Quick answer

The current Enviro C44 manuals are C-17451 (C44I-4 owner's and installation manual) and C-17221 (C-Series User Manual, the Proflame 2 remote instructions shared with the C60), both free PDFs from enviro.com. A C44 without the I is the older millivolt model with a piezo ignitor, covered by the archived C44 manuals up to December 2021. The model and serial number are on the rating label on a chain inside the cabinet, left side near the front, behind the safety screen.

Owner's and installation manuals for every Enviro C44 and C60 version since 2016, the factory parts lists with part numbers, key specs, and answers to common C-Series questions, each taken from the official Enviro manual with the page number.

Last updated · From Enviro docs C-17451 rev R00, C-17470 rev R00, C-16998 rev R03, C-16242 rev R03, C-17221 and C-16244 rev R03 · Answers drafted from the manuals; staff review pending

Which Enviro C44 do I have?

C44 (millivolt)

Aug 2016 to Dec 2021. SIT Nova millivolt valve, powered by the pilot flame, with the pilot lit by a piezo ignitor. Runs without household power and must be wired to a wall switch or thermostat. An optional remote or cordless wall thermostat can be added.

Manuals: C-14836, C-15627, C-16242

C44I

Aug 2016 to Jan 2024 manuals. IPI version run by the Proflame 2 remote system (TMFSLA transmitter). The manual sends C44ID owners to the separate Dexen user manual for remote operation.

Manuals: C-14837, C-15628, C-16243

C44I-3

Apr 2025 to Jan 2026. IPI with the Proflame 2 remote and controller. Remote operation is in the C-Series User Manual.

Manuals: C-17218, C-17221

C44I-4

Jan 30, 2026 onward. Current IPI version with the Proflame 2 system (TMFSLA transmitter). Remote operation is in the C-Series User Manual.

Manuals: C-17451, C-17221

C44ID (Dexen remote)

The C44I manuals send C44ID owners to the separate Dexen user manual supplied for remote operation and parts, and the C-Series User Manual refers C-Series troubleshooting to the Dexen user manual supplied. The Dexen remote is grey with an orange screen; the Proflame 2 transmitter is black with a blue screen.

Manuals: C-16243, C-17218, C-17221, C-16359

Find your model and serial number: Rotate the safety screen upward or remove it. The rating label and lighting instructions hang on a chain inside the cabinet, on the left side near the front. Don't remove them. The label carries the model and serial number you need for parts and warranty. (Enviro C-17451, p. 7)

Diagram of an Enviro C44 showing where the rating label with the model and serial number is: Rotate the safety screen up or remove it. The rating label hangs on a chain inside the cabinet, on the left side near the front.
Where to find the Enviro C44 rating label. Our diagram, based on Enviro C-17451 p. 7.
Chart of Enviro C44 versions: C44 (millivolt), C44I, C44I-3, C44I-4, C44ID (Dexen remote), with what sets each one apart.
Enviro C44 versions at a glance. Our chart, from the Enviro manuals listed below.

Enviro C44 owner's and installation manuals

Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.

  • C44I-4 Owner's Manual R00

    C-17451 rev R00 · Jan 30, 2026 – Present · 64 pages · Current

    PDF
  • C-Series User Manual

    C-17221 · Apr 4, 2025 – Present · 14 pages · Current

    PDF
  • Dexen System User Manual R3

    C-16359 rev R3 · Current · 12 pages · Current

    PDF
Older Enviro C44 manuals (16)
  • C44I-3 Owner's Manual R01

    C-17218 rev R01 · Apr 4, 2025 – Jan 29, 2026

    PDF
  • Cool Surface System Front Vent Instruction Manual R3

    C-16411 rev R3 · Apr 1, 2022 – Apr 3, 2025

    PDF
  • C44 Owner's Manual R03

    C-16242 rev R03 · Dec 1, 2021 – Dec 31, 2021

    PDF
  • C44I Owner's Manual R04

    C-16243 rev R04 · Dec 1, 2021 – Jan 31, 2024

    PDF
  • C44 Owner's Manual R01

    C-16242 rev R01 · Jun 1, 2021 – Dec 1, 2021

    PDF
  • C44I Owner's Manual R01

    C-16243 rev R01 · May 1, 2021 – Dec 1, 2021

    PDF
  • Cool Surface System Front Vent Instruction Manual R3

    C-15843 rev R3 · Sep 1, 2019 – Apr 1, 2022

    PDF
  • Cool Surface System Side Vent Instruction Manual R3

    C-15844 rev R3 · Sep 1, 2019 – Apr 3, 2025

    PDF
  • C44 Owner's Manual

    C-15627 · Nov 29, 2018 – June 1, 2021

    PDF
  • C44I Owner's Manual

    C-15628 · Nov 29, 2018 – May 1, 2021

    PDF
  • Cool Surface System Side Vent Instruction Manual R01

    C-15196 rev R01 · Oct 10, 2017 – Sept 1, 2019

    PDF
  • Cool Surface System Front Vent Instruction Manual R1

    C-15204 rev R1 · Oct 10, 2017 – Sept 1, 2019

    PDF
  • C-Series HDK Manual

    C-15118 · Apr 3, 2017 – Oct 10, 2017

    PDF
  • Linear HDK Manual for 50-3213

    C-14984 · Dec 13, 2016 – Apr 3, 2017

    PDF
  • C44I Owner's Manual

    C-14837 · Aug 1, 2016 – Nov 29, 2018

    PDF
  • C44 Owner's Manual

    C-14836 · Aug 1, 2016 – Nov 29, 2018

    PDF

Can't open a link? Enviro lists every version on its manuals pages: Enviro C44 manuals, Enviro C60 manuals, Enviro C60 Tall manuals.

Enviro C44 parts list, with part numbers

From the parts lists in the Enviro C44 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.

C44I-4 (Enviro C-17451, p. 62)

RefPartPart #Our store
1C44 pan burner with pilot shield, N/C50-3567$58.75 CAD →
2C44 door complete50-3284Request it
3C44-3 safety screen complete50-4704Request it
4C44 clear view screen only50-3267$214.75 CAD →
5C44 Borderview surround, powder coated (grey)option50-3200$614.18 CAD →
5C44 Borderview surround, nickel platedoption50-3210Request it
6C44 door glass with gasket50-3285Request it
7S.I.T. 885 valve with NG stepper motor50-2682$270.00 CAD →
8Proflame 2 IFC with 7-day shutdown50-4103$330.77 CAD →
9IPI NG pilot assembly (2021)50-4058$120.00 CAD →
–IPI LP pilot thimble50-4080$22.00 CAD →
10C44 tray with glass bezel (glass beads and vermiculite)50-3214Request it
11C44 halogen light kitoption50-3211Request it
12C44 IPI dual convection fan kitoption50-3760Request it
13C44 fluted linersoption50-3206$832.36 CAD →
13C44 ledgestone linersoption50-3207$881.45 CAD →
13C44 porcelain linersoption50-3208$568.36 CAD →
14C44 ultra high definition driftwood log setoption50-3209$783.27 CAD →
–C44 high definition rock setoption50-3286Request it
–C44 black glass beadsoption50-3215$269.45 CAD →
–C44I LP to NG fuel conversion kitoption50-3271Request it
–C44I NG to LP fuel conversion kitoption50-3270Request it
–Proflame 2 IFC wire harness (0.584.924)50-3030Request it
–Proflame 2 transmitter (TMFSLA)50-3265$185.45 CAD →
–C44I owner's manual50-3282Request it
–Replacement fuse, 3 A50-3289Request it
–C44 glass bezel50-3288Request it
–C44 vermiculite (3 cups)50-3287Request it
–35 W halogen bulb50-3291$15.00 CAD →
–C/G Series power vent kitoption50-3884$2,018.40 CAD →
–Metallic black touch-up paint, 12 oz canPAINT-12-MBRequest it

Enviro C44 questions, answered from the manual

Where is the serial number on an Enviro C44?

On the rating label. Rotate the safety screen upward or remove it; the rating label and lighting instructions hang on a chain inside the cabinet, on the left side near the front. Don't remove them. The label has the model and serial number you need for parts and warranty. The C60 and C60 Tall labels are in the same place.

Source: Enviro C-17451, p. 7; C-17470, p. 7; C-16998, p. 7

Which C44 manual do I need?

Check the model code on the rating label. C44I is the model run by the Proflame 2 remote system. For a C44I-4 use C-17451; for the C44I-3 use C-17218. Enviro lists the C-Series User Manual C-17221, which covers Proflame 2 remote operation, alongside both. A C44 without the I is the millivolt model: the pilot flame powers the gas control, the pilot is lit with a piezo ignitor, and the fireplace must be wired to a wall switch or thermostat. It is covered by the archived C44 manuals up to December 2021. Pick the manual whose dates cover your install.

Source: Enviro C-17451, p. 9; C-16242, p. 9; C-16242, p. 41

How do I pair the Proflame 2 remote to my C44 or C60?

Initialize the system the first time you use it and after you replace batteries, using the red reset button on the front right corner of the integrated fireplace controller (IFC). Enviro says to turn off the main gas supply to the fireplace before removing or reinserting the IFC batteries.

  1. Install four AA batteries in the IFC battery holder, matching the polarity marked on the holder. (C-17221, p. 9)
  2. Press the reset button on the IFC marked SW1. The IFC beeps three times when it is ready to pair. (C-17221, p. 9)
  3. With the three AAA batteries in the remote, press its ON button. (C-17221, p. 9)
  4. The IFC beeps four times to confirm it has accepted the remote. The system is now initialized. (C-17221, p. 9)

Source: Enviro C-17221, p. 7; C-17221, p. 8; C-17221, p. 9

My C44 remote stopped working. How do I reset it?

Start with the batteries. A battery icon on the remote's screen means its batteries are low. The C-Series manual says the IFC stops beeping when it gets an ON/OFF command if its own four AA batteries are low; after replacing them, initialize the system again. If the fireplace is locked out, reset the IFC as below.

  1. Replace the batteries in the remote. (C-17451, p. 60)
  2. Press ON/OFF on the remote to turn the system off, wait about 2 seconds and press ON/OFF again. (C-17451, p. 60)
  3. Or, in manual flame mode, press the down arrow until the screen shows OFF, wait about 2 seconds and press the up arrow. The ignition sequence starts. (C-17451, p. 60)
  4. If it is still locked, turn the remote off, disconnect the main power for a few seconds and reconnect it. Wait about 2 seconds and press the reset button on the IFC. (C-17451, p. 60)

Source: Enviro C-17221, p. 11; C-17451, p. 60

How do I use the C44 remote as a thermostat?

Press the THERMOSTAT key. The screen shows the thermostat ON and the set temperature; change it with the UP/DOWN keys. Press THERMOSTAT until SMART appears for the smart thermostat, which turns the flame down as the room gets close to the set temperature. In manual mode the remote has six flame levels on the UP/DOWN keys.

Source: Enviro C-17221, p. 10

Why does my C44 pilot stay on?

The fireplace is in continuous pilot (CPI) mode. With the fireplace off, press MODE until the CPI icon shows. The up arrow selects continuous pilot and the down arrow returns to intermittent pilot (IPI); the IFC beeps once to confirm. Enviro recommends CPI in winter when it is below 50 °F (10 °C) outside: it keeps the chimney warm for updraft at ignition and cuts condensation on the glass.

Source: Enviro C-17221, p. 9

How do I clean the C44 glass?

Condensation on a cold start is normal, and the first paint cure can leave a film. Clean the glass about two weeks after installation, then usually no more than two or three times a season, and only when the fireplace is cold. Use a mild glass cleaner and a soft cloth: abrasive cleaners damage the glass and painted surfaces. If the Cool Surface System has been activated, don't put the discharge accelerator back.

  1. Let the fireplace cool completely. Don't touch or remove the glass door unless it is cold. (C-17451, p. 12)
  2. Grab the safety screen with both hands at the bottom, lift it up off its four mounting brackets and pull it out. (C-17451, p. 11)
  3. Remove the discharge accelerator above the door, then undo the 4 upper bolts with a 3/8" socket and rotate the door outward. (C-17451, p. 12)
  4. Check that the gasket on the back of the glass is attached and intact. (C-17451, p. 10)
  5. Clean the glass with a mild glass cleaner and a soft cloth. (C-17451, p. 10)
  6. Refit the door in reverse order. Don't over-tighten the bolts or they may strip. (C-17451, p. 12)

Source: Enviro C-17451, p. 10; C-17451, p. 12

The C44 glass is cracked. What do I need?

Stop using the fireplace. Don't run it with the glass removed, cracked or broken. The glass is high-temperature ceramic and must be a factory replacement bought from an Enviro dealer, removed and fitted by a licensed or qualified service person. The C44I-4 parts list gives 50-3285 for the door glass with gasket and 50-3284 for the complete door.

Source: Enviro C-17451, p. 10; C-17451, p. 62

Why does my new C44 smoke and smell?

The first burn cures the paint, logs, gasket material and other products used in manufacturing. Run it on high, with the fan off if fitted, for the first 4 hours, and open a window or door because the smoke can irritate some people. Then turn the fireplace off, including the pilot, let it go cold, take off the glass door and clean the glass with a gas fireplace glass cleaner.

Source: Enviro C-17451, p. 6

Can I mount a TV above a C44?

Yes, with protection from the heat. The installation section says the Cool Surface System (CSS) should be activated or an optional front or side CSS kit installed, and that a recess, a mantel or both is needed. That work is in the qualified-installers-only section, so have your installer plan it. In Enviro's tests temperatures stayed at or below 150 °F (65 °C) in a 5" deep recess. Leave 2" around the sides and top of the TV. The minimum height from the base of the fireplace to the bottom of the TV is 45.75" with a mantel (at least an 8" mantel is highly recommended) or 47.00" with a recess. Check your TV maker's maximum operating temperature and confirm temperatures on site. The dual convection fan kit can't be used with the CSS.

Source: Enviro C-17451, p. 36; C-17451, p. 20

Enviro C60 manuals, parts list and FAQ

The C60 is the larger C-Series direct vent gas fireplace, and the C60I-T is its tall version. The current manuals are C-17470 (C60I-4) and C-16998 (C60I-T). The C60I-4 uses the C-Series User Manual C-17221 for remote operation, shared with the C44; the C60I-T manual has its own Proflame 2 section. The Cool Surface System and HDK manuals listed for the C60 are in the C44 document list above.

Enviro C60 manuals

  • C60I-4 Owner's Manual R00

    C-17470 rev R00 · Feb 26, 2026 – Present · 64 pages · Current

    PDF
  • C60I-T (C60 Tall) Owner's Manual R03

    C-16998 rev R03 · Feb 1, 2024 – Present · 60 pages · Current

    PDF
Older Enviro C60 manuals (11)
  • C60I-3 Owner's Manual R01

    C-17215 rev R01 · Mar 10, 2025 – Feb 26, 2026

    PDF
  • C60I Owner's Manual R04

    C-16990 rev R04 · Feb 1, 2024 – Mar 9, 2025

    PDF
  • C60I-T (C60 Tall) Owner's Manual

    C-16695 · Apr 14, 2023 – Jan 31, 2024

    PDF
  • C60 Owner's Manual R03

    C-16244 rev R03 · Dec 1, 2021 – Dec 31, 2021

    PDF
  • C60I Owner's Manual R03

    C-16245 rev R03 · Dec 1, 2021 – Jan 31, 2024

    PDF
  • C60I Owner's Manual R01

    C-16245 rev R01 · Jun 1, 2021 – Dec 1, 2021

    PDF
  • C60 Owner's Manual R01

    C-16244 rev R01 · Jun 1, 2021 – Dec 1, 2021

    PDF
  • C60 Owner's Manual

    C-15674 · Jan 2, 2020 – June 1, 2021

    PDF
  • C60I Owner's Manual

    C-15675 · Jan 2, 2020 – June 1, 2021

    PDF
  • C60I Owner's Manual

    C-15044 · Apr 3, 2017 – Feb 1, 2020

    PDF
  • C60 Owner's Manual

    C-15043 · Apr 3, 2017 – Feb 1, 2020

    PDF

Enviro C60 key specs

Gas input, natural gas (C60I)
34,000 to 51,000 BTU/h (C-17470, p. 49)
Gas input, propane (C60I)
39,500 to 51,000 BTU/h (C-17470, p. 49)
Manifold pressure
3.6" W.C. natural gas, 10.0" W.C. propane (C-17470, p. 49)
Gas connection
3/8" male NPT on a certified flex line, right side (C-17470, p. 49)
Venting
Direct vent, 5" exhaust / 8" intake co-axial; at least 24" vertical and a 90° elbow before going horizontal; up to 40 ft vertical (C-17470, p. 37)
Electrical
Hard-wired power, with a four-AA battery pack as backup (C-17470, p. 51)
Remote
Proflame 2, three AAA batteries, 315 MHz (C-16998, p. 10)
Optional fan kit (C60I)
IPI dual convection fan kit 50-3760, six speeds from the remote (C-17470, p. 51)
Optional fan kit (C60I-T)
C60 IPI dual convection fan kit 50-4173, six speeds from the remote (C-16998, p. 49)

Enviro C60 parts list

C60I-4 (Enviro C-17470, p. 62)

RefPartPart #Our store
1C60 pan burner with pilot shield, N/C50-3568$221.67 CAD →
2C60 door complete50-3387Request it
3C60-3 safety screen complete50-4705Request it
4C60 clear view screen only50-3368$324.44 CAD →
5C60 Borderview surround, powder coated (grey)option50-3337$1,088.73 CAD →
5C60 Borderview surround, nickel platedoption50-3341Request it
6C60 door glass with gasket50-3389Request it
7S.I.T. valve with NG stepper motor50-2682$270.00 CAD →
8Proflame 2 IFC with 7-day shutdown50-4103$330.77 CAD →
9IPI NG pilot assembly (2021)50-4058$120.00 CAD →
–IPI LP pilot thimble (2021)50-4080$22.00 CAD →
10C60 tray with glass bezel (glass beads and vermiculite)50-3343Request it
11C60 halogen light kitoption50-3342Request it
12IPI dual convection fan kit (240 CFM combined)option50-3760Request it
–C60 fan only50-3798$114.00 CAD →
13C60 fluted linersoption50-3338$1,087.64 CAD →
13C60 ledgestone linersoption50-3339$1,257.82 CAD →
13C60 porcelain linersoption50-3340Request it
14C60 ultra high definition driftwood log setoption50-3347$965.45 CAD →
–C60 black glass beadsoption50-3344Request it
–C60I LP to NG fuel conversion kitoption50-3346$174.16 CAD →
–C60I NG to LP fuel conversion kitoption50-3345Request it
–C60 glass bezel50-3390Request it
–C60 vermiculite (4 cups)50-3391Request it
–Replacement fuse, 3 A50-3289Request it
–35 W halogen bulb50-3291$15.00 CAD →
–C60I owner's manual50-3393Request it
–C/G Series power vent kitoption50-3884$2,018.40 CAD →
–Metallic black touch-up paint, 12 oz canPAINT-12-MBRequest it

C60I-T (C60 Tall), differences (Enviro C-16998, p. 57)

RefPartPart #Our store
1C60T pan burner with pilot shield, N/C50-4306Request it
2C60T door complete50-4307Request it
3C60T safety screen complete50-4308Request it
4C60T clear view screen only50-4309Request it
5C60T slim line surroundoption50-3994$437.45 CAD →
–C60T Borderview surround, powder coated (grey)option50-3995Request it
6C60T door glass with gasket50-4310Request it
12IPI dual convection fan kit (240 CFM combined)option50-4173Request it
13C60T fluted linersoption50-3991Request it
–C60T ledgestone linersoption50-3992Request it
–C60T black enamelled linersoption50-3993$1,326.55 CAD →
–C60T black glass linersoption50-4259$2,109.82 CAD →
–C60 Tall IPI LP to NG fuel conversion kitoption50-4369Request it
–C60 Tall IPI NG to LP fuel conversion kitoption50-4368$530.18 CAD →
–C60T owner's manual50-4343Request it

Enviro C60 questions

Which C60 manual do I need?

Check the model code on the rating label, which hangs on a chain inside the cabinet on the left side near the front, behind the safety screen. C60I is the model with the Proflame 2 remote: the current C60I-4 manual is C-17470, with remote operation in the C-Series User Manual C-17221. C60I-T is the C60 Tall, covered by C-16998. A C60 without the I is the millivolt model with a piezo ignitor, covered by the archived C60 manuals up to December 2021.

Source: Enviro C-17470, p. 7; C-17470, p. 9; C-16998, p. 9; C-16244, p. 9; C-16244, p. 41

How much heat does the C60 put out?

The C60I and C60I-T are rated for 34,000 to 51,000 BTU/h input on natural gas and 39,500 to 51,000 BTU/h on propane. The C44I is smaller, at 23,250 to 38,000 BTU/h on natural gas.

Source: Enviro C-17470, p. 49; C-16998, p. 47; C-17451, p. 49

Can I add fans to a C60?

Yes. The C60I takes the optional IPI dual convection fan kit 50-3760 and the C60I-T takes 50-4173. Either can go in before or after the fireplace is installed. The fans run from the remote, with six speeds. All electrical connections must be made by a certified electrician. On the C60I the fan kit can't be used together with the Cool Surface System.

Source: Enviro C-17470, p. 51; C-16998, p. 49; C-17470, p. 20

Can I convert a C60 from natural gas to propane?

Yes, with the certified conversion kit, installed by a qualified service agency only. The C60I kit holds the burner orifice, the pilot orifice, a stepper regulator with hardware, instructions and two conversion labels. The parts lists give 50-3345 (NG to LP) and 50-3346 (LP to NG) for the C60I, and 50-4368 (NG to LP) and 50-4369 (LP to NG) for the C60 Tall.

Source: Enviro C-17470, p. 14; C-17470, p. 62; C-16998, p. 18; C-16998, p. 57