Manuals & parts · Direct vent freestanding gas stove (discontinued)
Quick answer
The Enviro Cara is a discontinued direct vent freestanding gas stove, and Enviro lists all of its manuals as archived. The last editions, both dated June 28, 2010 and free PDFs from enviro.com, are C-11499 for the Cara (top or rear vent) and C-11500 for the Cara DR, the rear-vent-only version. Cara parts are still sold here, and the rating label is on the inside of the pedestal control door.
Every Cara and Cara DR owner's manual Enviro still publishes, the factory parts list with part numbers (valve, pilot, burners, log and rock sets, door and glass, castings and fan kit), key specs and answers to common owner questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the Cara, but we still sell its parts.
Last updated · From Enviro docs C-11499 and C-11500 · Answers drafted from the manuals; staff review pending
Cara (top vent)
Ships as a 33,500 Btu/h top-vented freestanding stove for vertical or horizontal terminations, with an add-in vent restrictor chosen by vent length. S.I.T. Nova millivolt valve with a piezo ignitor, natural gas or propane, log set or rock set.
Manuals: C-11499, C-11436, C-11316
Cara (rear vent)
The same stove with its flue elbow turned 180° to the rear; it must be used with a 36 inch snorkel termination and a horizontal run of no more than 36 inches. Covered by the Cara manuals.
Manuals: C-11499, C-11436, C-11316
Cara DR
Rear-vent-only version for short horizontal installations (maximum 2 ft run, no elbows, no restrictor, optional 14 or 36 inch snorkel), with smaller main burner orifices for a 26,000 Btu/h maximum input. Ships as a top-vented Cara and is converted at installation.
Manuals: C-11500, C-11366
Find your model and serial number: The rating label is on the inside surface of the pedestal control door. (Enviro C-11499, p. 5)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro Cara is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro Cara parts.
Can't open a link? Enviro lists every version on its manuals pages: Enviro Cara manuals, Enviro legacy manuals.
From the parts lists in the Enviro Cara manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | 120°F (49°C) ceramic fan temperature sensor | EC-001 | $77.79 CAD → |
| – | Thermopile | EC-012 | $88.33 CAD → |
| 2 | S.I.T. piezo igniter | EC-023 | $44.25 CAD → |
| – | Domestic power cord, 115V | EC-042 | $55.38 CAD → |
| – | Heyco strain relief | EC-044 | $73.29 CAD → |
| 3 | Convection blower (fan), 115V | EC-069 | $293.33 CAD → |
| 3 | Cara fan kitoption | 50-1545 | Request it |
| 4 | Fan controller with knob, 115V | EF-045 | $40.00 CAD → |
| – | Dual bulb door gasket, 10 ft (3.05 m) | 50-634 | $68.00 CAD → |
| 5 | S.I.T. Nova valve, convertible | 50-1421 | Request it |
| 5 | S.I.T. valve conversion screw with O-ring | 50-1450 | Request it |
| 5 | S.I.T. valve conversion screw cap | 50-1451 | Request it |
| 5 | Cara valve tray assembly | 50-1604 | Request it |
| 6 | Cara firebox liner, ceramicoption | 50-1546 | Request it |
| 7 | Cara log set and burner | 50-1563 | Request it |
| – | Cara rock set and burner | 50-1564 | Request it |
| – | Proflame programmable thermostat remote control system, NGoption | 50-1570 | Request it |
| – | Proflame programmable thermostat remote control system, LPoption | 50-1571 | Request it |
| – | Cara log set only | 50-1600 | Request it |
| – | Cara rock set only | 50-1601 | Request it |
| 7 | Cara log set burner only | 50-1602 | Request it |
| – | Cara rock set burner only | 50-1603 | Request it |
| – | Cara conversion kit, LP to NG, convertibleoption | 50-1591 | Request it |
| – | Cara conversion kit, NG to LP, convertibleoption | 50-1592 | Request it |
| 8 | Cara door assembly | 50-1593 | Request it |
| 8 | Cara glass with gasket, 14½" x 16¾" (368 x 425 mm) | 50-1613 | Request it |
| 9 | Cara door latch assembly | 50-1594 | Request it |
| 10 | Cara main orifice, NG (PO512-37) | 50-1596 | Request it |
| 10 | Cara main orifice, LPG (PO512-1/16") | 50-1597 | Request it |
| 11 | Cara flue outlet elbow and gasket | 50-1598 | Request it |
| 11 | Cara flue outlet gasket only | 50-1599 | Request it |
| 12 | Cara PSE pilot assembly (PSE-C3-505) | 50-1605 | $176.00 CAD → |
| 12 | Cara PSE thermocouple (#019G) | 50-1612 | Request it |
| 13 | Cara cast insert, rear vent | 50-1606 | Request it |
| 14 | Cara cast insert, top vent | 50-1607 | Request it |
| 15 | Cara cast stove top | 50-1608 | Request it |
| 16 | Cara cast louvers | 50-1609 | Request it |
| 17 | Cara cast stove bottom | 50-1610 | Request it |
| – | Cara leveling legs (set of 4) | 50-1611 | Request it |
| 18 | Cara vent restrictor, set of 4 (50%, 60%, 70%, 75%) | 50-1616 | Request it |
| 19 | Pedestal glass door assembly with magnet brackets | 50-1621 | Request it |
| 20 | Cabinet side, left and right | 50-1622 | Request it |
| 21 | Cabinet side hangers (set of 4) | 50-1623 | Request it |
| 22 | Louver brackets, left and right | 50-1624 | Request it |
| 23 | Cara firebox liner, steel | 50-1627 | Request it |
| – | Cara owner's manual | 50-1630 | Request it |
| 24 | Cara stove back | 50-1707 | Request it |
| 25 | Cara burner switch | 50-1617 | Request it |
| 26 | Cara switch box | 50-1708 | Request it |
| 26 | Cara pedestal door magnet | 50-1709 | Request it |
| 27 | Cara control panel | 50-1710 | Request it |
| 28 | Cara firebox baffle | 50-1740 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 17 | Cara DR owner's manual and main orifices, NG (PO512-42) and LPG (PO512-54) | 50-1628 | Request it |
On the inside surface of the pedestal control door, on both the Cara and the Cara DR. It shows the gas type the stove is set up for; if the stove has been converted to the other gas, a conversion label should be on or close to the rating label. Your installer should also have recorded the model, serial number, gas type and orifice sizes on the installation data sheet at the back of the owner's manual.
Source: Enviro C-11499, p. 5; C-11500, p. 5; C-11499, p. 1; C-11499, p. 4; C-11499, p. 13; C-11499, p. 46
Enviro lists every Cara manual as archived. For a Cara (top vented, or rear vented with a 36 inch snorkel) use C-11499, listed from June 28, 2010; C-11436 (October 15, 2007 to June 28, 2010) and C-11316 (August 15 to October 15, 2007) are earlier editions. For the Cara DR, the rear-vent-only version, use C-11500, listed from June 28, 2010; C-11366 (October 15, 2007 to June 28, 2010) is the earlier DR edition. The Cara parts list is on pages 40 and 41 of C-11499; the DR list is on pages 31 and 32 of C-11500.
Source: Enviro C-11499, p. 1; C-11500, p. 1; C-11500, p. 15; C-11499, p. 40; C-11499, p. 41; C-11500, p. 31; C-11500, p. 32
The Cara has a standing pilot that you light by hand with the gas control knob and the piezo ignitor. Before lighting, smell all around the stove and near the floor for gas; if you smell gas, do not light anything and call your gas supplier from a neighbour's phone. The valve has a lockout, so after the pilot goes out it cannot be relit until the thermocouple has cooled. If the knob does not pop up when released, or the pilot will not stay lit after several tries, turn the knob to OFF and call a service technician or your gas supplier. To shut the stove off, flip the burner switch to OFF and turn the gas control knob clockwise to OFF.
Source: Enviro C-11499, p. 6
If the pilot or burners go out on their own, open the glass door and wait 5 minutes to air out before relighting. The troubleshooting chart lists the usual causes. A pilot that will not stay lit points to the thermocouple circuit (a loose connection at the valve, a pilot flame too small to wrap the thermocouple, or a thermocouple reading under 5 mV) or to air in the gas line. A burner that will not stay lit points to the thermopile circuit: gas pressure, the pilot flame on the thermopile, a thermopile under 300 mV with the burner on, or broken thermostat wiring. These checks need a meter and gas pressure testing, so have a qualified service technician do them.
Source: Enviro C-11499, p. 2; C-11499, p. 39
Yes. The Cara has a millivolt gas control that uses the pilot flame to make enough electricity to run the main burner, so it operates without electrical power, and the pilot is lit with a piezo ignitor. The optional blower does need power: it plugs into a grounded three-prong outlet.
Source: Enviro C-11499, p. 30; C-11499, p. 6; C-11499, p. 31
The remote and the cordless wall thermostat are options. If one does not work, check the remote's batteries first, then the stove: the ON/OFF burner switch must be ON, the gas control valve must be at ON rather than PILOT or OFF, and the pilot must be lit. If you use the remote or a wall thermostat most of the time, leave the ON/OFF switch in the ON position, and follow the instructions that came with the remote. The Proflame programmable thermostat remote was sold as 50-1570 for natural gas and 50-1571 for propane.
Source: Enviro C-11499, p. 39; C-11499, p. 8; C-11499, p. 40
Clean the glass with the stove off and cold, using a gas fireplace glass cleaner from your Enviro dealer. Enviro says to do this after the first burn: run the stove on high without the fan for the first 4 hours to cure the paint, logs and gasket, let it go cold, then take the door off and clean the glass. Fogging on a cold start is normal and clears as the stove warms; additives in the gas can also leave a haze, so clean it as needed. Make sure the door is properly hooked on before lighting the stove again.
Source: Enviro C-11499, p. 4; C-11499, p. 9; C-11499, p. 39
Do not run the stove with the glass removed, cracked or broken. The glass is a high temperature ceramic, and if it is damaged in any way the manual calls for a factory replacement door (Cara door assembly, 50-1593); the parts list also has the Cara glass with gasket, 14½" x 16¾", as 50-1613. Removing and replacing the glass in the door must be done by a licensed or qualified service person, and the door must come from an Enviro dealer. Wear gloves when handling a damaged glass door.
Source: Enviro C-11499, p. 10; C-11499, p. 40
Yes, with Enviro's conversion kit, installed by a qualified service agency only: 50-1592 for natural gas to propane and 50-1591 for propane to natural gas. The kit holds the main burner orifice (NG PO512-37 DMS or LP PO512-1/16" DMS) and an instruction sheet. The conversion swaps the burner orifice, moves the pilot injector tab to the other gas position and flips the S.I.T. valve conversion screw (the red O-ring shows for propane), then the joints are leak tested with soapy water and a conversion label goes on or close to the rating label. A Cara DR uses its own orifices, PO512-42 for natural gas and PO512-54 for propane.
Source: Enviro C-11499, p. 12; C-11499, p. 13; C-11499, p. 40; C-11500, p. 20
Have it inspected before first use and at least annually by a qualified service person, who should also examine the venting. At least once a year check that every burner port is clear, that nothing blocks the pilot, and that the pilot flame is blue with little or no yellow on the tips, and wipe the painted surfaces with a damp cloth periodically. Clean the firebox with the stove at room temperature, and keep the control compartment, burner and air passages clean, since lint from carpets and bedding can build up.
Source: Enviro C-11499, p. 2; C-11499, p. 9; C-11499, p. 10
Both are direct vent: all combustion air comes from outside through the vent pipe, so venting must be installed by a qualified installer with an approved 4" x 6 5/8" direct vent system. The Cara ships as a 33,500 Btu/h top-vented stove for vertical or horizontal terminations, with a vent restrictor chosen from the vent-length charts. It can be turned into a rear-vented stove, which must use a 36" snorkel and a horizontal run of no more than 36". The Cara DR is for horizontal rear venting only: a run of at most 2' (61 cm) rising 1¼" per foot, no elbows and no restrictor, with a 14" or 36" snorkel if needed to clear grade, and it needs the DR main burner orifice.
Source: Enviro C-11499, p. 4; C-11499, p. 16; C-11499, p. 19; C-11499, p. 27; C-11500, p. 15; C-11500, p. 17
Sale price $55.38 CAD Regular price $60.99 CAD