The current Enviro C34 manuals are C-17471 (C34I-4 owner's and installation manual) and C-17221 (C-Series User Manual, the Proflame 2 remote instructions), both free PDFs from enviro.com. Older C34I fireplaces are covered by the archived C34I and C34I-3 manuals, and a C34 without the I is the millivolt model, covered by archived manuals up to December 2021. The rating label with the serial number hangs on a chain inside the cabinet, left side at the front, behind the safety screen.
Owner's manuals for every Enviro C34 and C34I version since 2017, the C-Series remote and accessory manuals, the factory parts lists with part numbers, key specs, and answers to common C34 questions, each taken from the official Enviro manual with the page number.
Last updated · From Enviro docs C-17471 rev R00, C-17221, C-16983 rev R05 and C-16241 rev R04 · Answers drafted from the manuals; staff review pending
C34 (millivolt)
Apr 2017 to Dec 2021 manuals. SIT Nova millivolt valve: the pilot flame generates the electricity to run the main burner, so it works without household power, which is only needed for the optional fan or light kit. The pilot is lit by hand with a piezo ignitor, and the fireplace must be wired to a wall switch or thermostat. An optional remote or cordless wall thermostat can be added.
Manuals: C-16241, C-15677, C-15041
C34I
Apr 2017 to Mar 2025 manuals. Intermittent pilot ignition (IPI) run by the Proflame 2 remote system, with hard-wired power and a four-AA battery backup.
Manuals: C-16983, C-16240, C-15678, C-15042
C34ID (Dexen remote)
The C34I manuals from December 2021 to March 2025 also cover the C34ID and send its owners to the separate Dexen user manual supplied for remote operation, wiring, troubleshooting and replacement parts. Enviro does not list that Dexen manual on the C34 page.
Manuals: C-16983, C-16240
C34I-3
Mar 2025 to Feb 2026. IPI with the Proflame 2 remote and controller. Remote operation is in the C-Series User Manual.
Manuals: C-17217, C-17221
C34I-4
Feb 26, 2026 onward. Current IPI version with the Proflame 2 system. Remote operation is in the C-Series User Manual. The manual covers activating the built-in Cool Surface System (CSS) or converting the cabinet for the ducted front or side vent CSS kits.
Manuals: C-17471, C-17221

Sale price $244.47 CAD Regular price $268.99 CAD

Sale price $558.55 CAD Regular price $614.99 CAD

Sale price $330.77 CAD Regular price
Find your model and serial number: Rotate the safety screen upward or remove it. The rating label and lighting instructions are on plates hanging on a length of chain inside the cabinet, on the left side at the front. Don't tamper with or remove them. The label carries the model-specific serial number you need for warranty. (Enviro C-17471, p. 7)
Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
C34I-4 Owner's Manual R00
C-17471 rev R00 · Feb 26, 2026 – Present · 64 pages · Current
C-Series User Manual
C-17221 · Mar 17, 2025 – Present · 14 pages · Current
C34I-3 Owner's Manual R01
C-17217 rev R01 · Mar 17, 2025 – Feb 25, 2026
C34I Owner's Manual R05
C-16983 rev R05 · Feb 1, 2024 – mar 16, 2025
Cool Surface System Front Vent Instruction Manual R3
C-16411 rev R3 · Apr 1, 2022 – Present
C34I Owner's Manual R04
C-16240 rev R04 · Dec 1, 2021 – Feb 1, 2024
C34 Owner's Manual R04
C-16241 rev R04 · Dec 1, 2021 – Dec 31, 2021
C34 Owner's Manual R02
C-16241 rev R02 · May 1, 2021 – Dec 1, 2021
C34I Owner's Manual R02
C-16240 rev R02 · May 1, 2021 – Dec 1, 2021
C34 Owner's Manual R01
C-15677 rev R01 · Feb 1, 2020 – May 1, 2021
C34I Owner's Manual R01
C-15678 rev R01 · Feb 1, 2020 – May 1, 2021
Cool Surface System Front Vent Instruction Manual R3
C-15843 rev R3 · Sep 1, 2019 – Apr 1, 2022
Cool Surface System Side Vent Instruction Manual R3
C-15844 rev R3 · Sep 1, 2019 – Present
Cool Surface System Front Vent Instruction Manual R1
C-15204 rev R1 · Oct 10, 2017 – Sept 1, 2019
Cool Surface System Side Vent Instruction Manual R01
C-15196 rev R01 · Oct 10, 2017 – Sept 1, 2019
C-Series HDK Manual
C-15118 · Apr 3, 2017 – Oct 10, 2017
C34 Owner's Manual
C-15041 · Apr 3, 2017 – Feb 1, 2020
C34I Owner's Manual
C-15042 · Apr 3, 2017 – Feb 1, 2020
Can't open a link? Enviro lists every version on its manuals pages: Enviro C34 manuals.
From the parts lists in the Enviro C34 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | C34 pan burner | 50-3379 | Request it |
| 2 | C34 door complete | 50-3380 | Request it |
| 3 | C34 safety screen complete | 50-4703 | Request it |
| 4 | C34 clear view screen only | 50-3367 | $244.47 CAD → |
| 5 | C34 Borderview surround, powder coated (gray)option | 50-3325 | $558.55 CAD → |
| 5 | C34 Borderview surround, antique copperoption | 50-3364 | Request it |
| 6 | C34 door glass with gasket | 50-3394 | Request it |
| 7 | S.I.T. 885 valve with NG stepper motor | 50-1421 | Request it |
| 8 | Proflame 2 IFC with 7-day shutdown | 50-4103 | $330.77 CAD → |
| 9 | PSE pilot assembly, intermittent pilot (2021) | 50-4058 | $120.00 CAD → |
| 10 | C34 glass bezel base with vermiculite | 50-3332 | Request it |
| 11 | C34 halogen light kitoption | 50-3331 | Request it |
| 12 | IPI dual convection fan kit (240 CFM combined)option | 50-3760 | Request it |
| 13 | C34 fluted linersoption | 50-3326 | $818.67 CAD → |
| 13 | C34 ledgestone linersoption | 50-3328 | $727.64 CAD → |
| 13 | C34 porcelain linersoption | 50-3329 | $440.73 CAD → |
| 14 | C34 ultra high definition driftwood log setoption | 50-3336 | Request it |
| – | C34 black glass mediaoption | 50-3333 | Request it |
| – | SIT NG to LP conversion (stepper motor only)option | 50-3753 | $187.20 CAD → |
| – | IPI LP to NG conversion (stepper motor only)option | 50-3870 | $115.00 CAD → |
| – | C34 glass bezel | 50-3853 | Request it |
| – | C34 vermiculite (2 cups) | 50-3383 | Request it |
| – | Replacement fuse, 3 A | 50-3289 | Request it |
| – | 35 W halogen bulb | 50-3291 | $15.00 CAD → |
| – | C34I owner's manual | 50-3385 | Request it |
| – | Metallic black touch-up paint, 12 oz can | PAINT-12-MB | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | C34 pan burner with pilot shield, N/C | 50-3566 | $92.57 CAD → |
| 3 | C34 safety screen complete | 50-3381 | Request it |
| 5 | C34 Borderview surround, nickel platedoption | 50-3330 | Request it |
| 7 | S.I.T. 885 valve with NG stepper motor | 50-2682 |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | C34 pan burner with pilot shield, N/C | 50-3566 | $92.57 CAD → |
| 2 | C34 door complete | 50-3380 | Request it |
| 3 | C34 safety screen complete | 50-3381 | Request it |
| 4 | C34 clear view screen only | 50-3367 | → |
On the rating label. Rotate the safety screen upward or remove it: the rating label and lighting instructions are on plates hanging on a length of chain inside the cabinet, on the left side at the front. Don't tamper with or remove them. The label carries the model-specific serial number you need for warranty. Your installer should also have recorded the model and serial number on the installation data sheet at the back of the manual.
Source: Enviro C-17471, p. 7; C-17471, p. 63
Check the model code on the rating label. C34I is the model with intermittent pilot ignition and the Proflame 2 remote. For a C34I-4 use C-17471, and for a C34I-3 use C-17217; Enviro lists the C-Series User Manual C-17221, which covers Proflame 2 remote operation, alongside both. Earlier C34I fireplaces are covered by the archived C34I manuals from April 2017 to March 2025, the last being C-16983. The C34ID has the Dexen remote: the C34I manuals send C34ID owners to the separate Dexen user manual supplied for remote operation, wiring, troubleshooting and parts. A C34 without the I is the millivolt model: the pilot flame powers the gas valve, the pilot is lit by hand with a piezo ignitor and the fireplace must be wired to a wall switch or thermostat. It is covered by the archived C34 manuals up to December 2021.
Source: Enviro C-17471, p. 8; C-17221, p. 7; C-16983, p. 10; C-16983, p. 54; C-16983, p. 56; C-16241, p. 9; C-16241, p. 41
Initialize the system the first time you use it and after you replace batteries, using the red reset button on the front right corner of the integrated fireplace controller (IFC). Enviro says to turn off the main gas supply to the fireplace before removing or reinserting the IFC batteries. These steps are in the C-Series User Manual that Enviro lists with the C34I-3 and C34I-4.
Source: Enviro C-17221, p. 7; C-17221, p. 8; C-17221, p. 9
Start with the batteries. A battery icon on the remote's screen means its batteries are low. The IFC gives no beep when it receives an ON/OFF command if its own four AA batteries are low; after replacing them, initialize the system again. If the fireplace is locked out, reset the IFC as below. A C34ID with the Dexen remote is covered by its own Dexen user manual instead.
Source: Enviro C-17221, p. 11; C-17471, p. 59; C-16983, p. 54
The fireplace is in continuous pilot (CPI) mode. With the fireplace off, press MODE until the CPI icon shows. The up arrow selects continuous pilot and the down arrow returns to intermittent pilot (IPI); the IFC beeps once to confirm. Enviro recommends CPI in winter when it is below 50°F (10°C) outside: it keeps the chimney warm for updraft at ignition and keeps the firebox warm, which cuts condensation on the glass.
Source: Enviro C-17221, p. 9
The C34I needs a hard-wired power connection to operate, with a battery pack of four AA batteries in case power is lost. The Proflame 2 controller runs mainly on 120 VAC and can run off those batteries for shorter periods; when they are low it gives no beep when you press ON/OFF. The older millivolt C34 runs without external electrical power: the pilot flame generates the electricity to operate the main burner, and power is only needed for the optional fan kit or light kit.
Source: Enviro C-17471, p. 51; C-17221, p. 8; C-17221, p. 11; C-16241, p. 41; C-16241, p. 42
Condensation on a cold start is normal, and the first paint cure can leave a film. Clean the glass about two weeks after installation, then usually no more than two or three times a season, and only when the fireplace is cold. Use a mild glass cleaner and a soft cloth: abrasive cleaners damage the glass and painted surfaces. If the Cool Surface System has been activated, don't put the discharge accelerator back.
Source: Enviro C-17471, p. 10; C-17471, p. 11; C-17471, p. 12
Stop using the fireplace. Don't run it with the glass removed, cracked or broken. The glass is high-temperature ceramic and must be a factory replacement bought from an Enviro dealer, removed and fitted by a licensed or qualified service person. The C34I-4 parts list gives 50-3394 for the door glass with gasket and 50-3380 for the complete door; the archived C34 and C34I lists give the same numbers.
Source: Enviro C-17471, p. 10; C-17471, p. 61; C-16241, p. 51; C-16983, p. 56
Yes, with the certified conversion kit, installed by a qualified service agency only. The C34I kit holds the burner orifice (#37 DMS natural gas or #52 DMS propane), the pilot orifice, a stepper regulator with hardware, an instruction sheet and two conversion labels. The installer swaps the orifices, replaces the stepper motor on the valve, leak-tests, checks the gas pressures and puts the conversion label on or near the rating label. The C34I-4 parts list gives the stepper motors alone as 50-3753 (NG to LP) and 50-3870 (LP to NG). For the millivolt C34 the archived parts list gives the kits 50-3370 (NG to LP) and 50-3371 (LP to NG).
Source: Enviro C-17471, p. 14; C-17471, p. 15; C-17471, p. 61; C-16241, p. 51
Yes, with protection from the heat. The installation section says a recess, a mantel or both is needed, and that the Cool Surface System (CSS) should be activated or an optional front or side CSS kit installed. In Enviro's tests temperatures did not exceed 150°F (65°C) in a 5" deep recess. Leave 2" around the sides and top of the TV. The minimum height from the base of the fireplace to the bottom of the TV is 45.75" with a mantel (at least an 8" mantel is highly recommended) or 47.00" with a recess. Check your TV maker's maximum operating temperature and confirm temperatures on site. This is work for a qualified installer: the dual convection fan kit can't be used with the CSS, and a non-ducted CSS needs a minimum 96" ceiling height.
Source: Enviro C-17471, p. 36; C-17471, p. 20; C-17471, p. 25
The first burns cure the paint, logs, gasket material and other products used in manufacturing. Run it on high, with the fan off if fitted, for the first 4 hours, and open a window or door because the smoke can irritate some people; the installation section adds that curing can take upwards of 10 hours. Then turn the fireplace off, including the pilot, let it go cold, take off the glass door and clean the glass with a gas fireplace glass cleaner.
Source: Enviro C-17471, p. 6; C-17471, p. 24
| 8 | Proflame 2 IFC with 7-day shutdown | 50-3791 | $342.06 CAD → |
| – | IPI LP pilot thimble (2021) | 50-4080 | $22.00 CAD → |
| – | C34I fan only | 50-3798 | $114.00 CAD → |
| – | C34I LP to NG fuel conversion kitoption | 50-3334 | Request it |
| – | C34I NG to LP fuel conversion kitoption | 50-3335 | Request it |
| – | C34 glass bezel (glass only) | 50-3382 | Request it |
| – | C-Series Cool Surface Systemoption | 50-3463 | Request it |
| – | C/G Series power vent kitoption | 50-3884 | $2,018.40 CAD → |
| 5 | C34 Borderview surround, powder coated (gray)option | 50-3325 | $558.55 CAD → |
| 5 | C34 Borderview surround, antique copperoption | 50-3364 | Request it |
| 5 | C34 Borderview surround, nickel platedoption | 50-3330 | Request it |
| 6 | C34 door glass with gasket | 50-3394 | Request it |
| 7 | S.I.T. Nova valve, convertible | 50-1421 | Request it |
| 8 | 3-way Nova pilot assembly (PSE-NA479) | 50-4083 | $130.00 CAD → |
| 9 | S.I.T. piezo ignitor | EC-023 | $44.25 CAD → |
| 10 | Burner switch | EC-026 | $30.00 CAD → |
| 11 | Control panel and decal | 50-2989 | Request it |
| 12 | Fan controller (69.5 V), 115 V, with knob | EC-039A | $119.51 CAD → |
| 13 | 120 ceramic fan temperature sensor | EC-001 | $77.79 CAD → |
| 14 | C34 Nova dual convection fan kitoption | 50-3353 | $641.00 CAD → |
| – | C34 fan only | 50-3798 | $114.00 CAD → |
| 15 | C34 ultra high definition driftwood log setoption | 50-3336 | Request it |
| 16 | C34 fluted linersoption | 50-3326 | $818.67 CAD → |
| 16 | C34 ledgestone linersoption | 50-3328 | $727.64 CAD → |
| 16 | C34 porcelain linersoption | 50-3329 | $440.73 CAD → |
| 17 | C34 halogen light kitoption | 50-3331 | Request it |
| 18 | C34 glass bezel (glass media and vermiculite) | 50-3332 | Request it |
| – | Heat distribution / TV kitoption | 50-3463 | Request it |
| – | C34 black glass mediaoption | 50-3333 | Request it |
| – | C34 LP to NG fuel conversion kitoption | 50-3371 | Request it |
| – | C34 NG to LP fuel conversion kitoption | 50-3370 | Request it |
| – | C34 glass bezel (glass only) | 50-3382 | Request it |
| – | C34 vermiculite (2 cups) | 50-3383 | Request it |
| – | Replacement fuse, 3 A | 50-3289 | Request it |
| – | 35 W halogen bulb | 50-3291 | $15.00 CAD → |
| – | C34 owner's manual | 50-3384 | Request it |
| – | C/G Series power vent kitoption | 50-3884 | $2,018.40 CAD → |
| – | Metallic black touch-up paint, 12 oz can | PAINT-12-MB | Request it |