Manuals & parts · Direct vent gas fireplace (discontinued)
Quick answer
The Enviro DV50DX is a discontinued direct vent gas fireplace, and Enviro lists all of its manuals as archived. The last owner's manual is C-11291, dated April 4, 2007, a free PDF from enviro.com; fireplaces from 2003 to 2006 match the earlier editions by date. DV50 parts are still sold here, and the rating label is under the control panel, on a metal plate chained to the fireplace.
Every DV50DX owner's manual Enviro still publishes, the factory parts lists with part numbers (valve, pilot parts, blower, door and glass, burner, logs and the optional faces), key specs, and answers to common DV50DX questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the DV50DX, but we still sell its parts.
Last updated · From Enviro docs C-11291 and C-10986 · Answers drafted from the manuals; staff review pending
DV50DX (2006 to 2007 manuals)
Direct vent gas fireplace with a hand-lit standing pilot and piezo ignitor, a burner switch and HI/LO knob, a convection blower with a variable fan control, and an air diverter that sends the blower air to the room, to a duct or both. It has the S.I.T. Nova convertible valve: a fuel conversion changes the burner orifice and pilot injector and flips the valve's conversion screw.
Manuals: C-11291, C-11079
DV50DX (2003 to 2005 manuals)
Earlier fireplaces with a separate S.I.T. Nova valve for natural gas and for propane (50% turn down), converted by changing the HI/LO regulator on the valve along with the pilot injector and burner orifice. Use the edition whose date matches your installation.
Manuals: C-10986, C-10767, C-10121, C-10044
Find your model and serial number: The rating label is under the control panel, attached to a rectangular metal sheet that is chained to the fireplace. (Enviro C-11291, p. 5)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro DV50DX is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro DV50DX parts.
DV50DX Owner's Manual
C-11291 · Apr 4, 2007 – Present
DV50DX Owner's Manual
C-11079 · Mar 20, 2006 – Apr 04, 2007
DV50DX Owner's Manual
C-10986 · Nov 10, 2005 – Mar 20, 2006
DV50DX Owner's Manual
C-10767 · Nov 26, 2004 – Nov 10, 2005
DV50DX Owner's Manual
C-10121 · Nov 19, 2003 – Nov 26, 2004
DV50DX Owner's Manual
C-10044 · Sep 3, 2003 – Nov 19, 2003
Can't open a link? Enviro lists every version on its manuals pages: Enviro DV50DX manuals, Enviro legacy manuals.
From the parts lists in the Enviro DV50DX manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Ceramic fan temperature sensor, 120°F (49°C) | EC-001 | $77.79 CAD → |
| 2 | S.I.T. Nova valve, convertible | 50-1421 | Request it |
| 3 | Thermocouple | EC-009 | Request it |
| 3 | Spark electrode with ignitor cable | EC-011 | $72.73 CAD → |
| 3 | Thermopile | EC-012 | $88.33 CAD → |
| 3 | Pilot orifice, natural gas, threaded | EC-019 | $61.62 CAD → |
| 3 | Pilot orifice, propane, threaded | EC-020 | $72.00 CAD → |
| 3 | Pilot gasket | EC-021 | $24.44 CAD → |
| 4 | S.I.T. piezo ignitor | EC-023 | $44.25 CAD → |
| 5 | Burner switch | EC-025 | $38.80 CAD → |
| 6 | Fan controller, 115 V | EC-039 | Request it |
| – | Domestic power cord, 115 V | EC-042 | $55.38 CAD → |
| – | S.I.T. pilot 1/8" tube with end ferrules | 30-043 | $59.75 CAD → |
| – | Termination cap | 50-018 | Request it |
| 7 | Blank orifice #73 | 50-343 | $35.47 CAD → |
| – | Embers (order 2 sets) | 50-491 | Request it |
| 8 | Convection blower, 115 V | 50-514 | $595.00 CAD → |
| 9 | Door latch mechanism (requires 2 sets) | 50-632 | Request it |
| 10 | Door handle set (requires 2 sets) | 50-635 | Request it |
| 11 | Dual bulb door gasket, 10 ft (3.05 m) | 50-634 | $68.00 CAD → |
| 11 | Door, glass and gasket | 50-718 | Request it |
| 12 | Pan burner only | 50-719 | Request it |
| 13 | Control panel | 50-726 | Request it |
| 14 | Burner tray assembly, complete | 50-727 | Request it |
| 15 | Ceramic brick liner | 50-728 | Request it |
| 16 | Grate | 50-729 | Request it |
| 17 | Andiron | 50-730 | Request it |
| – | Log set with embers | 50-731 | Request it |
| – | Owner's manual (listed as "DV42DX Owner's Manual") | 50-741 | Request it |
| – | Large ember nuggets only | 50-832 | Request it |
| 18 | Three flame pilot hood | 50-925 | $9.00 CAD → |
| – | Conversion kit, propane to natural gas (convertible valve) | 50-1428 | Request it |
| – | Conversion kit, natural gas to propane (convertible valve) | 50-1429 | Request it |
| – | S.I.T. valve conversion screw with O-ring | 50-1450 | Request it |
| – | S.I.T. valve conversion screw cap | 50-1451 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | The Lodge face, painted black with plated brushed nickel louvres and knobsoption | 50-702 | Request it |
| 2 | The Chalet flat arched face, painted blackoption | 50-703 | Request it |
| 2 | The Chalet flat arched face, plated goldoption | 50-704 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 2 | S.I.T. Nova valve, natural gas (50% turn down) | EC-006 | Request it |
| 2 | S.I.T. Nova valve, propane (50% turn down) | EC-007 | Request it |
| – | Conversion kit, propane to natural gas | 50-742 | Request it |
Under the control panel. The label is attached to a rectangular metal sheet that is chained to the fireplace. The installer should also have recorded the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-11291, p. 5; C-11291, p. 43
The DV50DX is discontinued and Enviro lists every DV50DX manual as archived. The last edition is C-11291, dated April 4, 2007; it and C-11079 (from March 2006) cover fireplaces with the S.I.T. Nova convertible valve, part 50-1421. Fireplaces from 2003 to 2005 have a separate natural gas or propane valve (EC-006 or EC-007) and match C-10986, C-10767, C-10121 or C-10044 by date. The parts lists are in the back of each manual.
Source: Enviro C-11291, p. 43; C-11291, p. 36; C-10986, p. 35
The DV50DX has a standing pilot that you light by hand with the piezo ignitor. The pilot is on the right, behind the side log. The gas valve has a lockout that will not let the pilot relight until the thermocouple has cooled; if the knob does not pop up when released, stop and call your service technician or gas supplier. If the pilot does not stay lit after several tries, turn the knob to OFF and call them.
Source: Enviro C-11291, p. 6; C-11291, p. 7
The troubleshooting table points to the thermocouple circuit: the thermocouple may be loose at the back of the valve, the pilot flame may not be fully surrounding the thermocouple (gas pressure, pilot rate screw or a damaged pilot head), or the thermocouple may be weak (it must read more than 5 mV at the valve). If the pilot dies while you hold the knob in, there may be air in the gas line. If the pilot or burners have gone out on their own, open the glass door and wait 5 minutes to air out before relighting. Gas work is for a qualified service technician.
Source: Enviro C-11291, p. 35; C-11291, p. 2; C-11291, p. 6
The pilot must be lit and the gas control knob must be at ON, not PILOT or OFF. If you use the optional remote or wall thermostat, leave the ON/OFF switch on the control panel in the remote/thermostat position, and check the remote batteries. If a thermostat is fitted, set it several degrees above room temperature. If the burner still won't light, the troubleshooting table has voltage checks on the valve and thermopile for a service technician.
Source: Enviro C-11291, p. 35; C-11291, p. 8
The blower comes on by itself once the fireplace is up to temperature, about 20 minutes. Turn the fan control knob to change its speed, or counter-clockwise until it clicks to turn it off. Enviro advises not running the blower below 1/3 speed, as it strains the windings and can cause early fan failure. The air diverter lever above the right end of the control panel sends the air to the room (far left), out the duct (far right) or both (middle). The blower moves 200 cfm however many ducts are used.
Source: Enviro C-11291, p. 8; C-11291, p. 7; C-11291, p. 28
To reach the blower, the brick liners, control panel, burner, air deflector and valve tray come out first. The convection blower is part 50-514 (115 V). The manual says repair should be done by a qualified service person; turn off the gas and the electrical power and let the fireplace go completely cold first.
Source: Enviro C-11291, p. 11; C-11291, p. 36; C-11291, p. 2; C-11291, p. 8
Condensation on a cold start is normal and clears as the fireplace warms, though it lets dust and lint cling to the glass. Additives in the gas can also leave a haze, and the first paint cure leaves a film, so clean the glass about two weeks after installation, then no more than two or three times a season depending on use.
Source: Enviro C-11291, p. 9; C-11291, p. 10; C-11291, p. 35
Stop using the fireplace: do not operate it with the glass removed, cracked or broken. The glass is a high temperature ceramic and needs a factory replacement bought from an Enviro dealer; no substitute materials are allowed, and removing and replacing the glass in the door must be done by a licensed or qualified service person. Wear gloves when handling a damaged door. The parts list gives 50-718 for the door, glass and gasket and 50-634 for the dual bulb door gasket.
Source: Enviro C-11291, p. 9; C-11291, p. 36
Only with a certified conversion kit installed by a qualified service agency. On the convertible valve, the kit holds a burner orifice (#30 DMS natural gas, #47 DMS propane), a pilot injector (0.62 mm natural gas, 0.35 mm propane), an instruction sheet and a conversion label. The installer changes the burner orifice and pilot injector, flips the valve's conversion screw (red O-ring visible for propane), leak-tests every joint with soapy water, checks the flame on HI and LO and fixes the conversion label on or near the rating label. The parts list gives 50-1429 for natural gas to propane and 50-1428 for propane to natural gas. On earlier fireplaces with a separate natural gas or propane valve, the conversion changes the valve's HI/LO regulator instead.
Source: Enviro C-11291, p. 12; C-11291, p. 13; C-11291, p. 36; C-10986, p. 11
At least once a year, have a qualified service person check that every burner port is clear and clean and that nothing blocks the pilot; the pilot flame should be blue with little or no yellow on the tips. The venting system should be examined periodically, ideally by a qualified agency. When cleaning the firebox, lift the fragile logs out, set the embers and rock wool aside, vacuum the firebox floor, clean the dust off the logs and the lint from the burner and pilot, and check the burner pan for cracking or warping. A little soot on the underside of the logs is normal.
Source: Enviro C-11291, p. 9; C-11291, p. 2
Sale price $61.62 CAD Regular price $67.99 CAD
| 2 | The Chalet flat arched face, plated brushed nickeloption | 50-705 | Request it |
| 2 | The Chalet flat arched face, plated antique copperoption | 50-706 | Request it |
| 3 | The Cottage bow face, painted black (no trim)option | 50-707 | Request it |
| – | The Cottage trim kit, painted black (inset piece, carriage bolts, top and bottom trim)option | 50-708 | Request it |
| – | The Cottage trim kit, antique copper (inset piece, carriage bolts, top and bottom trim)option | 50-709 | Request it |
| – | The Cottage trim kit, pewter (inset piece, carriage bolts, top and bottom trim)option | 50-710 | Request it |
| – | The Cottage trim kit, gold (inset piece, carriage bolts, top and bottom trim)option | 50-711 | Request it |
| 4 | The Cape Cod arch with opening doors and fire screen, paintedoption | 50-712 | Request it |
| – | On/off remote control kitoption | 50-559 | Request it |
| – | Programmable wall mounted remote controloption | 50-583 | Request it |
| – | The Lodge steel templateoption | 50-725 | Request it |
| – | The Chalet steel templateoption | 50-722 | Request it |
| – | The Cottage steel templateoption | 50-723 | Request it |
| – | The Cape Cod steel templateoption | 50-724 | Request it |
| – | Conversion kit, natural gas to propane | 50-1034 | Request it |