone out.

Source: Enviro C-13833, p. 7; C-13833, p. 26; C-13833, p. 27

Why won't my Sienna pilot or burner stay lit?

Enviro's troubleshooting table gives these checks. If the pilot will not stay lit: the thermocouple must be tight at the rear of the valve, the pilot flame must fully surround it, and it must read more than 5 mV at the valve, or it should be replaced; if the pilot dies while you hold the knob in, there may be air in the gas line, so bleed the line and check the gas pressure. If the burners will not stay lit: check the gas line pressure, the flame on the thermopile (at least 300 mV with the burner switched on) and the thermostat wiring, and on a B-vent Sienna check for spillage at the draft hood that may trip the spill switch. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Source: Enviro C-13833, p. 26; C-13833, p. 2

My B-vent Sienna keeps shutting off. Is it the spill switch?

It may be. The B-vent Sienna has a vent safety shutoff, a 300°F (149°C) manual reset spill switch (EC-003) on the rear of the appliance, that protects against improper venting of combustion products. If it trips more than once, have a qualified service technician inspect the venting for blockage or severe down draft. Draft can be checked with smoke at the ¼" tube at the front of the unit: suction into the tube means it is drafting properly, while air blowing out must be corrected before the unit is started. An air tight house or a vacuum in the room from another air-moving device can also starve it of combustion air; supply make up air to the unit.

Source: Enviro C-13833, p. 14; C-13833, p. 20; C-13833, p. 26; C-13833, p. 27

How do I break in a new Sienna and clean the glass?

On first use, run the Sienna on high with the fan off for two to four hours (the approvals page says the first 4 hours) to cure the paint, logs and gasket, with a door or window open because it will smoke. Then turn it off, including the pilot, let it go completely cold and clean the glass with a gas fireplace glass cleaner. Clean the glass again about two weeks after the first burn, then no more than two or three times a season, with a mild glass cleaner and a soft cloth, never when hot; abrasive cleaners damage the glass. Condensation on a cold start is normal, and gas additives can make the glass hazy. The glass door comes off by removing two 5/16" bolts at the top outside corners of the glass frame, a step the manual places under qualified installers.

Source: Enviro C-13833, p. 8; C-13833, p. 4; C-13833, p. 9; C-13833, p. 10; C-13833, p. 26

The Sienna glass is cracked. What do I need?

Do not run the fireplace with the glass removed, cracked or broken; replacing the glass must be done by a licensed or qualified service person. The glass is a high temperature ceramic and needs a factory replacement from an Enviro dealer, with no substitute materials. The parts list has the door, glass and gasket as one part, 50-1112, and the dual bulb door gasket (10 feet), 50-634. A damaged glass door being transported must be wrapped in newsprint and tape or a strong plastic bag; wear gloves when handling it.

Source: Enviro C-13833, p. 9; C-13833, p. 27

Can I convert a Sienna from natural gas to propane?

Yes, with a conversion kit installed by a qualified service agency only. On Siennas with the convertible Nova valve, 50-1421, the kits are NG to LP 50-1441 and LP to NG 50-1440; each holds a burner orifice (NG #32 DMS or LP #49 DMS), a pilot injector (NG 0.62 mm or LP 0.35 mm), an instruction sheet and a conversion label, and the service agency flips the conversion screw in the valve. Early Siennas with separate natural gas and propane valves (EC-006 and EC-007) use kits 50-1119 (NG to LP) and 50-1118 (LP to NG), which replace the 50% turn down HI/LO regulator on the valve. The conversion label goes on or close to the rating label.

Source: Enviro C-13833, p. 11; C-13833, p. 12; C-13833, p. 27; C-10637, p. 10; C-10637, p. 25

How does the Sienna fan work?

The convection blower is thermostatically controlled: it comes on only when the fireplace is up to temperature, about 20 minutes after lighting, and turns off after the fireplace has cooled. Turn the fan control knob to change the speed, and counter-clockwise until it clicks to turn it off. Enviro advises not running the blower below 1/3 speed, which strains the windings and can cause premature fan failure. The fan plugs into a grounded three-prong outlet. Replacement parts include the convection blower, 115 V, EC-069, the fan controller EC-039 and the 120°F ceramic fan temperature sensor EC-001.

Source: Enviro C-13833, p. 8; C-13833, p. 18; C-13833, p. 27

How do I clean the Sienna firebox and put the logs back?

At least once a year check that the burner ports are clear, that nothing blocks the pilot and that the pilot flame is blue with little or no yellow; have the venting examined by a qualified agency. The logs are fragile, and only the ember material supplied with the fireplace may be used on the burner. When lighting for the first time after replacing the logs and embers, watch for ignition at all the burner ports; if there is a long delay, turn it off, let it cool and rearrange the embers.

  1. With the fireplace cool and the glass door off, remove the logs carefully and lift the embers and rock wool out onto a paper towel. (C-13833, p. 9)
  2. Vacuum the bottom of the firebox, clean the dust off the logs and remove any lint from the burner and pilot. Check the burner pan for cracking or severe warping and the logs for heavy soot; a little soot under the logs is normal. (C-13833, p. 9)
  3. Lean the back log against the back of the firebox, pushed back as far as it goes. Set the left and right logs with their two holes over their locator pins. Rest the bottom of the left/center log over the locator pin on the burner and against the grate, with its top against the knot on the back log. (C-13833, p. 22)
  4. Rest the notch in the front of the right/center log around the right/center grate post, with its back end on the burner tray. Keep every burner port clear. (C-13833, p. 23)
  5. Place the rock wool loosely in front of the burner and the embers irregularly on and around the front of the burner. Do not pack them and keep them off the pilot assembly. (C-13833, p. 23)

Source: Enviro C-13833, p. 9; C-13833, p. 22; C-13833, p. 23; C-13833, p. 24

How do I take the Sienna surround off?

The Sienna must always have one of its panels around it: the unit panel, the filler panel or the filler panel with trim. The surround hangs on four hooks, and draft relief openings must not be covered or blocked. Wipe the surround with a damp cloth periodically, never when hot; plated finishes stain from fingerprints.

  1. Lift the surround straight up to unhook the notches on its hooks from the bottom of the slots. (C-13833, p. 21)
  2. Pull the surround out away from the fireplace and set it where it will not be damaged. (C-13833, p. 21)
  3. To refit it, hold it upright with the four hooks toward the fireplace and slide them all the way into their slots, with the notch on each hook at the bottom of its slot. (C-13833, p. 21)

Source: Enviro C-13833, p. 21; C-13833, p. 9

Key specs

Gas input
23,000 to 41,000 BTU/hr natural gas; 21,000 to 41,000 BTU/hr propane (C-13833, p. 19)
Manifold pressure
3.8" W.C. (min. 1.2") natural gas; 11.0" W.C. (min. 2.7") propane (C-13833, p. 19)
Supply pressure
5.0" to 7.0" W.C. natural gas; 12.0" to 13.0" W.C. propane (C-13833, p. 19)
Main burner orifice and venturi
#32 DMS natural gas, venturi ½" min.; #49 DMS propane, venturi ⅞" min. (C-13833, p. 19)
Gas connection
Certified flexible pipe on the right side, ending in a ⅜" male NPT fitting (C-13833, p. 19)
Minimum fireplace opening
35" wide at the front, 23 ¼" at the back; 23 ¾" high (23" with trim); 18" deep DV, 19" BV (16 ½" / 17 ½" with trim) (C-13833, p. 14)
Chimney flue size
7" x 7" direct vent, 5" x 5" B-vent (C-13833, p. 14)
Venting, direct vent
Two 3" aluminum or stainless steel flex liners, co-linear to co-axial adaptor, vertical termination cap; 35 ft (10.67 m) maximum height (C-13833, p. 16)
Venting, B-vent
4" aluminum or stainless steel flex vent and/or certified Type B gas vent (C-13833, p. 14)
Mantel and hearth
2" mantel at 39" min., 10" mantel at 43" min. above the bottom of the unit; 16" of non-combustible floor protection in front at floor level (C-13833, p. 13)

Need a part for your Enviro Sienna?

15 of 53 parts-list items are sold here.

Shop Enviro Sienna partsNot sure which part? Find my part

Gas work, venting, electrical and glass replacement must be done by a qualified installer or service agency. These answers summarize Enviro's manuals; the manual for your exact model and serial number is the authority.

Enviro Pilot Orifice (Injector) - Natural Gas, Threaded (Post Oct 2000) (EC-019)

Sale price $61.62 CAD Regular price $67.99 CAD

Enviro Threaded Pilot Injector - LP (EC-020) — Enviro Fireplace Parts

Enviro Threaded Pilot Injector - LP (EC-020)

Sale price $72.00 CAD Regular price $79.99 CAD

Enviro Pilot Gasket Part # EC-021 — Enviro Fireplace Parts

Enviro Pilot Gasket E30/EG31/Q1/Q3/S20/Westport (EC-021)

Sale price $24.44 CAD Regular price $26.99 CAD

Enviro EC-023 Westport Piezo Igniter — Enviro Fireplace Parts

Enviro Piezo Spark Ignitor - Many Fireplace Models (EC-023)

Sale price $44.25 CAD Regular price $50.00 CAD

Enviro Insert EC-026 Fan Switch — Enviro Fireplace Parts

Enviro Burner / Rocker Switch - Many Models (EC-026)

Sale price $30.00 CAD Regular price $33.99 CAD

See all Enviro Sienna parts →
1AThe Cottage trim kit, painted blackoption50-694Request it
2ACape Cod doorsoption50-1097Request it
3AUnit panel and keystoneoption50-1108Request it
4ACottageoption50-1109Request it
5AFiller paneloption50-1110Request it
6ALouvers (set of 2)option50-1111Request it
7APanel trim set, 46" x 30" (117 cm x 76 cm), blackoption50-1113Request it
–
Conversion kit, NG to LP
50-1119
Request it
, and 7 parts are tagged to fit the Enviro Sienna