Where is the serial number on an Enviro EG28?
On the rating label, which is inside the right cabinet side panel on both the DV and BV versions. The label also shows the type of gas the stove is set up for. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-13840, p. 5; C-13841, p. 5; C-13840, p. 1; C-13840, p. 37
Is my EG28 the DV or the BV, and which manual do I need?
The EG28 DV (direct vent) takes all of its combustion air from outside through a specially designed vent pipe system. The EG28 BV takes its combustion air from the room, is vented with B or L vent or a chimney liner, has a vent opening at the rear, and the label on its right side panel door says "Vented Room Heater". The EG28 is discontinued and Enviro lists every manual as archived. Use C-13840 for a DV and C-13841 for a BV, the last editions; older stoves may match earlier editions by date (2006, 2005 and 2003, each in a DV and a BV version).
Source: Enviro C-13840, p. 4; C-13841, p. 4; C-13841, p. 13
How do I light the pilot on an EG28?
The EG28 has a millivolt valve with a pilot you light by hand, following the lighting label; the steps are the same on the DV and BV. Use only your hand on the gas control knob: if it will not push in or turn by hand, don't force it and call a qualified service technician. The valve has a lockout, so the pilot cannot be relit until the thermocouple has cooled; if the knob does not pop up when released, stop and call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the knob to OFF and call them.
- Turn off all electrical power to the stove and turn the gas control knob clockwise to OFF. (C-13840, p. 6)
- Open the door and wait five minutes to clear out any gas, then close it. If you smell gas, stop and follow the safety instructions on the label. (C-13840, p. 6)
- Find the pilot, to the right between the front and rear burner. Turn the gas control knob counter-clockwise to PILOT, push it in fully and hold it. (C-13840, p. 6)
- While holding the knob in, light the pilot with the spark ignitor. (C-13840, p. 31)
- Keep the knob pressed in for about 30 seconds after the pilot lights, then release it. If the pilot goes out, start again from the five minute wait. (C-13840, p. 6)
- Turn the knob counter-clockwise to ON, flip the burner switch to ON, set the HI/LOW knob, then turn the electrical power back on. (C-13840, p. 6)
Source: Enviro C-13840, p. 6; C-13841, p. 6
How do I open the EG28 door and clean the glass?
Clean the glass only after it has cooled. Condensation on a cold start is normal, and the first paint cure can leave a light film, so Enviro recommends cleaning the glass after about the first four hours of use; after that it should need cleaning no more than two or three times a season. Use a mild glass cleaner and a soft cloth, or a glass cleaner from your Enviro dealer: abrasive cleaners damage the glass. The bay window door is held by a fastener behind the right-hand side flap.
- Turn the stove off and wait until it has cooled down. (C-13840, p. 8)
- Open the right-hand hinged side flap to reach the door fastener and loosen it with a ½" wrench. (C-13840, p. 8)
- Open the left-hand side flap too: the shape of the bay window door means both flaps must be open before the door will open. (C-13840, p. 8)
- Open the door. To take it off, lift the door pins out of the hinges. (C-13840, p. 8)
- Clean the glass with a mild glass cleaner and a soft cloth. (C-13840, p. 8)
- Close the door and make sure it is properly fastened before you relight the stove. (C-13840, p. 8)
Source: Enviro C-13840, p. 8
The EG28 glass is broken. What do I need?
Stop using the stove: Enviro says not to operate it with the glass removed, cracked or broken. The ceramic glass is part of the door assembly, so a factory door with glass must be used, bought from an Enviro dealer (part EG28-103); substitute materials void the warranty. Replacing the glass must be done by a licensed or qualified service person.
Source: Enviro C-13840, p. 8; C-13840, p. 2; C-13840, p. 32
Why won't the pilot on my EG28 stay lit?
Enviro's troubleshooting table lists two causes. A thermocouple problem: check the thermocouple is fully tightened into the back of the valve, that the pilot flame fully surrounds it (if the flame is small, check gas pressure, the pilot rate screw and the pilot head), and that it gives more than 5 mV at the valve; if not, replace the thermocouple. Or air in the gas line, if the pilot dies while you hold the knob in: the line needs bleeding and the gas pressure checked, so contact your dealer. If the pilot or burners go out on their own, open the glass door and wait 5 minutes before you relight.
Source: Enviro C-13840, p. 31; C-13840, p. 2
My EG28 flames are sooty or too blue. How are they adjusted?
The air to the burner is set with the venturi shutter, reached by taking off the ash shelf and the cover plate below it. The ideal flame is blue at the base and light orange above, of medium height. Short, mostly blue flames get too much air, so the venturi is closed slightly; very orange flames with tall, dark, stringy tips need more air, so it is opened. The manual's venturi table gives a minimum opening of 1/16" for natural gas and ¼" for propane. Blue flames at start-up are normal; for sooting, also check the log positions. Enviro warns that incorrect venturi adjustment is a safety hazard: if the right flame can't be reached, turn off the gas and contact your dealer.
Source: Enviro C-13840, p. 7; C-13840, p. 31
My EG28 BV keeps shutting off. Is it the spill switch?
It may be. The BV has a vent safety shutoff, a spill switch at the rear near the draft hood relief opening, which shuts the stove off if combustion products spill out instead of going up the vent. If it trips more than once, have the chimney inspected by a qualified service technician for blockage or severe down draught. The BV draws its combustion air from the room, so an airtight house or a fan creating a vacuum in the room can also starve it: supply make-up air. Never block the louvers or tamper with the shutoff system.
Source: Enviro C-13841, p. 12; C-13841, p. 13; C-13841, p. 20
Can I convert an EG28 from natural gas to propane?
Yes, with a conversion kit installed by a qualified service agency only. The kit changes the main orifice (#43 DMS natural gas, #53 DMS propane) and the pilot injector (0.62 mm natural gas, 0.35 mm propane), and the S.I.T. valve's conversion screw is flipped so its red O-ring shows for propane. The installer leak-tests, relights the burner on HI and LO, and fits the conversion label on or near the rating label. The parts lists give 50-1431 (natural gas to propane) and 50-1430 (propane to natural gas) for the convertible valve.
Source: Enviro C-13840, p. 10; C-13840, p. 11; C-13840, p. 33
Does the EG28 work in a power outage?
Yes. The EG28 has a millivolt gas control that runs on electricity made by the pilot flame, so it operates without household power. The blower does need power: it plugs into a properly grounded three-prong outlet.
Source: Enviro C-13840, p. 27
How do I replace the blower on an EG28?
The convection blower (50-512 in the parts lists) is reached from inside the firebox once the door, logs and burner are out. A 120 °F (49 °C) temperature sensor switches the blower on and off as the stove heats and cools, so a faint click from it is normal.
- Turn the stove off, let it cool completely and remove the door. (C-13840, p. 9)
- Take out the log set carefully. (C-13840, p. 9)
- Remove the two T-20 screws that fasten the lower half of the burner bracket to the burner tray (inside the large hole in the burner), slide the burner to the left and lift it up and out. (C-13840, p. 9)
- Remove the four 5/16" bolts holding the blower mounting plate to the back firewall, using a light lubricating oil on them first. (C-13840, p. 9)
- Pull the blower into the firebox, disconnect its leads from the harness and remove it. (C-13840, p. 9)
- Check the mounting plate gasket, replace it if damaged, and reassemble in reverse order, lining up the venturi box under the burner. (C-13840, p. 9)
Source: Enviro C-13840, p. 9; C-13840, p. 33; C-13840, p. 32; C-13840, p. 7
Why does my new EG28 smoke and smell the first time?
That is the paint, logs and gasket material curing. Enviro says to run a new stove on high, without the fan, for the first 4 hours, with a window or door open because the smoke can irritate some people. Then turn it off, including the pilot, let it go cold, and clean the glass with a gas fireplace glass cleaner.
Source: Enviro C-13840, p. 4