Where is the serial number on an Enviro Q2?
On the rating label. The rating label and the lighting instructions are plates attached to the fireplace with a length of chain, and they must never be removed. On the Q2L and Q2LI you reach them by removing the front face. On the Q2G and Q2GI you flip down the control cover; the Q2G manual shows the plates in the control area below the firebox. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-15720, p. 6; C-15829, p. 6; C-15720, p. 46
Which Q2 manual do I need?
Read the letters after Q2. L means a log set and G means glass media. A trailing I means intermittent pilot ignition (IPI) with the Proflame 2 remote, and an extra D (Q2LID, Q2GID) means a Dexen control with its own Dexen user manual; no I means a millivolt Nova valve with a pilot you light by hand. The current manuals are C-15720 for the Q2L, C-15721 for the Q2LI and Q2LID, C-15829 for the Q2G and C-15830 for the Q2GI and Q2GID. Enviro also lists archived 2019 editions, the 2015 to 2019 -S editions and the 2014 first edition, C-14372, titled simply Q2; pick the one whose dates cover your fireplace.
Source: Enviro C-15720, p. 1; C-15721, p. 1; C-15721, p. 9; C-15829, p. 1; C-15830, p. 1; C-14372, p. 1
How do I light the pilot on a Q2L or Q2G?
The Q2L and Q2G have a pilot you light by hand with the piezo ignitor, following the lighting label. The valve has a lockout: if the pilot goes out it will not relight until the thermocouple has cooled. If the knob does not pop up when released, stop and call your service technician or gas supplier; if the pilot will not stay lit after several tries, turn the knob to OFF and call them. The pilot is on-demand and shuts off after 7 consecutive days without the main burner running.
- Set the thermostat to the lowest setting, turn off all electric power to the fireplace and open the front control panel. (C-15720, p. 7)
- Turn the gas control knob clockwise to OFF. Open the door and wait five minutes to clear out any gas, then close it and smell for gas, including near the floor. If you smell gas, stop. (C-15720, p. 7)
- Turn the gas control knob counter-clockwise to PILOT, push it in fully and, while holding it in, press the piezo ignitor several times until the pilot lights. (C-15720, p. 8)
- Keep the knob pressed in for about 60 seconds after the pilot lights, or until you hear a beep, then release it. If the pilot goes out, repeat the lighting steps. (C-15720, p. 7)
- Turn the knob counter-clockwise to ON, flip the burner switch to ON and set the HI/LOW knob. Close the control panel, turn the power back on and set the thermostat. (C-15720, p. 7)
Source: Enviro C-15720, p. 7; C-15720, p. 8
How do I set up the Q2LI or Q2GI remote?
The Q2LI and Q2GI run on the Proflame 2 remote and its integrated fireplace controller (IFC). The remote takes three AAA batteries and the IFC has a four AA battery backup. The remote turns the fireplace on and off, sets six flame levels and six fan speeds, and works as a thermostat or a smart thermostat that turns the flame down as the room nears the set point. Synchronize it the first time and after the batteries have been replaced. The Q2LID and Q2GID use a Dexen control instead; follow the separate Dexen user manual.
- Put the four AA batteries in the IFC battery holder, following the polarity marked on the holder. (C-15721, p. 11)
- Press the reset button marked SW1 on the IFC. It beeps three times when it is ready to synchronize. (C-15721, p. 11)
- Put three AAA batteries in the base of the remote and press its ON button. The IFC beeps four times to confirm it has taken that remote's code. (C-15721, p. 11)
- Press the ON/OFF key to light the fireplace: the pilot lights first, then the main burner, in about 10 seconds. (C-15721, p. 11)
Source: Enviro C-15721, p. 9; C-15721, p. 10; C-15721, p. 12; C-15721, p. 13
My Q2LI or Q2GI will not light or the controller light is blinking. What should I check?
The Proflame 2 IFC tries twice to light, each try lasting about 60 seconds with about 35 seconds between them. If it cannot light it locks out and its LED blinks 3 times until the system is reset; one blink means low battery and two blinks a parasitic pilot flame. Air in the gas line can take a while to purge before the pilot lights. If the remote gets no reaction, use it closer to the fireplace, replace the remote and IFC batteries, or re-synchronize the remote as for first-time setup. These flash codes do not apply to the Dexen D models; see the Dexen user manual. If the fireplace still will not operate, turn off the gas to it and call your service technician or gas supplier.
Source: Enviro C-15721, p. 42; C-15721, p. 43; C-15721, p. 7
Does a Q2 work in a power outage?
The millivolt Q2L and Q2G do: the pilot flame makes enough electricity to run the main burner, so they operate without household power, though the optional fan needs power. The Q2LI and Q2GI controllers run mainly on 120 VAC but can run on the four AA battery backup for shorter periods. When the controller batteries are low it no longer beeps when you press ON/OFF on the remote.
Source: Enviro C-15720, p. 34; C-15721, p. 10; C-15721, p. 13
Why does the glass on my Q2 fog up, and how do I clean it?
Condensation on a cold start is normal and clears once the fireplace warms up, but it lets dust and lint cling to the glass, and additives in the gas can make it hazy. Paint curing also leaves a film, so clean the glass about two weeks after installation, then no more than two or three times a season, with a mild glass cleaner and a soft cloth, only when it is cool; abrasive cleaners damage the glass. On the IPI models Enviro recommends the continuous pilot (CPI) mode in winter below 50°F (10°C), which keeps the firebox warm and cuts condensation on the door glass.
Source: Enviro C-15720, p. 10; C-15720, p. 40; C-15721, p. 11
How do I take the glass door off a Q2?
Only when the fireplace is completely cold, and never run it with the door off. The safety screen lifts off first, then the door unhooks from two spring latches at the top. The glass is high temperature ceramic: if it is cracked or damaged, stop using the fireplace; the glass must be replaced with the factory part by a licensed or qualified service person. The Q2L parts list gives door glass with gasket 50-3021.
- Make sure the fireplace is completely cold. (C-15720, p. 11)
- Remove the safety screen by grabbing the top and bottom of its frame and lifting it up and out. (C-15720, p. 11)
- With your two index fingers, pull the spring latches up over the two door tabs. (C-15720, p. 11)
- Pivot the door forward and pull it out of the bottom door retainers; it has to be angled to come out. (C-15720, p. 11)
- To refit the door, reverse these steps. (C-15720, p. 11)
Source: Enviro C-15720, p. 11; C-15720, p. 10; C-15720, p. 41
Can I convert a Q2 from natural gas to propane?
Yes, with the conversion kit for your model, installed by a qualified service agency only. For the millivolt Q2L and Q2G the kits are 50-3035 (natural gas to propane) and 50-3034 (propane to natural gas): they swap the burner orifice (#40 DMS natural gas, #55 DMS propane) and the pilot injector, and the Nova valve screw is flipped. The Q2LI and Q2GI kit to propane, 50-3061, swaps the burner orifice and pilot orifice and replaces the valve's stepper regulator. The conversion label goes on or close to the rating label.
Source: Enviro C-15720, p. 41; C-15720, p. 13; C-15720, p. 14; C-15721, p. 17; C-15721, p. 18; C-15720, p. 15
Can a Q2 be vented out the back?
The Q2L and Q2LI can be converted from top vent to rear vent for smaller openings; the Q2G and Q2GI can only be run as a top vent. A rear vent goes straight out through the wall behind the fireplace with no vertical rise (if the run needs any rise, use top venting), and Enviro strongly recommends a 14 inch snorkel termination. Top vent runs use 4 x 6 5/8 inch co-axial pipe from 6 inches to 40 feet, with no more than 20 feet of horizontal pipe, and the supplied exhaust restrictors are set to suit the run. Venting is a job for a qualified installer.
Source: Enviro C-15720, p. 16; C-15720, p. 17; C-15721, p. 21; C-15720, p. 25; C-15720, p. 21; C-15720, p. 26; C-15720, p. 28