Manuals & parts · Direct vent gas fireplace (discontinued)
Quick answer
The Enviro DV42DX (DV42) is a discontinued direct vent gas fireplace, and Enviro lists all of its manuals as archived. The last owner's manual is C-13826, dated January 22, 2013, a free PDF from enviro.com; fireplaces from 2003 to early 2006 have a different gas valve and match the earlier editions by date. DV42 parts are still sold here, and the rating label is under the control panel, on a metal sheet chained to the fireplace.
Every DV42DX owner's manual Enviro still publishes, the factory parts lists with part numbers (valve, pilot parts, blower, door and glass, burner, logs and the optional faces), key specs, and answers to common DV42DX questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the DV42DX, but we still sell its parts.
Last updated · From Enviro docs C-13826, C-10915 and C-10117 · Answers drafted from the manuals; staff review pending
DV42DX (2006 to 2013 manuals)
Direct vent gas fireplace with a hand-lit standing pilot and piezo ignitor, a burner switch and HI/LO knob, a convection blower with a variable fan control, and an air diverter that sends the blower air to the room, to a duct or both. It has the S.I.T. Nova convertible valve: a fuel conversion changes the burner orifice and pilot injector and flips the valve's conversion screw. The 2010 and 2013 editions add the Carriage House and Townhouse faces to the options.
Manuals: C-13826, C-11278, C-11078
DV42DX (2003 to 2006 manuals)
Earlier fireplaces with a separate S.I.T. Nova valve for natural gas or for propane (50% turn down). The first edition, from November 2003, also lists the logs one by one and a fully assembled pilot for each gas. Use the edition whose date matches your installation.
Manuals: C-10915, C-10761, C-10117
Find your model and serial number: The rating label is under the control panel, attached to a rectangular metal sheet that is chained to the fireplace. (Enviro C-13826, p. 5)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro DV42DX is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro DV42DX parts.
DV42DX Owner's Manual
C-13826 · Jan 22, 2013 – Present
DV42DX Owner's Manual
C-11278 · Jun 28, 2010 – Jan 22, 2013
DV42DX Owner's Manual
C-11078 · Mar 20, 2006 – Jun 28, 2010
DV42DX Owner's Manual
C-10915 · Oct 3, 2005 – Mar 20, 2006
DV42DX Owner's Manual
C-10761 · Nov 26, 2004 – Oct 3, 2005
DV42DX Owner's Manual
C-10117 · Nov 19, 2003 – Nov 26, 2004
Can't open a link? Enviro lists every version on its manuals pages: Enviro DV42DX manuals, Enviro legacy manuals.
From the parts lists in the Enviro DV42DX manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Ceramic fan temperature sensor, 120°F (49°C) | EC-001 | $77.79 CAD → |
| 2 | S.I.T. Nova valve, convertible | 50-1421 | Request it |
| 3 | Thermocouple | EC-009 | Request it |
| 3 | Spark electrode with ignitor cable | EC-011 | $72.73 CAD → |
| 3 | Thermopile | EC-012 | $88.33 CAD → |
| 3 | Pilot orifice, natural gas, threaded | EC-019 | $61.62 CAD → |
| 3 | Pilot orifice, propane, threaded | EC-020 | $72.00 CAD → |
| 3 | Pilot gasket | EC-021 | $24.44 CAD → |
| 4 | S.I.T. piezo ignitor | EC-023 | $44.25 CAD → |
| 5 | Burner switch | EC-025 | $38.80 CAD → |
| 6 | Fan controller, 115 V | EC-039 | Request it |
| – | Domestic power cord, 115 V | EC-042 | $55.38 CAD → |
| – | S.I.T. pilot 1/8" tube with end ferrules | 30-043 | $59.75 CAD → |
| – | Termination cap | 50-018 | Request it |
| 7 | Blank orifice #73 | 50-343 | $35.47 CAD → |
| – | Embers (order 2 sets) | 50-491 | Request it |
| 8 | Convection blower, 115 V | 50-514 | $595.00 CAD → |
| 9 | Ceramic brick liner | 50-628 | Request it |
| 10 | Pan burner only | 50-629 | Request it |
| 11 | Grate | 50-630 | Request it |
| 12 | Andiron | 50-631 | Request it |
| 13 | Door latch mechanism | 50-632 | Request it |
| 14 | Door, glass and gasket | 50-633 | Request it |
| 14 | Dual bulb door gasket, 10 ft (3.05 m) | 50-634 | $68.00 CAD → |
| 15 | Door handle set | 50-635 | Request it |
| 16 | Control panel | 50-636 | Request it |
| 17 | Burner tray assembly, complete | 50-637 | Request it |
| – | Log set with embers | 50-638 | Request it |
| – | DV42DX owner's manual | 50-645 | Request it |
| – | Conversion kit, propane to natural gas | 50-647 | Request it |
| – | Conversion kit, natural gas to propane | 50-756 | Request it |
| – | Large ember nuggets only | 50-832 | Request it |
| 18 | Three flame pilot hood | 50-925 | $9.00 CAD → |
| – | Conversion kit, propane to natural gas (convertible valve) | 50-1426 | Request it |
| – | Conversion kit, natural gas to propane (convertible valve) | 50-1427 | Request it |
| – | S.I.T. valve conversion screw with O-ring | 50-1450 | Request it |
| – | S.I.T. valve conversion screw cap | 50-1451 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | The Lodge face, painted charcoal with plated brushed nickel louvres and knobsoption | 50-534 | Request it |
| – | The Manor cast iron bay face, paintedoption | 50-537 | Request it |
| 2 | The Manor cast iron bay face, diamond blackoption | 50-539 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 2 | S.I.T. Nova valve, natural gas (50% turn down) | EC-006 | Request it |
| 2 | S.I.T. Nova valve, propane (50% turn down) | EC-007 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| – | Fully assembled pilot, natural gas | EC-015 | $141.60 CAD → |
| – | Fully assembled pilot, propane | EC-016 | Request it |
| – | Back log | 50-639 | Request it |
| – | Left log | 50-640 |
Under the control panel. The rating label is attached to a rectangular metal sheet that is chained to the fireplace. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-13826, p. 5; C-13826, p. 40
The DV42DX is discontinued and Enviro lists every DV42DX manual as archived. The last edition is C-13826, dated January 22, 2013; it, C-11278 (from June 2010) and C-11078 (from March 2006) cover fireplaces with the S.I.T. Nova convertible valve, part 50-1421. Fireplaces from 2003 to early 2006 have a separate natural gas or propane valve (EC-006 or EC-007) and match C-10915, C-10761 or C-10117 by date. The parts lists are at the back of each manual.
Source: Enviro C-13826, p. 40; C-13826, p. 35; C-10915, p. 34
The DV42DX has a standing pilot that you light by hand with the piezo ignitor. The pilot is on the right, behind the side log. The gas valve has a lockout device that will not let the pilot relight until the thermocouple has cooled; if the knob does not pop up when released, stop and call your service technician or gas supplier. If the pilot does not stay lit after several tries, turn the knob to OFF and call them.
Source: Enviro C-13826, p. 6; C-13826, p. 7
The troubleshooting table points to the thermocouple circuit: the thermocouple may be loose at the back of the valve, the pilot flame may not be fully surrounding the thermocouple (gas pressure, pilot rate screw or a damaged pilot head), or the thermocouple may be weak (it must read greater than 5 mV at the valve). If the pilot dies while you hold the knob in, there may be air in the gas line. If the pilot or burners have gone out on their own, open the glass door and wait 5 minutes to air out before relighting. Gas work is for a qualified service technician.
Source: Enviro C-13826, p. 34; C-13826, p. 2
The pilot must be lit and the gas control knob must be at ON, not PILOT or OFF. The DV42DX can use an optional remote control or cordless wall thermostat; if you use one most of the time, leave the ON/OFF switch on the control panel in the remote/thermostat position, and check the remote batteries. If a thermostat is fitted, set it several degrees above room temperature. If the burner still won't light, the troubleshooting table has voltage checks on the valve and thermopile for a service technician. The options list gives 50-559 for the on/off remote control kit and 50-583 for the programmable wall mounted remote.
Source: Enviro C-13826, p. 34; C-13826, p. 8; C-13826, p. 37
The blower comes on by itself once the fireplace is up to temperature, about 20 minutes. Turn the fan control knob to change its speed, or counter-clockwise until it clicks to turn it off. Enviro advises not running the blower below 1/3 speed, as it strains the windings and can cause early fan failure. The air diverter lever above the right end of the control panel sends the air to the room (far left), out the duct (far right) or both (middle). The blower moves 200 cfm however many ducts are used, so the more ducts there are, the less air goes through each one.
Source: Enviro C-13826, p. 8; C-13826, p. 7; C-13826, p. 28
To reach the blower, the brick liners, control panel, burner, air deflector and valve tray come out first. The convection blower is part 50-514 (115 V). The manual says repair should be done by a qualified service person; turn off the gas and the electrical power and let the fireplace go completely cold first.
Source: Enviro C-13826, p. 11; C-13826, p. 35; C-13826, p. 2; C-13826, p. 8
Condensation on a cold start is normal and clears as the fireplace warms, though it lets dust and lint cling to the glass. Additives in the gas can also leave a haze, and the first paint cure leaves a film, so clean the glass about two weeks after installation, then no more than two or three times a season depending on use.
Source: Enviro C-13826, p. 9; C-13826, p. 10; C-13826, p. 34
Stop using the fireplace: do not operate it with the glass front removed, cracked or broken. The glass is a high temperature ceramic and needs a factory replacement bought from an Enviro dealer; no substitute materials are allowed, and removing and replacing the glass in the door must be done by a licensed or qualified service person. Wear gloves when handling a damaged door. The parts list gives 50-633 for the door, glass and gasket and 50-634 for the dual bulb door gasket.
Source: Enviro C-13826, p. 9; C-13826, p. 35
Only with a certified conversion kit installed by a qualified service agency. On the convertible valve, the kit holds a burner orifice, a pilot injector (0.62 mm natural gas, 0.35 mm propane), an instruction sheet and a conversion label. The installer removes the burner, changes the burner orifice and pilot injector, flips the valve's conversion screw (red O-ring visible for propane), leak-tests every gas joint with soapy water, checks the flame on HI and LO and fixes the conversion label on or near the rating label. The parts list gives 50-1427 for natural gas to propane and 50-1426 for propane to natural gas on the convertible valve, and also lists kits 50-756 and 50-647.
Source: Enviro C-13826, p. 1; C-13826, p. 12; C-13826, p. 13; C-13826, p. 35
Not if the fireplace sits 3 inches (76 mm) or more above the floor, measured from the top of the flooring (the top of the carpet, for example). Below that, a hearth is mandatory: a sheet metal protector pad directly on the floor or hearth framing, cement board on top of it, and tile or another non-combustible material as the top layer. The Manor cast iron face does not need any floor protection, even at floor level. A raised fireplace cannot be within 41 inches (1041 mm) of the ceiling. Installation is for qualified installers.
Source: Enviro C-13826, p. 15; C-13826, p. 16
The manual asks for an inspection before first use and at least once a year by a qualified service person, with more frequent cleaning if there is a lot of lint from carpets or bedding. Each year check that every burner port is clear and clean and that nothing blocks the pilot; the pilot flame should be blue with little or no yellow on the tips. Have the venting system examined periodically, ideally by a qualified agency. Once a year, lift the fragile logs out and check them for deterioration or heavy soot; a little soot on their underside is normal. When cleaning the firebox, set the embers and rock wool aside, vacuum the firebox floor, clean dust off the logs and lint from the burner and pilot, and check the burner pan for cracking or warping.
Source: Enviro C-13826, p. 2; C-13826, p. 9; C-13826, p. 31
Sale price $61.62 CAD Regular price $67.99 CAD
| 3 | The Chalet flat arched face, paintedoption | 50-541 | Request it |
| – | The Chalet flat arched face, plated goldoption | 50-542 | Request it |
| – | The Chalet flat arched face, plated brushed nickeloption | 50-543 | Request it |
| – | The Chalet flat arched face, plated antique copperoption | 50-608 | Request it |
| – | The Cottage bow face, painted black (no trim)option | 50-693 | Request it |
| – | The Cottage trim kit, gold (inset piece, carriage bolts, top and bottom trim)option | 50-548 | Request it |
| 4 | The Cottage trim kit, pewter (inset piece, carriage bolts, top and bottom trim)option | 50-549 | Request it |
| – | The Cottage trim kit, antique copper (inset piece, carriage bolts, top and bottom trim)option | 50-550 | Request it |
| – | The Cottage trim kit, painted black (inset piece, carriage bolts, top and bottom trim)option | 50-694 | Request it |
| 5 | The Cape Cod arch with opening doors and fire screen, paintedoption | 50-553 | Request it |
| – | On/off remote control kitoption | 50-559 | Request it |
| – | Programmable wall mounted remote controloption | 50-583 | Request it |
| – | Cast iron firebox liner set, porcelain blackoption | 50-609 | Request it |
| – | The Lodge steel templateoption | 50-614 | Request it |
| – | The Manor steel templateoption | 50-615 | Request it |
| – | The Chalet steel templateoption | 50-616 | Request it |
| – | The Cottage steel templateoption | 50-617 | Request it |
| – | The Cape Cod steel templateoption | 50-618 | Request it |
| 6 | Carriage House face, blackoption | 50-1534 | Request it |
| – | Townhouse face, blackoption | 50-1535 | Request it |
| 7 | Townhouse face, nickeloption | 50-1543 | Request it |
| – | Townhouse face, copperoption | 50-1544 | Request it |
| Request it |
| – | Left/center log | 50-641 | Request it |
| – | Center log | 50-642 | Request it |
| – | Right log | 50-643 | Request it |
| – | Two small log twigs | 50-644 | Request it |