Manuals & parts · Direct vent gas fireplace (discontinued)
Quick answer
The Enviro Retreat is a discontinued direct vent gas fireplace built by Sherwood Industries, and Enviro lists all of its manuals as archived. The last owner's manual is C-11081, listed from Mar 23, 2006, a free PDF from enviro.com; the two 2005 editions list a different gas valve and conversion kits. Retreat parts are still sold here, and the rating label is on a metal plate chained to the fireplace under the control panel.
Every Retreat owner's manual Enviro still publishes, the factory parts lists with part numbers (components, ceramic firebox liners, vent kits and the Chalet and Cape Cod faces), key specs, and answers to common Retreat questions, each taken from the official manual with the page number. Enviro no longer makes the Retreat, but we still sell its parts.
Last updated · From Enviro docs C-11081 and C-10968 · Answers drafted from the manuals; staff review pending
Retreat (2006, convertible valve)
Direct vent gas fireplace with a pilot lit by hand with a piezo ignitor, a HI/LO flame knob and an ON/OFF/Remote burner rocker switch, which is also used with an optional remote, wall thermostat or wall switch. The last manual, C-11081, lists the convertible S.I.T. Nova valve 50-1421, converted between natural gas and propane with kit 50-1438 or 50-1439 by flipping the valve's conversion screw.
Manuals: C-11081
Retreat (2005, fuel-specific valve)
The two 2005 manuals list separate natural gas and propane S.I.T. Nova valves (EC-006 and EC-007, 50% turn down) and conversion kits 50-1336 (NG to LP) and 50-1337 (LP to NG) that replace the HI/LO regulator on the valve. The rest of the component parts list is the same as in C-11081. C-10807 is the file Enviro publishes as a low res copy.
Manuals: C-10968, C-10807
Find your model and serial number: The rating label is under the control panel, attached to a rectangular metal sheet that is chained to the fireplace. (Enviro C-11081, p. 5)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro Retreat is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro Retreat parts.
Can't open a link? Enviro lists every version on its manuals pages: Enviro Retreat manuals, Enviro legacy manuals.
From the parts lists in the Enviro Retreat manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Ceramic fan temperature sensor, 120 °F | EC-001 | $77.79 CAD → |
| 2 | S.I.T. Nova valve, NG, convertible | 50-1421 | Request it |
| 3 | Thermocouple | EC-009 | Request it |
| 3 | Spark electrode with ignitor cable | EC-011 | $72.73 CAD → |
| 3 | Thermopile | EC-012 | $88.33 CAD → |
| 3 | Pilot orifice, NG, threaded | EC-019 | $61.62 CAD → |
| 3 | Pilot orifice, LP, threaded | EC-020 | $72.00 CAD → |
| 3 | Pilot gasket | EC-021 | $24.44 CAD → |
| 3 | SIT pilot ⅛" tube with end ferrules (1 piece) | 30-043 | $59.75 CAD → |
| 3 | Three flame pilot hood | 50-925 | $9.00 CAD → |
| 4 | S.I.T. piezo ignitor | EC-023 | $44.25 CAD → |
| 5 | Burner switch | EC-026 | $30.00 CAD → |
| 6 | Fan controller, 115 V | EC-039 | Request it |
| 7 | Convection blower, 115 V | EG22-001 | Request it |
| 7 | Convection blower kit, 115 Voption | 50-1211 | Request it |
| 8 | Enviro logo gel decal | 50-322 | Request it |
| – | Blank orifice #73 | 50-343 | $35.47 CAD → |
| 9 | On/off remote control kitoption | 50-559 | Request it |
| – | Programmable wall mounted remote controloption | 50-583 | Request it |
| 10 | Dual bulb door gasket, 10 ft (3.05 m) | 50-634 | $68.00 CAD → |
| 10 | Door, glass and gasket | 50-1338 | Request it |
| – | Wall switch kitoption | 50-920 | Request it |
| 11 | Retreat owner's manual | 50-1269 | Request it |
| 12 | Manual shut-off valve | 50-1284 | Request it |
| 13 | Door latch spring, bracket and screws (set of 2) | 50-1285 | Request it |
| 14 | Pilot shield | 50-1287 | Request it |
| 15 | Valve assembly with pilot and mount | 50-1349 | Request it |
| 16 | Bell wire, 20 ft (6.1 m) | 50-1291 | Request it |
| 17 | Log and coal set | 50-1295 | Request it |
| 18 | Conversion kit, NG to LP, convertible | 50-1438 | Request it |
| 18 | Conversion kit, LP to NG, convertible | 50-1439 | Request it |
| 19 | Pan burner | 50-1339 | Request it |
| 20 | Control panel | 50-1340 | Request it |
| – | S.I.T. valve conversion screw with o-ring | 50-1450 | Request it |
| – | S.I.T. valve conversion screw cap | 50-1451 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 21 | Firebox liner, Bankers Brown Brickoption | 50-1227 | Request it |
| 21 | Firebox liner, Arizona Stuccooption | 50-1228 | Request it |
| 21 | Firebox liner, Red Brickoption | 50-1229 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 2 | S.I.T. Nova valve, NG (50% turn down) | EC-006 | Request it |
| 2 | S.I.T. Nova valve, LP (50% turn down) | EC-007 | Request it |
| 18 | Conversion kit, NG to LP | 50-1336 | Request it |
On the rating label. It is under the control panel, attached to a rectangular metal sheet that is chained to the fireplace; the control panel drawing in the manual marks it below the panel. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-11081, p. 5; C-11081, p. 8; C-11081, p. 42
The Retreat is discontinued and Enviro lists all three Retreat owner's manuals as archived. Use C-11081, listed from Mar 23, 2006, the last edition: it covers lighting, maintenance, fuel conversion, installation, venting, troubleshooting and the parts lists. The two 2005 editions, C-10968 and C-10807 (published by Enviro as a low res copy), differ mainly in the gas valve: their parts list has separate natural gas and propane S.I.T. Nova valves (EC-006 and EC-007) and conversion kits 50-1336 / 50-1337 that change the HI/LO regulator, where C-11081 lists the convertible valve 50-1421 and kits 50-1438 / 50-1439.
Source: Enviro C-11081, p. 3; C-11081, p. 37; C-10968, p. 36; C-10968, p. 11
The Retreat's pilot is lit by hand with the gas control knob and the piezo ignitor; the pilot sits to the right, behind the side log. If you smell gas at any point, stop, do not light anything and call your gas supplier from a neighbour's phone. The valve has a lockout that will not let the pilot be relit until the thermocouple has cooled. If the knob does not pop up when released, or the pilot will not stay lit after several tries, turn the knob to OFF and call your service technician or gas supplier. To turn the flames off, flip the burner switch to OFF; for the season or for service, also turn the gas shut-off valve to OFF.
Source: Enviro C-11081, p. 6; C-11081, p. 8
The Retreat can run on an optional remote control or cordless wall thermostat, a wired thermostat or a wall switch. For a remote or thermostat, the ON/OFF switch on the control panel must be left in the remote/thermostat position. Enviro's troubleshooting chart lists dead batteries in the remote, that switch turned to OFF, the gas control valve left at PILOT or OFF, and a pilot that has gone out. If the main burner does not light when the thermostat calls for heat, check the gas control knob is at ON and set the thermostat several degrees above room temperature. The parts list has an on/off remote control kit 50-559, a programmable wall mounted remote control 50-583 and a wall switch kit 50-920.
Source: Enviro C-11081, p. 8; C-11081, p. 29; C-11081, p. 36; C-11081, p. 37
Enviro's troubleshooting chart points first to the thermocouple circuit: the thermocouple connection at the back of the valve may be loose, the pilot flame may not fully surround the thermocouple (a small flame can mean low gas pressure, a pilot rate screw that needs adjusting or a damaged pilot head), or the thermocouple voltage at the valve may be low; it must be greater than 5 mV. If the pilot dies while you are still holding the knob in, there may be air in the gas line. If the piezo ignitor gives no spark, its connections or the spark electrode may be at fault. These checks are for a qualified service technician. The thermocouple is EC-009 and the piezo ignitor EC-023 in the parts list.
Source: Enviro C-11081, p. 36; C-11081, p. 6; C-11081, p. 37
The blower is the optional fan kit 50-1211, and a 14/2 (with ground) power cable has to be hard-wired to the fireplace for it. It is thermostatically controlled and only comes on once the fireplace is up to temperature, about 20 minutes after lighting, and it turns off a few minutes after the fireplace is shut off. Turn the fan control knob to set the speed; turning it counter-clockwise until it clicks turns the blower off. Enviro advises not running it below 1/3 speed, which strains the blower windings and can cause early fan failure.
Source: Enviro C-11081, p. 29; C-11081, p. 7; C-11081, p. 31
Only when the fireplace is off and completely cold. Condensation on the glass during a cold start is normal and clears as the fireplace warms up, but it lets dust and lint cling to the glass, and additives in the gas can make it hazy. Clean the glass about two weeks after installation, then usually no more than two or three times a season, with a mild glass cleaner and a soft cloth; abrasive cleaners damage the glass. A white film from gas impurities comes off with ceramic polish. Never run the fireplace with the glass removed.
Source: Enviro C-11081, p. 9; C-11081, p. 10; C-11081, p. 36
Stop using the fireplace: it must not run with the glass removed, cracked or broken. The glass is a high temperature ceramic, so a factory replacement is required, bought from an Enviro dealer; substitute materials void the warranty. Removing and replacing the glass must be done by a licensed or qualified service person. Wear gloves when handling a damaged door, and wrap it in newsprint and tape or a strong plastic bag to transport it. In the parts list the door, glass and gasket is 50-1338 and the dual bulb door gasket (10 feet) is 50-634.
Source: Enviro C-11081, p. 9; C-11081, p. 37
Yes, with the conversion kit, installed by a qualified service agency only. The parts list in the last manual has kit 50-1438 (NG to LP) and 50-1439 (LP to NG). The kit holds a main burner orifice (#40 DMS natural gas, #55 DMS propane), a pilot injector (0.62 mm natural gas, 0.35 mm propane), an instruction sheet and a conversion label. The burner orifice and pilot injector are changed, and the S.I.T. valve's conversion screw is flipped so its red o-ring is visible for propane and hidden for natural gas. The conversion label goes on or close to the rating label. The two earlier manuals list different kits, 50-1336 (NG to LP) and 50-1337 (LP to NG), which change the HI/LO regulator on the valve.
Source: Enviro C-11081, p. 11; C-11081, p. 12; C-11081, p. 37; C-10968, p. 11; C-10968, p. 36
Enviro says the fireplace should be inspected before first use and at least once a year by a qualified service person, more often if lint from carpets or bedding builds up, and the venting system inspected for blockage and deterioration. At least once a year, check that the burner ports are clear and clean and the pilot is not blocked; the pilot flame should be blue with little or no yellow on the tips. Also check the logs and charcoal pieces for deterioration or large amounts of soot; a small amount on the underside of the logs is normal. The ceramic firebox liner must be in place before the fireplace is lit.
Source: Enviro C-11081, p. 2; C-11081, p. 9; C-11081, p. 34
Sale price $61.62 CAD Regular price $67.99 CAD
| – | Fireplace horizontal vent kit, 5 ft (1.52 m)option | 50-1235 | Request it |
| – | Fireplace horizontal vent kit, 10 ft (3.05 m)option | 50-1293 | Request it |
| 22 | Chalet face, inset and bottom door, black enameledoption | 50-1226 | Request it |
| 22 | Chalet face, inset and bottom door, bronze enameledoption | 50-1315 | Request it |
| 23 | Chalet inset, brushed nickeloption | 50-1309 | Request it |
| 23 | Chalet inset, brushed goldoption | 50-1310 | Request it |
| 23 | Chalet inset, bronze enameledoption | 50-1324 | Request it |
| 23 | Chalet inset, black enameledoption | 50-1325 | Request it |
| 24 | Cape Cod face and bottom door, black enameledoption | 50-1231 | Request it |
| 24 | Cape Cod face and bottom door, bronze enameledoption | 50-1316 | Request it |
| 25 | Cape Cod inset, black enameledoption | 50-1326 | Request it |
| 25 | Cape Cod inset, bronze enameledoption | 50-1327 | Request it |
| 25 | Cape Cod inset, brushed nickeloption | 50-1334 | Request it |
| 25 | Cape Cod inset, brushed goldoption | 50-1335 | Request it |
| 18 | Conversion kit, LP to NG | 50-1337 | Request it |