Enviro Parts Only / One brand, every part
Search by Model / Find your exact unit
14-Day Returns / See our returns policy
Expert Advice / From people who care
Enviro Fireplace PartsEvery Enviro part, the right fit.
SupportWe're here to helpTrack OrderCheck status
Find My PartFind the right fit
  • Models
  • Find My Part
  • Manuals
  • Contact
Menu
  • Models
  • Find My Part
  • Manuals
  • Contact
Enviro Fireplace PartsEvery Enviro part, the right fit.
Find My Part Request a Part
Enviro Fireplace Parts

Every Enviro part, the right fit.

Get fitment tips, restock alerts, and Enviro parts news — straight to your inbox.

Shop

  • Shop by Model
  • Shop by Category
  • All Parts

Parts by Appliance

  • Wood Stove Parts
  • Gas Fireplace Parts
  • Pellet Stove Parts

Help & Support

  • Find My Part
  • Request a Part
  • Help Centre
  • Shipping & Delivery
  • Returns & Refunds
  • Warranty

Company

  • About Us
  • Contact Us
  • Blog

© 2026 Enviro Fireplace Parts. All rights reserved.

Enviro Fireplace Parts is operated by Friendly Fires Inc. · (705) 741-1900

PrivacyTermsAccessibility
  • Home
  • Models
  • Parts
  • Support
  • Cart
  1. Home
  2. Manuals
  3. Enviro Ri30

Manuals & parts · Direct vent gas fireplace insert

Enviro Ri30 Manuals

Quick answer

The current Enviro Ri30 manual is C-17181, the Ri30 Owner's Manual, a free PDF from enviro.com for the Ri30 IPI gas fireplace insert, listed from February 19, 2025. It is the only Ri30 manual Enviro lists. The rating label is on the left side of the unit.

The owner's manual for the Enviro Ri30 gas fireplace insert, the factory parts list with part numbers, key specs, and answers to common Ri30 questions, each taken from the official Enviro manual with the page number.

Last updated Nov 25, 2026 · From Enviro doc C-17181 · Answers drafted from the manuals; staff review pending

Shop Enviro Ri30 partsGet the manual

Which Enviro Ri30 do I have?

Ri30 (IPI)

Direct vent IPI gas fireplace insert with three burners (a base pan burner and left and right elevated burners), front and rear halogen ember lights and a convection fan, run by the Proflame 2 remote and integrated fireplace controller (IFC). Certified for natural gas or propane; a certified kit converts it between them. Traditional and birch log sets, five liners and several surround panels are sold as options.

Manuals: C-17181

Find your model and serial number: The rating label is located in the left side of the unit. (Enviro C-17181, p. 6)

Diagram of an Enviro Ri30 showing where the rating label with the model and serial number is: The rating label is located in the left side of the unit.
Where to find the Enviro Ri30 rating label. Our diagram, based on Enviro C-17181 p. 6.

Enviro Ri30 owner's and installation manuals

Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.

  • Ri30 Owner's Manual

    C-17181 · Feb 19, 2025 – Present · 46 pages · Current

    PDF

Enviro Ri30 parts from the manual, sold here

Enviro Door Tool — Enviro Fireplace Parts

Enviro Door & Glass Release Tool (50-2510)

Sale price $60.00 CAD Regular price $66.99 CAD

Enviro Gas Valve 50-2682 — Enviro Fireplace Parts

Enviro Gas Valve - SIT Proflame2 NG (50-2682)

Sale price $270.00 CAD Regular price $297.99 CAD

Enviro 50-3027 SIT Proflame 2 Battery Holder — Enviro Fireplace Parts

Enviro Remote Battery Holder (50-3027)

Sale price $41.82 CAD Regular price $46.99 CAD

Enviro Remote Control Replacement (50-3028 ) — Enviro Fireplace Parts

Can't open a link? Enviro lists every version on its manuals pages: Enviro Ri30 manuals.

Enviro Ri30 parts list, with part numbers

From the parts lists in the Enviro Ri30 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.

Ri30 (current manual) (Enviro C-17181, p. 42)

RefPartPart #Our store
1Fan only50-3901Request it
2Ri30 flue adaptor50-4665Request it
3Ri30 flue adaptor gasket50-4666Request it
4Ri door spring latches (set of 2)50-4667Request it
5Door release tool50-2510$60.00 CAD →
6Flue adaptor tool50-3505Request it
7SIT IPI valve50-2682$270.00 CAD →
8Battery holder, 4 x AA50-3027$41.82 CAD →
9Proflame 2 remote, wall mount50-3028$186.54 CAD →
–Proflame 2 IFC wire harness (0.584.045)50-3030Request it
10Proflame 2 IFC50-4103$330.77 CAD →
11PSE IPI pilot assembly50-4058$120.00 CAD →
–IPI LP pilot thimble50-4080$22.00 CAD →
–4 A glass fuse50-2076$37.65 CAD →
14Ri30 door complete50-4676Request it
–Ri30 door glass50-4677Request it
–Dual bulb door gasket (10 ft)50-634$68.00 CAD →
15Safety screen50-4089Request it
16Safety screen complete50-4699Request it
17Ri30 base burner50-4669Request it
18Ri30 left burner50-4670Request it
19Ri30 right burner50-4671Request it
–Orifice #51 long (NG main burners)50-4577Request it
–Orifice #54 long (NG base burner)50-4583Request it
–Orifice #58 long (LP main burners)50-4681Request it
–Orifice #63 long (LP base burner)50-4682Request it
20Ri30 steel baffle50-4678Request it
21Ri30 back tray assembly50-4668Request it
22Ri30 rear light cover50-4672Request it
23Ri30 rear light assembly50-4673Request it
24Ri30 front light cover50-4674Request it
25Ri30 front light assembly50-4675Request it
–Halogen socket with wires50-4632Request it
–35 W halogen bulb50-3291$15.00 CAD →
25Log grate50-2907Request it
26Ri30 base orifice mount (with gas line)50-4679Request it
27Ri30 main burner orifice mount (with gas line)50-4680Request it
28Ri30 steel lineroption50-4683Request it
28Ri30 brick lineroption50-4684$225.82 CAD →
28Ri30 ledgestone lineroption50-4685Request it
28Ri30 herringbone lineroption50-4686Request it
28Ri30 porcelain linersoption50-4694Request it
–Ri30 Galiano surroundoption50-4687Request it
–Ri30 Contemporary surroundoption50-4688$209.45 CAD →
–Ri30 Slim surroundoption50-4689Request it
–Ri30 Forgeworks faceoption50-4690Request it
–Ri30 trimmable filler paneloption50-4691Request it
–Ri30 traditional log setoption50-4692$672.00 CAD →
–Ri30 birch log setoption50-4693$808.36 CAD →
–NG to LP stepper motor only50-3753$187.20 CAD →
–LP to NG stepper motor only50-3870$115.00 CAD →
–Ri30 owner's manual50-4700Request it
–12 oz. can of metallic black touch-up paintPAINT-12-MBRequest it

Enviro Ri30 questions, answered from the manual

Where is the rating label on an Enviro Ri30?

On the left side of the unit. Have the installer record the model and serial number on the installation data sheet at the back of the manual. Enviro asks for the unit serial number on warranty claims.

Source: Enviro C-17181, p. 6; C-17181, p. 46; C-17181, p. 44

Which Ri30 manual do I need?

C-17181, the Ri30 IPI gas fireplace insert owner's manual, dated February 2025. Enviro lists it as current from February 19, 2025, and it is the only Ri30 manual on Enviro's Ri30 page, so it covers every Ri30.

Source: Enviro C-17181, p. 1; C-17181, p. 46

How do I turn on an Enviro Ri30?

The Ri30 has completely automatic ignition. Don't try to light the pilot by hand. Press ON/OFF on the Proflame 2 remote; the pilot lights, then the main burner, in about 10 seconds. The control tries to light the pilot several times if it needs to and stops if it can't. If the insert won't operate, follow the instructions to turn off the gas and call your service technician or gas supplier.

  1. Set the thermostat to its lowest setting and turn off all electric power to the insert. (C-17181, p. 8)
  2. Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, stop and follow the gas-smell instructions. (C-17181, p. 8)
  3. Turn the electric power back on. (C-17181, p. 8)
  4. Press ON/OFF on the remote, or set the remote thermostat to the temperature you want. ON shows on the display and the insert beeps to confirm. (C-17181, p. 8)
  5. The pilot lights first, then the main burner. This takes about 10 seconds. (C-17181, p. 11)

Source: Enviro C-17181, p. 8; C-17181, p. 11

My Ri30 remote stopped working. How do I re-sync it?

Check the simple causes first. The remote may be too far from the insert, or its batteries may be dead or low. A battery icon on the remote display means its three AAA batteries are low. If the controller doesn't beep when you press ON/OFF, its four AA backup batteries are low. After changing batteries, re-sync the remote to the controller.

  1. Turn off the main gas supply to the insert before you remove or reinsert the batteries in the battery holder. (C-17181, p. 9)
  2. Fit four AA batteries in the battery holder, matching the polarity marks on the holder. (C-17181, p. 11)
  3. Press and release the reset button. There is a red reset button at the front right corner of the controller (IFC) and a remote reset button on the lower right side of the cabinet. (C-17181, p. 10)
  4. The controller beeps three times to show it is ready to pair. (C-17181, p. 11)
  5. Fit three AAA batteries in the remote and press ON. Four beeps confirm the remote is synchronized. (C-17181, p. 11)

Source: Enviro C-17181, p. 40; C-17181, p. 13

What do the flashing lights on the Ri30 controller mean?

The LED on the Proflame 2 controller (IFC) blinks a code. One blink means a low battery condition (below 4V). Two blinks mean a parasitic pilot flame. Three blinks mean the system is locked out, for example after a failed ignition. The controller tries twice to light, each try lasting about 60 seconds, with about 35 seconds between them. Remove whatever caused the lockout, then reset the board. If the insert still won't light or stay lit, call a qualified service person: the manual says installation and repair should be done by a qualified service person.

  1. Turn the system off with the ON/OFF button on the remote. Wait about 2 seconds and press ON/OFF again. (C-17181, p. 41)
  2. Or, in manual flame mode, press the down arrow until OFF shows on the remote, wait about 2 seconds and press the up arrow. The ignition sequence starts. (C-17181, p. 41)
  3. Or, with the remote off, disconnect main power to the insert for a few seconds and reconnect it. Wait about 2 seconds and press the reset button on the IFC. (C-17181, p. 41)

Source: Enviro C-17181, p. 39; C-17181, p. 41; C-17181, p. 3

Why did my Ri30 pilot go out by itself?

In continuous pilot (CPI) mode the pilot turns itself off after 7 days without any main burner use. Relight the pilot to reset the counter. Enviro recommends CPI in winter when it is below 50°F (10°C) outside: it keeps the chimney warm so it drafts at ignition and cuts condensation on the glass. To switch modes, turn the insert off, press MODE on the remote until the CPI icon shows, then press the up arrow for continuous pilot or the down arrow to go back to intermittent pilot (IPI). If the pilot won't stay lit at other times, the troubleshooting table points to the flame sensor circuit, a pilot flame that is too small, gas pressure and the restrictor setting. Those checks are for a qualified service person, who the manual says should do any repair.

Source: Enviro C-17181, p. 14; C-17181, p. 40; C-17181, p. 3

Does the Ri30 work in a power outage?

Yes, the main burners run on a four AA battery backup when the power is out, but the fan and ember lights don't work on battery. The battery holder is behind the surround panel at the front bottom right of the fireplace; it slides out of a steel sleeve on the cabinet. Check the batteries once a year and replace them as needed. Turn off the main gas supply before you remove or reinsert them.

Source: Enviro C-17181, p. 13; C-17181, p. 9

Why is the Ri30 glass foggy, and how do I clean it?

Condensation on a cold start is normal and clears as the glass warms. Additives in the gas can also leave a haze, and the first paint cure leaves a film. Clean the glass once it has cooled after the first burn, again about two weeks later, then no more than two or three times a season, depending on use.

  1. Wait until the insert is completely cool. Never clean the glass when it is hot. (C-17181, p. 16)
  2. Lift the safety screen up and outward off its four hooks. The surround panel comes off the same way if you need it out of the way. (C-17181, p. 15)
  3. Release the two spring latches at the top of the door: put the hooked end of the door tool in the hole on each latch and pull it forward, then out to the side. Tilt the top of the door forward and lift it off. (C-17181, p. 15)
  4. Check that the gasket on the back of the glass is attached and intact. (C-17181, p. 16)
  5. Clean the glass with a mild glass cleaner and a soft cloth. Abrasive cleaners damage the glass and painted surfaces. (C-17181, p. 16)
  6. Refit the door by reversing the steps, then the safety screen. Never run the fireplace with the glass removed. (C-17181, p. 15)

Source: Enviro C-17181, p. 16; C-17181, p. 41; C-17181, p. 5

The Ri30 glass is cracked. What do I need?

Stop using the insert. Don't run it with the glass front cracked, broken or removed. The glass is a high-temperature ceramic and needs a factory replacement bought from an Enviro dealer; no substitute materials are allowed. Removing and replacing the glass in the door must be done by a licensed or qualified service person. The parts list gives 50-4677 for the Ri30 door glass and 50-4676 for the complete door.

Source: Enviro C-17181, p. 16; C-17181, p. 42

How do I replace an Ri30 ember light bulb?

The Ri30 has three halogen bulbs under the front ember tray and two under the rear ember tray. The bulb is a GY6.35 bi-pin base, 120V, 35W halogen, Enviro part 50-3291. The three burners can stay in place.

  1. Disconnect electrical power to the insert, and let it cool completely before opening it. (C-17181, p. 19)
  2. Remove the log set, side air diverters and log grate as for burner removal. (C-17181, p. 19)
  3. Front lights: clear the glass and coal media off the front ember tray, remove its two T20 screws and lift the tray out, remove the two T20 screws holding the light tray, then undo the T20 at the back of the light tray to take off the bulb cover. (C-17181, p. 19)
  4. Rear lights: clear the glass off the rear ember tray, remove its T20 retaining screw and lift the tray out. (C-17181, p. 19)
  5. Wearing cotton gloves, pull the old bulb straight out by its base and fit the new one, holding it by its foam sleeve. Bare fingers on the bulb greatly shorten its life. (C-17181, p. 19)

Source: Enviro C-17181, p. 19

Can I convert an Ri30 from natural gas to propane?

Only with the certified conversion kit, installed by a qualified service agency. The Ri30 kit contains LP burner orifices (2 x #58 and 1 x #63), an LP pilot orifice, four LP log spacers, an LP stepper motor with hardware and label, and conversion labels. The installer changes the pilot orifice, the burner orifices and the valve's stepper motor, adjusts the burner air shutters, fits the log spacers, leak-tests the gas connections, checks the inlet and manifold pressures, and puts the conversion labels on or close to the rating label.

Source: Enviro C-17181, p. 2; C-17181, p. 21; C-17181, p. 22

Key specs

Gas input, natural gas
21,000 to 32,000 BTU/h (C-17181, p. 32)
Gas input, propane
25,000 to 32,000 BTU/h (C-17181, p. 32)
Manifold pressure
1.6 to 3.6" W.C. natural gas, 6.4 to 10.0" W.C. propane (C-17181, p. 32)
Main burner orifices
2 x #51 and 1 x #54 DMS natural gas; 2 x #58 and 1 x #63 DMS propane (C-17181, p. 32)
Venting
3" intake and 3" exhaust aluminum or stainless steel flexible vent to a vertical termination cap, 10 to 40 ft (3.05 to 12.2 m) (C-17181, p. 24)
Exhaust restrictor
Setting 1 for 10 to 20 ft of vent, 2 for 20 to 30 ft, 3 for 30 to 40 ft; set to 1 at the factory (C-17181, p. 26)
Minimum fireplace opening
30" wide at front, 20" wide at back, 20" high, 15" deep (C-17181, p. 23)
Install depth
15" (382mm) with the Contemporary surround; 16" (406mm) with the Galiano, Slim or Forgeworks surround (C-17181, p. 6)
Clearances
6" (152 mm) from the door edge to side walls; a 4" (102 mm) mantel at least 36" from the bottom of the unit; ceiling 56" (142 cm) from the bottom of the unit; no floor protection required in front (C-17181, p. 23)
Certified altitude
0 to 4500 ft (1372 m) (C-17181, p. 5)
Remote and controller
Proflame 2 transmitter on three 1.5 V AAA batteries, 315 MHz; IFC on 120 V / 60 Hz with four 1.5 V AA batteries as backup (C-17181, p. 9)

Need a part for your Enviro Ri30?

16 of 53 parts-list items are sold here.

Shop Enviro Ri30 partsNot sure which part? Find my part

Gas work, venting, electrical and glass replacement must be done by a qualified installer or service agency. These answers summarize Enviro's manuals; the manual for your exact model and serial number is the authority.

Enviro Remote Control Replacement (50-3028 )

Sale price $186.54 CAD Regular price $205.99 CAD

Enviro 50-3202 Remote Receiver — Enviro Fireplace Parts

Enviro Fireplaces SIT Proflame 2 Remote Receiver (50-4103/ 50-3791 /50-3312/50-3202)

Sale price $330.77 CAD Regular price $363.99 CAD

Envio Fireplaces 50-3026 IPI Pilot Assembly — Enviro Fireplace Parts

Enviro Fireplaces Natural Gas Pilot Assembly Replacement - IPI Models (50-4058)

Sale price $120.00 CAD Regular price $132.99 CAD

Enviro Propane Pilot Assembly - Many IPI Fireplace Models (50-3997) — Enviro Fireplace Parts

Enviro Propane Pilot Orifice - Many IPI Fireplace Models (50-4080)

Sale price $22.00 CAD Regular price $24.99 CAD

Enviro Fuse 50-2076 — Enviro Fireplace Parts

Enviro Fuses - 4 Amps (50-2076)

Sale price $37.65 CAD Regular price $41.99 CAD

See all Enviro Ri30 parts →
, and 16 parts are tagged to fit the Enviro Ri30