Manuals & parts · Pellet stove and fireplace insert (discontinued)
Quick answer
The Enviro EF4 is a discontinued pellet stove, made as a freestanding stove and a fireplace insert, and Enviro lists all of its manuals as archived. The last domestic edition is the owner's manual C-10803, dated January 12, 2005, a free PDF from enviro.com with the installation, troubleshooting and parts list; the DIN manuals C-10448 and C-10449 cover the 220-240 V export version. EF4 parts are still sold here, and the rating label is inside the hopper lid (freestanding) or on the hopper cover (insert).
Every EF4 manual Enviro still publishes (domestic owner's manuals from 2003 to 2005 and the DIN owner's and technical manuals), the factory parts list with part numbers, key specs, and answers to common EF4 questions, each taken from the official Enviro manual with the page number. Enviro no longer makes the EF4, but we still sell its parts.
Last updated · From Enviro docs C-10803, C-10448, C-10139, C-10447 and C-10449 · Answers drafted from the manuals; staff review pending
EF4 freestanding (115 V)
Freestanding stove on a pedestal with an ash pan, and the rating label inside the hopper lid. It has a Dial-A-Fire control panel: a start-up switch, a heat output knob (B) and a convection fan knob (A). The domestic owner's manuals cover it together with the insert.
Manuals: C-10803, C-10447, C-10139
EF4 fireplace insert (FPI, 115 V)
Insert for a masonry fireplace, with its own pedestal, surround panels and the control panel mounted in the right surround panel. It has no ash pan, the rating label is on the hopper cover, and it needs a continuous 3" or 4" chimney liner to the top of the chimney.
Manuals: C-10803, C-10447, C-10139
EF4 DIN (220-240 V, 50 Hz)
Export version of the freestanding stove and insert for 220-240 V, 50 Hz power, with its own owner's and technical manuals and 220 V electrical parts (see the DIN parts differences below).
Manuals: C-10448, C-10449
Find your model and serial number: On the freestanding EF4 the rating label is on the inside of the hopper lid; on the fireplace insert it is on the hopper cover. (Enviro C-10803, p. 3)

Sale price $8.85 CAD Regular price $10.00 CAD

Sale price $76.90 CAD Regular price $84.99 CAD

Sale price $166.67 CAD Regular price $183.99 CAD

Official Enviro PDFs, opened from enviro.com so you always get Enviro's own copy.
The Enviro EF4 is discontinued: Enviro lists all of its manuals as archived. We still sell Enviro EF4 parts.
Can't open a link? Enviro lists every version on its manuals pages: Enviro EF4 FS manuals, Enviro EF4 FPI manuals, Enviro legacy manuals.
From the parts lists in the Enviro EF4 manuals. Reference numbers match the manual's parts diagram. A price means we sell it; “Request it” means we can source it for you.
| Ref | Part | Part # | Our store |
|---|---|---|---|
| – | Fan controller knob | EC-040 | $8.85 CAD → |
| – | IEC power cord, 115 V | EC-043 | $76.90 CAD → |
| 1 | Auger motor, 115 V | EF-001 | $166.67 CAD → |
| – | Convection blower insulator (gasket) | EF-006 | $10.99 CAD → |
| – | Combustion main impeller | EF-008 | $93.33 CAD → |
| – | Combustion cooling impeller | EF-009 | Request it |
| 2 | Exhaust temperature sensor, 140 °F (60 °C), ceramic | EF-010 | Request it |
| – | Combustion blower mounting gasket | EF-011 | $53.20 CAD → |
| – | Combustion blower housing gasket | EF-012 | $52.00 CAD → |
| 3 | Fan temperature sensor, 160 °F (71 °C) | EF-013 | $34.00 CAD → |
| 4 | Ignition temperature sensor, 120 °F (49 °C), ceramic | EF-015 | $48.36 CAD → |
| 5 | High limit temperature sensor, 200 °F (93 °C), manual reset | EF-016 | $79.80 CAD → |
| 6 | Vacuum switch, 115 V | EF-017 | $76.36 CAD → |
| – | Silicone hose | EF-018 | $38.00 CAD → |
| – | Aluminum hose barb | EF-019 | $68.10 CAD → |
| 7 | Auger timer control, 115 V (3 sec) | EF-036 | $127.27 CAD → |
| 8 | Power up timer control, 115 V | EF-037 | Request it |
| 9 | Green light, 115 V | EF-041 | $53.20 CAD → |
| 10 | Start up switch | EF-043 | $51.66 CAD → |
| 11 | Fan controller with knob, 115 V | EF-045 | $40.00 CAD → |
| – | Ash pan latch (insert) | EF-060 | Request it |
| 12 | Auger brass bushings (set of 2) | EF-065 | $80.00 CAD → |
| – | Dial-a-fire knob | EF-067 | $49.55 CAD → |
| – | Shoulder bolt, hardened bushing and nut (set of 2) | EF-124 | $69.64 CAD → |
| – | Pellet stove cleaning brush | EF-156 | $36.83 CAD → |
| 13 | Ash pan latch (freestanding) | EF-178 | Request it |
| – | Pedestal and ash pan gasket (10 ft) | EF-208 | $52.00 CAD → |
| 14 | Convection blower, 115 V | EF4i-002 | Request it |
| – | Convection blower impeller | EF4i-004 | Request it |
| 15 | Ignition burn pot | EF4i-021 | Request it |
| 16 | Steel burn pot liner (domestic) | EF4i-024 | Request it |
| – | Auger brass bushing and plate | EF4i-026 | Request it |
| 17 | Door handle (wooden) | EF4i-028 | Request it |
| 18 | Door latch with bolt (includes ferrule and bearing) | EF4i-029 | Request it |
| 19 | Firebox liner with insulation | EF4i-047 | Request it |
| – | Heat exchanger rod | EF4i-051 | Request it |
| – | Door gasket, 3/4" firm round (7 ft) | EF4i-056 | $63.84 CAD → |
| – | Window channel tape | EF4i-058 | Request it |
| 20 | Glass set | EF4i-062 | Request it |
| – | Slider damper spacers | EF4i-063 | Request it |
| – | Slider damper plate | EF4i-064 | Request it |
| 21 | Firebox liner top plate | EF4i-066 | Request it |
| – | Wiring harness | EF4i-071 | Request it |
| – | Pedestal (insert) | EF4i-074 | Request it |
| 22 | Door latch cover and door hinge cover (set of 2) | EF4i-096 | Request it |
| 23 | Back grill | EF4i-097 | Request it |
| 24 | Ash sill | EF4i-103 | Request it |
| 25 | Ash pan with latch | EF4i-105 | Request it |
| 26 | Stove top (freestanding) | EF4i-111 | Request it |
| – | Stove top (insert) | EF4i-114 | Request it |
| – | Owner's manual, domestic | EF4i-118 | Request it |
| 27 | Front grill | EF4i-123 | Request it |
| – | Cabinet side set, left and right (insert) | EF4i-131 | Request it |
| – | Hopper side, left | EF4i-135 | Request it |
| – | Hopper side, right | EF4i-135A | Request it |
| – | Spring for hopper lid (insert) | EF4i-138 | Request it |
| 28 | Pedestal (freestanding) | EF4i-139 | Request it |
| 29 | Cabinet side, left (freestanding) | EF4i-142 | Request it |
| 30 | Cabinet side, right (freestanding) | EF4i-143 | Request it |
| – | Firebox ceramic wool insulation | 20-017 | Request it |
| – | Log setoption | 20-036 | $250.15 CAD → |
| 31 | Cleaning port covers | 20-037 | Request it |
| 32 | Control panel door | 20-040 | Request it |
| 33 | Phase controller, 115 V | 50-312 | $138.84 CAD → |
| 34 | Dial-a-fire, 115 V | 50-313 | Request it |
| 35 | Auger | 50-319 | Request it |
| 36 | Control panel touch latch | 50-323 | $70.22 CAD → |
| 37 | Glass extrusions (set of 2) | 50-483 | Request it |
| 38 | Flush handle (for hopper lid) | 50-523 | Request it |
| 39 | Phase control panel with door, decal, switch and light, 115 V (freestanding) | 50-678 | $139.82 CAD → |
| 39 | Phase control panel with door, decal, switch and light, 115 V (insert) | 50-679 | Request it |
| 40 | IEC power cord inlet socket | 50-713 | Request it |
| 41 | Exhaust blower assembly, 115 V | 50-901 | Request it |
| – | 5/8" ID auger collar with screw | 50-968 | $65.11 CAD → |
| 42 | Ignitor, 300 W, 115 V | 50-1067 | $176.67 CAD → |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 43 | Steel brick liningoption | EF4i-130 | Request it |
| – | Bar set (set of 2), goldoption | EF4i-144 | Request it |
| 44 | Door complete, polished nickeloption | 50-261 | Request it |
| 44 | Door complete, goldoption | EF4i-092 |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 13 | Pin ignitor, 115 V | EF-127 | $300.55 CAD → |
| 32 | Halogen cycle | 20-034 | Request it |
| Ref | Part | Part # | Our store |
|---|---|---|---|
| 1 | Auger motor, 220 V | EF-001-220V | Request it |
| 6 | Vacuum switch, 220 V | EF-017-220V | Request it |
| 7 | Auger timer control, 220 V (3 sec) | EF-036-220V | Request it |
| 8 | Power up timer control, 220 V | EF-037-220V |
On the rating label. On the freestanding EF4 it is on the inside of the hopper lid; on the fireplace insert it is on the hopper cover (the DIN owner's manual says the same for the built-in heater). Your installer should also have recorded the model and serial number on the installation data sheet at the back of the owner's manual. Keep it: the dealer needs the serial number for a warranty claim.
Source: Enviro C-10803, p. 3; C-10448, p. 3; C-10803, p. 37; C-10803, p. 36
The EF4 is discontinued and Enviro lists every EF4 document as archived. For a domestic 115 V EF4, freestanding or insert, the last edition is the owner's manual C-10803, dated January 12, 2005; besides operation and cleaning it has the installation, troubleshooting, wiring diagram and parts list for both versions. Earlier stoves are covered by the September 2004 edition C-10447 and the October 2003 edition C-10139. The 2004 and 2005 parts lists differ in the ignitor: the September 2004 list has a pin ignitor (EF-127), the January 2005 list a 300 W ignitor (50-1067). The DIN owner's manual C-10448 and technical manual C-10449 are for the 220-240 V, 50 Hz export version.
Source: Enviro C-10803, p. 1; C-10803, p. 2; C-10803, p. 37; C-10803, p. 5; C-10803, p. 32; C-10447, p. 31; C-10448, p. 5
Fill the hopper, plug the stove in, press the start-up switch once and set the Dial-A-Fire heat output knob (B) to 12 o'clock until the fire is established, then to the heat you want. Don't hold the start-up switch down: it is a momentary switch and can be damaged. The fan control knob (A) sets the convection blower speed; leave it off at first so the stove heats up quickly. To turn the stove off, turn knob B counter-clockwise until it clicks to OFF: the pellet feed stops and the blowers keep running until the stove has cooled, then it shuts down. Don't unplug it while the combustion fan is running, as smoke may escape.
Source: Enviro C-10803, p. 7; C-10803, p. 26
Wood pellets only, with up to 3% ash: Enviro says any other fuel voids the warranty, burning cordwood is prohibited by law, and you must not burn garbage or flammable fluids. Use pellets that are dry and free of dirt and impurities such as high salt content; Enviro recommends pellets that meet or exceed the PFI standards, which the manual lists as at most 1% fines through a 1/8" screen, 1% ash for premium grade and 3% for standard grade, 8% moisture and about 8200 Btu per pound. High-ash fuel may mean cleaning the stove daily. Store pellets at least 36" (1 m) from the stove, and never put unburned pellets in the ash pan.
Source: Enviro C-10803, p. 3; C-10803, p. 4; C-10803, p. 5
Inspect the burn pot and liner every two to three days, with the stove cold, and check the liner daily for clinkers (hard lumps of sand or other impurities) blocking its holes. A dirty liner can let fuel build up past the liner and up the drop tube, which jams the auger and may lead to pellets burning in the drop tube and hopper. If the fire keeps building up and overflowing the pot, the pellets may be poor or the stove may need cleaning: check for ash build-up and adjust the slider damper. The steel burn pot liner is part EF4i-024.
Source: Enviro C-10803, p. 8; C-10803, p. 3; C-10803, p. 31
The freestanding EF4 has an ash pan under the burner, in the pedestal: unlock the latch on the pedestal cover, pull the pan out and dump the ashes into a metal container stored away from combustibles, and check the ash level every week. The insert has no ash pan, so the ashes must be vacuumed out of the firebox daily. Use a vacuum bag, because the fly ash is very fine and would otherwise blow back into the room, and make sure there are no hot ashes in the firebox, which could start a fire in the vacuum cleaner. Keep disposed ashes in a metal container with a tight-fitting lid on a non-combustible floor until all cinders have cooled, and never put unburned pellets in the ash pan.
Source: Enviro C-10803, p. 9; C-10803, p. 5
Every two to three days: the burn pot and liner, and the exhaust passages, by vacuuming behind the firebox liner plates through the two round cleaning port covers at the bottom of the firebox (open the side panels and loosen, but don't remove, the screw on each cover). Weekly: the ash pan, the ash pan and door gaskets (reglue loose gasket with high-temperature fiberglass gasket glue) and the heat exchanger tubes (with the stove cold, pull the handle under the hopper lid, just above the door, up and down a few times). Twice a year or every 2 tons of fuel: take out the firebox backing and vacuum behind it. Each season: check the fresh air intake, have the exhaust vent inspected at least once a year or after two tons of pellets (Enviro recommends professional cleaning by your dealer), and unplug the stove to vacuum both blowers. Oil the convection blower motor on the right side with two drops of SAE 20 light oil every six months; don't oil the exhaust blower motor, which has sealed bearings. Don't use abrasive cleaners on the stove.
Source: Enviro C-10803, p. 8; C-10803, p. 9; C-10803, p. 10
Twice a year, or every two tons of fuel, take out the firebox backing and vacuum behind it. Do it with the stove cold, and lubricate the firebox screws with penetrating oil before removing them.
Source: Enviro C-10803, p. 8; C-10803, p. 9; C-10803, p. 26
Clean the glass only when the stove is off and the glass is not hot. Use a soft cotton cloth with a mild window cleaner or a gas or wood stove glass cleaner, or a damp paper towel dipped in the fly ash, which is a very mild abrasive. Don't strike the glass or slam the door, and never run the stove with broken glass. Enviro recommends having your dealer replace broken glass: it is high-temperature pyroceramic, held by four glass retainers and refitted with high-temperature fiberglass tape. Substitute materials are prohibited; use only part EF4i-062. On a gold or nickel plated door, wipe off fingerprints with denatured alcohol on a soft cloth before lighting the stove, and never clean the face while it is hot.
Source: Enviro C-10803, p. 5; C-10803, p. 10; C-10803, p. 25
Look at the burn pot liner. Fresh unburned pellets or cigarette-like ash mean the fire went out before the 120 °F (49 °C) temperature sensor shut the stove off: check the slider damper position and turn the Dial-A-Fire up slightly, since poor pellets need slightly higher settings. Partly burned pellets mean the stove shut down for lack of air, low exhaust temperature or a power cut: adjust the slider damper and check whether the stove needs a more complete cleaning. No pellets in the liner means the auger is stopping. One cause is the 200 °F (93 °C) high limit switch, which stops the auger if the hopper gets too hot; your dealer resets it and has to find out why the stove overheated. After a power cut the stove stops and will not restart by itself unless the exhaust is still above 120 °F (49 °C). Enviro says troubleshooting should be done by qualified technicians or installers.
Source: Enviro C-10803, p. 29; C-10803, p. 6; C-10803, p. 26
Sale price $10.99 CAD Regular price $12.99 CAD
| Request it |
| 44 | Door complete, paintedoption | EF4i-094 | Request it |
| 45 | Door cover (door A), paintedoption | 50-169 | Request it |
| 45 | Door cover (door A), goldoption | 50-170 | Request it |
| 45 | Door cover (door A), polished nickeloption | 50-171 | Request it |
| – | Regular surround panel with black trim (insert)option | 50-102 | Request it |
| – | Oversize surround panel with black trim (insert)option | 50-103 | Request it |
| – | Oversize surround panel trim only, black (insert)option | 50-119 | Request it |
| – | Regular surround panel trim only, black (insert)option | 50-120 | Request it |
| – | Oversize surround panel trim only, nickel (insert)option | 50-131 | Request it |
| – | Regular surround panel trim only, nickel (insert)option | 50-132 | Request it |
| – | Regular surround panel trim only, brass (insert)option | EC-051 | Request it |
| – | Oversize surround panel trim only, brass (insert)option | EC-052 | Request it |
| – | Tapped corner bracket (insert)option | EC-053 | Request it |
| – | Regular surround panel (insert)option | EF4i-076 | Request it |
| – | Oversize surround panel (insert)option | EF4i-078 | Request it |
| – | Square oversize surround panel with brass trim (insert)option | EF4i-108 | Request it |
| Request it |
| 9 | Green light, 220 V | EF-041-220V | Request it |
| 11 | Fan controller with knob, 220 V | EF-045-220V | Request it |
| 14 | Convection blower, 220 V | EF4i-002-220V | Request it |
| – | CE power cord, 220 V | 20-010-220V | Request it |
| 30 | Pin ignitor, 220 V | 20-016-220V | Request it |
| 31 | Halogen cycle | 20-034 | Request it |
| 34 | Dial-a-fire, 220 V | 20-043 | Request it |
| 35 | Steel burn pot liner (high ash) | 50-259 | Request it |
| 38 | Phase controller, 220 V | 50-353 | Request it |
| 40 | Phase control panel with door, decal, switch and light, 220 V (freestanding) | 50-486 | Request it |
| 40 | Phase control panel with door, decal, switch and light, 220 V (insert) | 50-494 | Request it |
| – | EMI filter, 220 V | 50-648 | Request it |
| – | Owner's manual, DIN | 50-839 | Request it |
| – | Technical manual, DIN | 50-840 | Request it |
| 42 | Exhaust blower assembly, 220 V | 50-900 | Request it |