Where is the serial number on an Enviro Accent 20?
On the rating label, which is under the firebox, attached to a rectangular metal sheet that is chained to the fireplace. Your installer should also have written the model and serial number on the installation data sheet at the back of the owner's manual.
Source: Enviro C-10235, p. 6; C-10235, p. 29
Which Accent 20 manual do I need?
There is one: C-10235, the Accent 20 BV Owner's Manual, dated June 14, 2004 on its back page. Enviro lists it as archived, without validity dates. It covers the natural gas and propane versions and includes the installation instructions, which are for qualified installers only, and the cast, surround panel and component parts lists. Its own part number is 50-304.
Source: Enviro C-10235, p. 4; C-10235, p. 12; C-10235, p. 26; C-10235, p. 29
How do I light the pilot on an Enviro Accent 20?
The Accent 20 has a standing pilot that you light by hand with the push button piezo spark ignitor. The gas valve has a lockout device, so the pilot cannot be relit until the thermocouple has cooled; allow about 60 seconds. If the knob does not pop up when released, stop and call your service technician or gas supplier; if the pilot will not stay lit after several tries, turn the gas control knob to OFF and call them. To turn the gas off, set the thermostat to its lowest setting, put the burner switch to off, then press the pilot knob in slightly and turn it clockwise to OFF without forcing it.
- Set the thermostat to the lowest setting and turn off all electrical power to the appliance. Set the burner switch, on the top right of the surround panel set, to the middle off position. (C-10235, p. 7)
- Press the pilot gas knob in slightly and turn it clockwise to off. Wait five minutes to clear out any gas, then smell for gas, including near the floor. If you smell gas, stop and follow the safety information on the label. (C-10235, p. 7)
- Find the pilot, between the front and rear burner. Press the pilot knob in slightly and turn it counter-clockwise to PILOT. (C-10235, p. 7)
- Push the knob in fully and hold it, and light the pilot right away with the piezo spark ignitor. Keep the knob pushed in for about 30 seconds after the pilot lights, then release it. (C-10235, p. 7)
- Turn the pilot knob counter-clockwise to on, set the burner switch to on (or to thermostat, if fitted), turn the HI/LO knob or thermostat to the setting you want and turn the electrical power back on. (C-10235, p. 7)
Source: Enviro C-10235, p. 7
How do I open the Accent 20 door and clean the glass?
Clean the glass only when the fireplace is cool, after the first burn, again about two weeks later, then no more than two or three times a season, with a mild glass cleaner and a soft cloth. Abrasive cleaners damage the glass and plated surfaces. Condensation on a cold start is normal, and gas additives can make the glass hazy. Check that the gasket on the back of the glass is attached and intact.
- Turn the fireplace off and wait until it has cooled down. (C-10235, p. 8)
- Open the lower louver panel. (C-10235, p. 8)
- With a 5/16" socket, undo the two bolts at the bottom corners of the door. (C-10235, p. 8)
- Swing the door out, then lift it up and out. (C-10235, p. 8)
- After cleaning, make sure the door is properly fastened before relighting the fireplace. (C-10235, p. 8)
Source: Enviro C-10235, p. 8; C-10235, p. 20
The Accent 20 glass is cracked. What do I need?
Do not run the fireplace with the glass removed, cracked or broken. The glass is a high temperature 5 mm ceramic and needs a factory replacement from an Enviro dealer; no substitute materials are allowed, and Enviro highly recommends that a licensed or qualified service person replace it. The parts list has the glass with gasket, EG20-090, and the window channel tape, EG20-089. New glass goes in with the large bulb of the gasket tape against the unit and the tape joint in a bottom corner, stuck to the door frame with high temperature silicone.
Source: Enviro C-10235, p. 9; C-10235, p. 26
How do I clean the Accent 20 firebox and logs?
At least once a year check that the burner ports are clear and clean and that nothing blocks the pilot; the pilot flame should be blue with little or no yellow on the tips. Once a year, also take the logs out and check them for deterioration or heavy soot; a little soot under the logs is normal. Have the venting examined periodically, preferably by a qualified agency. New embers and rock wool come from an Enviro dealer.
- Remove the door, then take out the logs carefully, as they are very fragile, and lift the embers and rock wool onto a paper towel. (C-10235, p. 9)
- Vacuum the bottom of the firebox, clean the dust off the logs and brick panels and remove any lint from the burner and pilot; a clean 2" paint brush also works. (C-10235, p. 9)
- Check the burner pan for cracking or severe warping, and contact the dealer if you suspect a problem. (C-10235, p. 9)
- Put the logs and embers back as shown in the log set section, reseal the door and relight the pilot following the lighting label. (C-10235, p. 9)
Source: Enviro C-10235, p. 8; C-10235, p. 9; C-10235, p. 18
Why won't my Accent 20 pilot or burner stay lit?
Enviro's troubleshooting table gives these checks. If the pilot will not stay lit: the thermocouple must be tight at the rear of the valve, the pilot flame must fully surround it, and it must read more than 5 mV at the valve, or it should be replaced; if the pilot dies while you hold the knob in, there may be air in the gas line, so bleed the line and check the gas pressure. If the burners will not stay lit: check the gas line pressure, the flame on the thermopile (at least 200 mV with the burner switched on) and the thermostat wiring. An air tight house, or a vacuum from kitchen and bathroom fans, can starve the insert of combustion air: supply make-up air or open a window. Installation and repair should be done by a qualified service person.
Source: Enviro C-10235, p. 20; C-10235, p. 2
How is the Accent 20 vented, and what does the spill switch do?
The Accent 20 is a B-vent insert: it draws combustion and dilution air from the room and is installed only in a solid fuel burning fireplace with a working flue, built of non-combustible material, using a full length chimney liner and rain cap. It vents with 3" aluminum or stainless steel flex vent and/or certified Type B gas vent. A vent safety shutoff (spill switch) at the rear, near the draft hood relief opening, shuts the insert down if combustion products spill; if it trips more than once, have a qualified service technician inspect the venting for blockage or severe down draft. Draft can be checked with smoke at the ⅜" tube between the louvers: suction into the tube means it is drafting properly.
Source: Enviro C-10235, p. 4; C-10235, p. 5; C-10235, p. 13
Can I convert an Accent 20 from natural gas to propane?
Yes, with Enviro's conversion kit, installed by a qualified service technician. The kits are NG to LP EG20-203 and LP to NG EG20-201. Each holds a 50% turn down HI/LO regulator with three T-20 Torx screws, a pilot injector, a main orifice (#45 DMS natural gas or #55 DMS propane), the instructions and conversion labels. The technician swaps the regulator on the front of the gas valve, the pilot injector and the burner orifice, checks that the new regulator knob has only one corner (the mark of a 50% turn down regulator), and fits the S.I.T. sticker and a conversion label on the rating plate.
Source: Enviro C-10235, p. 11; C-10235, p. 26
Can an Accent 20 go in a factory-built fireplace?
Enviro's policy allows the insert in a listed factory-built (zero clearance) fireplace provided removing parts does not weaken its structure, the fireplace is in good condition, nothing is cut, bent or broken (firebricks may be removed), and a permanent label is fixed to the firebox warning that the fireplace may only be operated with a gas insert and that removing the insert and burning solid fuel is prohibited. The parts the manual lists for removal are fire bricks, the smoke shield, the flue damper, glass doors and fire screens.
Source: Enviro C-10235, p. 5
Which surrounds fit the Accent 20?
The parts lists show steel surround panels in three sizes, regular (50-104 black trim, EG20-120 brass trim), oversized (50-105, EG20-122) and four sided (50-106, EG20-130), with trim alone in black, brass or nickel; and a cast iron front and complete surround in eight finishes, from painted (50-146) to Antique Chestnut (50-813). A cast iron surround panel extension trim kit can be bolted to the top or the bottom of the surround. Use only parts specifically approved for this appliance.
Source: Enviro C-10235, p. 24; C-10235, p. 21; C-10235, p. 19; C-10235, p. 2