Enviro's current C72 documents are C-17434, the C72I-4 owner's and installation manual, and C-17221, the C-Series User Manual that explains the Proflame 2 remote. Both are free PDFs on enviro.com. Older C72I and C72I-3 fireplaces have archived owner's manuals dated from May 2020. The rating label with the model and serial number hangs on a chain inside the cabinet, at the front left, behind the safety screen.
The C72 owner's and installation manuals Enviro lists since 2020, the remote user manual, the factory parts list with part numbers, key specs, and common owner questions answered from the manuals with page numbers.
Last updated · From Enviro docs C-17434 rev R00 and C-17221 · Answers drafted from the manuals; staff review pending
C72I (2020 to 2025)
Earlier C72I owner's manuals, listed on enviro.com from May 19, 2020 to March 17, 2025.
Manuals: C-15685, C-16246, C-16991
C72I-3
Owner's manual C-17220, listed March 18, 2025 to January 21, 2026. The C-Series User Manual (C-17221) for the Proflame 2 remote is listed from the same date.
Manuals: C-17220, C-17221
C72I-4
Current model, owner's manual listed from January 22, 2026. Intermittent pilot ignition (IPI) run by the Proflame 2 remote and controller, with an optional dual convection fan kit. Full remote instructions are in the C-Series User Manual.
Manuals: C-17434, C-17221
Find your model and serial number: Rotate the safety screen upward or remove it completely. The rating label and lighting instruction plates are on a length of chain inside the cabinet, on the left side near the front. Never tamper with or remove them: the label carries the model-specific serial number you need for warranty information. (Enviro C-17434, p. 7)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
C72I-4 Owner's Manual R00
C-17434 rev R00 · Jan 22, 2026 – Present · 64 pages · Current
C-Series User Manual
C-17221 · Mar 18, 2025 – Present · 14 pages · Current
C72I-3 Owner's Manual R02
C-17220 rev R02 · Mar 18, 2025 – Jan 21, 2026
C72I Owner's Manual R04
C-16991 rev R04 · Feb 1, 2024 – Mar 17, 2025
C72I Owner's Manual R03
C-16246 rev R03 · Dec 1, 2021 – Jan 31, 2024
C72I Owner's Manual R01
C-16246 rev R01 · Jun 1, 2021 – Dec 1, 2021
C72I Owner's Manual
C-15685 · May 19, 2020 – June 1, 2021
Cool Surface System Front Vent Instruction Manual R3
C-15843 rev R3 · Sep 1, 2019 – Apr 1, 2022
Cool Surface System Front Vent Instruction Manual R1
C-15204 rev R1 · Oct 10, 2017 – Sept 1, 2019
Can't open a link? Enviro lists every version on its manuals pages: Enviro C72 manuals.
From the parts lists in the Enviro C72 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | C72 pan burner | 50-3696 | $361.67 CAD → |
| 2 | C72 door complete | 50-3697 | Request it |
| 3 | C72-3 safety screen complete | 50-4706 | Request it |
| 4 | C72 clear view screen only | 50-3700 | $426.00 CAD → |
| 5 | C72 Borderview surround, powder coated greyoption | 50-3692 | Request it |
| 5 | C72 Borderview surround, nickel platedoption | 50-3693 | Request it |
| 6 | C72 door glass with gasket | 50-3698 | Request it |
| 7 | S.I.T. 885 valve with NG stepper motor | 50-2682 | $270.00 CAD → |
| 8 | Proflame 2 IFC (controller), 0.584.625 | 50-4103 | $330.77 CAD → |
| 9 | IPI NG pilot assembly (2021) | 50-4058 | $120.00 CAD → |
| – | IPI LP pilot thimble (2021) | 50-4080 | $22.00 CAD → |
| 10 | C72 glass bezeloption | 50-3856 | Request it |
| 12 | IPI dual convection fan kit, 240 CFM combinedoption | 50-3760 | Request it |
| – | C72 fan only | 50-3798 | $114.00 CAD → |
| 13 | C72 fluted linersoption | 50-3685 | Request it |
| 13 | C72 ledgestone linersoption | 50-3686 | $1,397.45 CAD → |
| 13 | C72 porcelain linersoption | 50-3687 | $788.73 CAD → |
| 14 | C72 ultra high definition driftwood log setoption | 50-3691 | $1,257.82 CAD → |
| – | C72 black glass beadsoption | 50-3688 | Request it |
| – | C72I LP to NG fuel conversion kitoption | 50-3695 | Request it |
| – | C72I NG to LP fuel conversion kit (stepper motor only)option | 50-3753 | $187.20 CAD → |
| – | C72 vermiculite, 3 cups | 50-3702 | Request it |
| – | C72I owner's manual | 50-3703 | Request it |
| – | C/G Series power vent kitoption | 50-3884 | $2,018.40 CAD → |
| – | Metallic black touch-up paint, 12 oz can | PAINT-12-MB | Request it |
On the rating label. Rotate the safety screen upward or take it off completely; the rating label and lighting instruction plates hang on a chain inside the cabinet, on the left side near the front. Never tamper with or remove them. The label carries the model-specific serial number you need for warranty information.
Source: Enviro C-17434, p. 7
Check the model code on the rating label. The current owner's and installation manual is C-17434, for the C72I, an IPI fireplace run by the Proflame 2 remote system. For full remote instructions it refers you to the user manual supplied with the fireplace. The C-Series User Manual, C-17221, covers the Proflame 2 remote for C-Series fireplaces. Older C72I fireplaces have archived owner's manuals; the documents list above shows the dates each one covers.
Source: Enviro C-17434, p. 1; C-17434, p. 8; C-17434, p. 9; C-17221, p. 1; C-17221, p. 7
The C72I lights itself. Don't try to light the pilot by hand. Press ON/OFF on the remote; the controller beeps once and starts the ignition sequence by lighting the pilot first. The control tries several times to light the pilot if needed; if it can't, it stops. Below 50°F (10°C) outside, Enviro recommends continuous pilot (CPI) mode: the pilot stays lit, which keeps the chimney warm for a good draft at ignition and cuts condensation on the door glass. Switch to CPI with the MODE key while the fireplace is off.
Source: Enviro C-17434, p. 1; C-17434, p. 8; C-17221, p. 9
Start with the batteries. A battery icon shows on the remote when its three AAA batteries are low. The controller (IFC) has four AA backup batteries; when they are low it no longer beeps on an ON/OFF command. After replacing batteries, re-sync the remote with the red reset button on the IFC. If the remote still does nothing, check that you are not too far from the fireplace.
Source: Enviro C-17221, p. 7; C-17221, p. 8; C-17221, p. 9; C-17221, p. 11; C-17434, p. 57
When the maximum number of failed ignitions or flame restorations is reached, the fireplace stops reacting to commands. The manual says to remove any possible blocking conditions, then reset the Proflame IFC board with the steps below. If the remote and controller have lost communication, re-pair them as in the remote question above. Also check the remote batteries and that you are close enough to the fireplace.
Source: Enviro C-17434, p. 57; C-17434, p. 58
Yes, for a while. The C72I needs a hard-wired 120 V connection to operate, and it has a battery pack that takes four AA batteries in case there is a power loss. The controller can run off this battery backup for shorter periods of time. All electrical connections must be made by a certified electrician.
Source: Enviro C-17434, p. 51; C-17221, p. 8
Condensation on a cold start is normal with all fireplaces and clears as the fireplace warms. A haze from additives in the gas, or a film from the first paint cure, is also normal; the glass will need cleaning about two weeks after installation, then no more than two or three times a season. Clean only when the fireplace is cool, with a mild glass cleaner and a soft cloth. Abrasive cleaners damage the glass and painted surfaces.
Source: Enviro C-17434, p. 10; C-17434, p. 11; C-17434, p. 12; C-17434, p. 58
Stop using the fireplace: don't run it with the glass front removed, cracked or broken. A factory replacement from an Enviro dealer is required, no substitutes, and removal and replacement of the glass must be done by a licensed or qualified service person. The parts list gives 50-3698 for the door glass with gasket and 50-3697 for the complete door.
Source: Enviro C-17434, p. 3; C-17434, p. 10; C-17434, p. 60
Yes, with the conversion kit, installed by a qualified service agency or technician only. The kit has a burner orifice (NG #27 DMS or LP 2.3mm DMS), a pilot orifice, a stepper regulator with hardware, an instruction sheet and two conversion labels. The installer swaps the orifices and the valve's stepper motor, removes the 4 pieces of burner mesh for LP, leak-tests, checks gas pressures and fits a conversion label on or close to the rating label. The parts list gives 50-3753 for the NG to LP kit (stepper motor only) and 50-3695 for the LP to NG kit.
Source: Enviro C-17434, p. 14; C-17434, p. 15; C-17434, p. 60
Enviro says the Cool Surface System (CSS) should be activated, or an optional front or side CSS kit installed, to protect a TV or art above the fireplace. In Enviro's testing temperatures did not exceed 150°F (65°C) in a 5" deep recess. Leave 2" of clearance around the sides and top of the TV. With a mantel (at least 8" is highly recommended) the minimum from the base of the unit to the bottom of the TV is 45.75"; with a recess it is 47.00". Check your TV maker's maximum operating temperature and don't install the TV if temperatures exceed it.
Source: Enviro C-17434, p. 37; C-17434, p. 38