Manuals & parts · Gas fireplace insert, direct vent or B-vent (discontinued)
Quick answer
The Enviro Sienna is a discontinued gas fireplace insert, made in direct vent and B-vent versions, and Enviro lists all five of its owner's manuals as archived. The latest is C-13833, dated January 22, 2013, a free PDF from enviro.com; inserts from 2004 to 2006 match the first edition, C-10637. Sienna parts are still sold here, and the rating label is under the control panel on a metal plate chained to the fireplace.
Every Sienna owner's manual Enviro still publishes, the factory parts and options lists with part numbers, key specs, and answers to common Sienna questions about lighting, the B-vent spill switch, the glass, the logs and fuel conversion, each taken from the official Enviro manual with the page number. Enviro's manuals page files the Sienna under the family code EG41_FPI; the manuals themselves call it the Sienna. Enviro no longer makes the Sienna, but we still sell its parts.
Last updated · From Enviro docs C-13833, C-10637 and C-11075 · Answers drafted from the manuals; staff review pending
Sienna DV (direct vent)
Insert vented with two 3 inch aluminum or stainless steel flex liners into a co-linear to co-axial adaptor and a vertical termination cap; vertical venting only. Natural gas or propane.
Manuals: C-13833, C-11535, C-11212, C-11075, C-10637
Sienna BV (B-vent)
Insert that draws combustion air from the room and vents through a 4 inch flex liner or Type B gas vent, with a manual reset spill switch at the rear. A direct vent Sienna can be converted to B-vent with the B-vent connector assembly.
Manuals: C-13833, C-11535, C-11212, C-11075, C-10637
Sienna, 2006 and later (convertible valve)
From the March 2006 manual on, the Sienna uses the convertible S.I.T. Nova valve (50-1421), converted between natural gas and propane by flipping a screw in the valve.
Manuals: C-13833, C-11535, C-11212, C-11075
Sienna, 2004 to 2006 (separate NG and LP valves)
The first edition lists separate S.I.T. Nova valves for natural gas (EC-006) and propane (EC-007), with 50% turn down, and conversion kits that swap the HI/LO regulator.
Manuals: C-10637
Find your model and serial number: The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the fireplace. (Enviro C-13833, p. 5)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro Sienna is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro Sienna parts.
Sienna Owner's Manual
C-13833 · Jan 22, 2013 – Present
Sienna Owner's Manual
C-11535 · Mar 14, 2008 – Jan 22, 2013
Sienna Owner's Manual
C-11212 · Feb 19, 2007 – Mar 14, 2008
Sienna Owner's Manual
C-11075 · Mar 20, 2006 – Feb 19, 2007
Sienna Owner's Manual
C-10637 · Nov 5, 2004 – Mar 20, 2006
Can't open a link? Enviro lists every version on its manuals pages: Enviro Sienna manuals, Enviro legacy manuals.
From the parts lists in the Enviro Sienna manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Ceramic fan temperature sensor, 120°F | EC-001 | $77.79 CAD → |
| 2 | Manual reset spill switch, 300°F (149°C), normally closed | EC-003 | Request it |
| 3 | S.I.T. Nova valve, convertible | 50-1421 | Request it |
| 4 | Thermocouple | EC-009 | Request it |
| 4 | Spark electrode with ignitor cable | EC-011 | $72.73 CAD → |
| 4 | Thermopile | EC-012 | $88.33 CAD → |
| 4 | Pilot orifice, NG, threaded | EC-019 | $61.62 CAD → |
| 4 | Pilot orifice, LP, threaded | EC-020 | $72.00 CAD → |
| 5 | Pilot gasket | EC-021 | $24.44 CAD → |
| 6 | S.I.T. piezo ignitor | EC-023 | $44.25 CAD → |
| 7 | Burner switch | EC-026 | $30.00 CAD → |
| 8 | Fan controller, 115 V | EC-039 | Request it |
| 9 | Domestic power cord, 115 V | EC-042 | $55.38 CAD → |
| 10 | Convection blower, 115 V | EC-069 | $293.33 CAD → |
| – | SIT pilot ⅛" tube with end ferrules (1 piece) | 30-043 | $59.75 CAD → |
| 11 | Blank orifice #73 | 50-343 | $35.47 CAD → |
| – | Embers | 50-491 | Request it |
| – | On/off remote control kitoption | 50-559 | Request it |
| – | Programmable wall mounted remote controloption | 50-583 | Request it |
| 12 | Dual bulb door gasket (10 feet) | 50-634 | $68.00 CAD → |
| 13 | Grate | 50-916 | Request it |
| 14 | Three flame pilot hood | 50-925 | $9.00 CAD → |
| 15 | Burner | 50-1089 | Request it |
| 16 | DV flue connector | 50-1090 | Request it |
| 17 | Relief door gasket | 50-1091 | Request it |
| 18 | Brick panels (set of 4) | 50-1092 | Request it |
| 19 | Log support | 50-1093 | Request it |
| – | Sienna owner's manual | 50-1096 | Request it |
| 20 | Door, glass and gasket | 50-1112 | Request it |
| 21 | Log set with embers | 50-1114 | Request it |
| 22 | Burner tray complete | 50-1115 | Request it |
| 23 | Air intake covers | 50-1116 | Request it |
| 24 | BV vent connector | 50-1117 | Request it |
| – | Conversion kit, LP to NG, convertible | 50-1440 | Request it |
| – | Conversion kit, NG to LP, convertible | 50-1441 | $109.55 CAD → |
| – | S.I.T. valve conversion screw with o-ring | 50-1450 | Request it |
| – | S.I.T. valve conversion screw cap | 50-1451 | Request it |
| – | Pan burner only | 50-1459 | Request it |
| – | Control panel decal | 50-1539 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1A | The Cottage trim kit, goldoption | 50-548 | Request it |
| 1A | The Cottage trim kit, pewteroption | 50-549 | Request it |
| 1A | The Cottage trim kit, antique copperoption | 50-550 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 3 | S.I.T. Nova valve, NG (50% turn down) | EC-006 | Request it |
| 3 | S.I.T. Nova valve, LP (50% turn down) | EC-007 | Request it |
| – | Conversion kit, LP to NG | 50-1118 | Request it |
On the rating label, which is under the control panel, attached to a rectangular metal sheet that is chained to the fireplace. Your installer should also have recorded the model, the serial number and whether it is direct vent or B-vent on the installation data sheet at the back of the owner's manual.
Source: Enviro C-13833, p. 5; C-13833, p. 33
The Sienna is discontinued and Enviro lists all five of its owner's manuals as archived; each covers both the direct vent and the B-vent version. Pick the edition whose dates match your installation. C-13833, dated January 22, 2013, is the latest; C-11535, C-11212 and C-11075 cover 2006 to 2013 and list the same convertible Nova valve, 50-1421. The first edition, C-10637 (November 5, 2004 to March 20, 2006), lists separate natural gas and propane valves (EC-006 and EC-007) and different conversion kits. Enviro's manuals page files them under the family code EG41_FPI.
Source: Enviro C-13833, p. 4; C-13833, p. 27; C-13833, p. 33; C-11075, p. 26; C-10637, p. 25
The Sienna has a standing pilot that you light by hand at the control panel. The gas valve has a lockout device, so the pilot cannot be relit until the thermocouple has cooled. If the knob does not pop up when released, stop and call your service technician or gas supplier; if the pilot will not stay lit after several tries, turn the gas control knob to OFF and call them. To turn the flames off, flip the burner switch to OFF; for the season or for servicing, also turn the gas shut-off valve to OFF.
Source: Enviro C-13833, p. 7; C-13833, p. 8
Yes. The Sienna can use an optional remote control or an optional cordless wall thermostat; the parts list has an on/off remote control kit, 50-559, and a programmable wall mounted remote control, 50-583. If you use one most of the time, leave the ON/OFF switch on the control panel in the remote/thermostat position. If the remote stops working, check its batteries, then check that the switch is not turned to OFF, the gas control valve is not at PILOT or OFF, and the pilot has not gone out.
Source: Enviro C-13833, p. 7; C-13833, p. 26; C-13833, p. 27
Enviro's troubleshooting table gives these checks. If the pilot will not stay lit: the thermocouple must be tight at the rear of the valve, the pilot flame must fully surround it, and it must read more than 5 mV at the valve, or it should be replaced; if the pilot dies while you hold the knob in, there may be air in the gas line, so bleed the line and check the gas pressure. If the burners will not stay lit: check the gas line pressure, the flame on the thermopile (at least 300 mV with the burner switched on) and the thermostat wiring, and on a B-vent Sienna check for spillage at the draft hood that may trip the spill switch. Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Source: Enviro C-13833, p. 26; C-13833, p. 2
It may be. The B-vent Sienna has a vent safety shutoff, a 300°F (149°C) manual reset spill switch (EC-003) on the rear of the appliance, that protects against improper venting of combustion products. If it trips more than once, have a qualified service technician inspect the venting for blockage or severe down draft. Draft can be checked with smoke at the ¼" tube at the front of the unit: suction into the tube means it is drafting properly, while air blowing out must be corrected before the unit is started. An air tight house or a vacuum in the room from another air-moving device can also starve it of combustion air; supply make up air to the unit.
Source: Enviro C-13833, p. 14; C-13833, p. 20; C-13833, p. 26; C-13833, p. 27
On first use, run the Sienna on high with the fan off for two to four hours (the approvals page says the first 4 hours) to cure the paint, logs and gasket, with a door or window open because it will smoke. Then turn it off, including the pilot, let it go completely cold and clean the glass with a gas fireplace glass cleaner. Clean the glass again about two weeks after the first burn, then no more than two or three times a season, with a mild glass cleaner and a soft cloth, never when hot; abrasive cleaners damage the glass. Condensation on a cold start is normal, and gas additives can make the glass hazy. The glass door comes off by removing two 5/16" bolts at the top outside corners of the glass frame, a step the manual places under qualified installers.
Source: Enviro C-13833, p. 8; C-13833, p. 4; C-13833, p. 9; C-13833, p. 10; C-13833, p. 26
Do not run the fireplace with the glass removed, cracked or broken; replacing the glass must be done by a licensed or qualified service person. The glass is a high temperature ceramic and needs a factory replacement from an Enviro dealer, with no substitute materials. The parts list has the door, glass and gasket as one part, 50-1112, and the dual bulb door gasket (10 feet), 50-634. A damaged glass door being transported must be wrapped in newsprint and tape or a strong plastic bag; wear gloves when handling it.
Source: Enviro C-13833, p. 9; C-13833, p. 27
Yes, with a conversion kit installed by a qualified service agency only. On Siennas with the convertible Nova valve, 50-1421, the kits are NG to LP 50-1441 and LP to NG 50-1440; each holds a burner orifice (NG #32 DMS or LP #49 DMS), a pilot injector (NG 0.62 mm or LP 0.35 mm), an instruction sheet and a conversion label, and the service agency flips the conversion screw in the valve. Early Siennas with separate natural gas and propane valves (EC-006 and EC-007) use kits 50-1119 (NG to LP) and 50-1118 (LP to NG), which replace the 50% turn down HI/LO regulator on the valve. The conversion label goes on or close to the rating label.
Source: Enviro C-13833, p. 11; C-13833, p. 12; C-13833, p. 27; C-10637, p. 10; C-10637, p. 25
The convection blower is thermostatically controlled: it comes on only when the fireplace is up to temperature, about 20 minutes after lighting, and turns off after the fireplace has cooled. Turn the fan control knob to change the speed, and counter-clockwise until it clicks to turn it off. Enviro advises not running the blower below 1/3 speed, which strains the windings and can cause premature fan failure. The fan plugs into a grounded three-prong outlet. Replacement parts include the convection blower, 115 V, EC-069, the fan controller EC-039 and the 120°F ceramic fan temperature sensor EC-001.
Source: Enviro C-13833, p. 8; C-13833, p. 18; C-13833, p. 27
At least once a year check that the burner ports are clear, that nothing blocks the pilot and that the pilot flame is blue with little or no yellow; have the venting examined by a qualified agency. The logs are fragile, and only the ember material supplied with the fireplace may be used on the burner. When lighting for the first time after replacing the logs and embers, watch for ignition at all the burner ports; if there is a long delay, turn it off, let it cool and rearrange the embers.
Source: Enviro C-13833, p. 9; C-13833, p. 22; C-13833, p. 23; C-13833, p. 24
The Sienna must always have one of its panels around it: the unit panel, the filler panel or the filler panel with trim. The surround hangs on four hooks, and draft relief openings must not be covered or blocked. Wipe the surround with a damp cloth periodically, never when hot; plated finishes stain from fingerprints.
Source: Enviro C-13833, p. 21; C-13833, p. 9
Sale price $61.62 CAD Regular price $67.99 CAD
| 1A | The Cottage trim kit, painted blackoption | 50-694 | Request it |
| 2A | Cape Cod doorsoption | 50-1097 | Request it |
| 3A | Unit panel and keystoneoption | 50-1108 | Request it |
| 4A | Cottageoption | 50-1109 | Request it |
| 5A | Filler paneloption | 50-1110 | Request it |
| 6A | Louvers (set of 2)option | 50-1111 | Request it |
| 7A | Panel trim set, 46" x 30" (117 cm x 76 cm), blackoption | 50-1113 | Request it |
| – |
| Conversion kit, NG to LP |
| 50-1119 |
| Request it |